CONTROL BOX
Description
Problem
ON/OFF switch is in the ON
position; power light is not
illuminated.
Power cord plugged in,
Motor does
not work.
Power indicator light
illuminated,
Handpiece will not turn on.
Motor works Unable to adjust speed.
HANDPIECE
Problem
Handpiece does not work, even
Faulty bearing, carbon brushes,
if the chuck is locked.
or control box.
Handpiece starts, then stops.
Faulty bearing.
Faulty bearing or collet chuck.
Loud noise and vibration while
in use.
Bent or broken bit.
Dealer:
M
ASHA'S NAILS SHOP
Tel. +1 (714) 204-5993 (WhatsApp ) |
mail @ 4nails . us
www.4nails.us
Possible Cause
Solution
Plug power cord into outlet.
Power cord not plugged in
Check and replace fuse
Blown Fuse
if necessary.
Overload protection
Unplug and re-connect
has been triggered.
power cord from outlet.
Check the handpiece
Bad connection from
connection at the control
control box to handpiece.
box.
Check the pedal
Bad connection from
connection at the control
control box to pedal.
box.
Handpiece connection
Contact your dealer.
cable damaged.
Replace carbon brushes,
Carbon brushes worn out.
or contact your dealer.
Faulty control box.
Contact your dealer.
Possible Cause
Solution
Contact your dealer.
Contact your dealer.
Contact your dealer.
Replace the bit.
Date of purchase:
Serial number:
4
USER MANUAL
NAIL
DRILL
Thank you for your purchase!
Proper maintenance and repairs will ensure years of trouble-free service.
Save this manual for future reference.
Saeshin is not responsible for accidents caused by not following the instructions.
Appearance and specifications are subject to change without further notice. Users are responsible for safe operation
and maintenance. By reporting the product, model and type of failure you can expect advice and fast service from your
dealer.
Specifications
Control Box
Size
Input Voltage
Power
(LxWxH)
110/220 V
5 ⅛ x 5 ½ x 3 ¼ in
65 W
(13х13,5х8,5 cm)
50/60 Hz
Component Overview
1
1 - Speed control knob
2 - Control box
3 - Forward/Reverse (FWD/REV) switch
4 - Voltage selector switch
(110/220V)
5 - ON/OFF switch
6 - Power cord
7 - Control switch (Hand/Foot)
8 - Pedal Connection
9 - Bit Holders
10 - Power indicator
11 - Foot pedal
12 - Handpiece Connection
13 - Handpiece
14 - Handpiece Holder
English
Handpiece
Rotation
Torque
Model
Length
Weight
Speed
0-40,000
6 in
105L
3 Ncm
(153 mm)
2.8 lb
RPM
(1.3 Kg)
0-35,000
5 in
120
3 Ncm
(129 mm)
RPM
6
8
3
4
5
7
14
9
10
12
210
Weight
7 oz
(190 g)
6 oz
(164 g)
11
13

Advertisement

loading

Summary of Contents for Strong 210

  • Page 1 Common Problems and Solutions USER MANUAL CONTROL BOX English Description Problem Possible Cause Solution ON/OFF switch is in the ON Plug power cord into outlet. Power cord not plugged in position; power light is not NAIL illuminated. Check and replace fuse Blown Fuse DRILL if necessary.
  • Page 2 * Do not use the device with a defective handpiece, damaged cord, or after dropping the unit WARRANTY or coming in direct contact with water. Saeshin warrants this unit for 1 year from the date of purchase. The warranty covers faults caused by the manufacturer, e.g.