The 2916 Indoor/Outdoor Keypad Surface Mount is a digital keyless entry
system designed for access control applications. The keypad is integrated
in a heavy cast vandal resistant housing, designed to be mounted on a
rugged, surface mounting plate and may be mounted in a standard
single-gang electrical box. The indoor/outdoor backlit keys have bright,
easy-to-read graphics.
Up to 500 entry codes, from 1 to 6 digits in length, can be programmed.
They can activate either, or both of the relay outputs. The "anti-
passback" feature prevents using the same code again before the
programmed time elapses.
All system indicators are long-lasting, solid state LEDs. Two indicators
show the status of the entry system. The left indicator lights red to
indicate power, then turns green when access is granted. The right
indicator lights yellow when the keypad is in "lockout" condition (from too
many incorrect code entries). The yellow LED flashes when the keypad is
in programming mode. An internal sounder beeps when each key is
pressed. An internal jumper sets the sounder volume high or low
The SENSE input can be used two ways. If programmed for "door
sense" the input is wired to a normally closed switch on the door to detect
when the door is opened or closed. Forced entry or door ajar situations
can then be detected. Using door sense, the "Auto-relock" feature will
prevent "tailgating" by turning off the Main Relay output immediately
when the door is closed after access has been granted. If the SENSE
input is programmed for "inhibit", the input can be wired to a "service"
switch or automatic timer that will disable the Main Relay when required.
The REQUEST-TO-EXIT input can be wired to a pushbutton to provide
codeless activation of Main Relay, Auxiliary Relay, Output #3 or Output
#4 (programmable).
The ALARM SHUNT output activates when access is granted. This
output can be wired to shunt alarm contacts on the access door/gate to
prevent triggering of an alarm when authorized access occurs.
The 2916 is powered from a 12-24V AC or DC source.
memory retains all entry codes and programming, even without power.
An internal jumper is provided to reset the master code. The Main Relay
has a 5 Amp capacity. The Auxiliary Relay has a 2 Amp capacity. Two
solid state outputs, capable of switching 100 mA to common, are
programmable to signal forced entry, door ajar, lockout, alarm circuit
shunting, request-to-exit, and keypad active conditions.
5/7/2012
INSTALLATION INSTRUCTIONS
2916
The EEPROM
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 ● (800) 325-9995
Installation Instructions

Features

Keypad programmable
·
500 user codes
·
1 to 6 digit user codes
·
4 independent outputs
·
4 independent timers
·
2 Form C relay contacts
·
2 solid state open collector outputs
·
Program entry codes to activate one or
·
two relays
Disable input
·
Door sense input
·
Request-to-exit/enter input
·
Keypad tamper lockout
·
Timed anti-passback
·
Anti-tailgate
·
Two LED status indicators
·
Tactile key feel
·
Audible code entry verification
·
12 or 24V, AC or DC operation
·

SPECIFICATIONS

Mechanical
Dimensions: 3.00" W x 5.75" H x 1.375" D
(1.4375" wall projection)
Electrical
Input Voltage: 12-24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max
Output Ratings
Main Relay: Form "C" 5 Amps @ 28 Volts max
Auxiliary Relay: Form "C" 2 Amp @ 28 Volts max
Type: Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum
Environmental
Temperature: -22°F to 149°F (-30°C to 65°C)
Humidity:5% to 95% non-condensing
2916 Keypad
S-EA00080
Security Door Controls
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2916 and is the answer not in the manual?

Questions and answers

Summary of Contents for hager 2916

  • Page 1 Security Door Controls INSTALLATION INSTRUCTIONS 2916 The 2916 Indoor/Outdoor Keypad Surface Mount is a digital keyless entry system designed for access control applications. The keypad is integrated Features in a heavy cast vandal resistant housing, designed to be mounted on a...
  • Page 2 QuickStart Programming To enter Programming Mode, enter #9# plus the Master Code. The yellow indicator will blink slowly showing that the 2916 is in programming mode. Use the option codes to program each function. After the new data entry is complete for each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the programming has been accepted.
  • Page 3 OUTPUT #4 COM indicators or sounders. See fig. 5 for wiring examples using the solid state COMMON SOURCE outputs. BLACK OUTPUT #3 COM Fig. 5 Using Solid State Outputs 5/7/2012 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 ● (800) 325-9995...
  • Page 4 Programming the 2916 To Hold the Output and re-enter the command: Press: The 2916 has a “Toggle Mode” available for each relay and solid-state output. Setting Entry Code Length Default: 4 digits When an output is programmed for Toggle Mode, the output alternates from...
  • Page 5 Press: 1 2 # Output # Seconds Press: 2 3 # Output=Output to Activate (0-4) Seconds=Output time in seconds (0-60), 99=Toggle Mode 1=Main Relay; 2=Auxiliary Relay; 3=Output #3; 4=Output #4; 0=No Output 5/7/2012 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 ● (800) 325-9995...
  • Page 6 Sets the length of time an entry code will not function after it is used. Press: 5 1 # Minutes # Minutes=Time in minutes (1-4), 0=No Anti-passback 5/7/2012 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 ● (800) 325-9995...
  • Page 7 S-EA00080 3.000 5.750 1.375 SURFACE MOUNT 4X Mount at holes With supplied screws and hole expansion anchors MOUNTING TO SINGLE GANG RECESSED OUTLET BOX Mount at slots 5/7/2012 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 ● (800) 325-9995...
  • Page 8 2916 Keypad Installation Instructions S-EA00080 OPTIONAL SHROUD SURFACE MOUNT (WITH OPTIONAL SHROUD) 4" POST MOUNT (WITH SHROUD) 4" Mount at holes 5/7/2012 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 ● (800) 325-9995...

Table of Contents