Page 1
Description of AL101S series keypad Description of AL101S series lamp Chapter 2 - Size of AL101S series ECR / FWD / AFT Chapter 3 –Input & Output signal terminal of AL101S ECR / FWD / AFT Chapter 4 – Test flow chart of AL101S...
Page 2
Chapter 0 Factory Default 1. ECR 1.1 Dip Switch Switch Default Operation Mode Test Mode No DC blinking DC blinking Available Full Relay output Mode Half relay output Mode Operation Mode Download Mode 1.2 Resistor Termination ON/OFF switch: OFF...
Page 3
2. FWD / AFT 1.1 Dip Switch Switch Default Operation Mode Test Mode No DC blinking DC blinking Available Full Relay output Mode Half relay output Mode Operation Mode Download Mode 1.2 Resistor Termination ON/OFF switch: OFF CAUTION! ECR / FWD / AFT Relay output mode(Full / Half) run independently.
Page 8
1) SILENCE Key This key able to maintain to each lamp’s activation or deactivation After buzzer has activation, this key able to stop to buzzer sound CAUTION! If setting Dip Switch “3” setting done ON, relay output will be working full mode. Meanwhile if setting Dip switch “3”...
3) LAMP TEST Key This key able to all LAMP ON even each lamp has activation or deactivation This key check to LAMP itself working. If on pressing this key both of activation and deactivation lamp ON at once. Then if release this key the deactivation lamp will be OFF 4) DIMMER Key This key able to adjust to LAMP brightness Brightness has total 5 steps.
Page 10
Description of AL101S-ECR/FWD/AFT LAMP 1) FU FAIL LAMP Input signal “1” second later LAMP activate 2) PUMP HYDR. LOCK LAMP Input signal “1” second later LAMP activate 3) PHASE FAIL LAMP Input signal “2” second later LAMP activate 4) PUMP LOW OIL LEVEL LAMP Input signal “3”...
Page 11
AL101S Steering Gear Alarm System Chapter 2 ECR / FWD / AFT Case size...
Page 18
AL101S Steering Gear Alarm System Chapter 4 Test flow...
Page 19
4.1 Purpose : This alarm testing procedure is to check and confirm that the alarm system is working and meet the design requirement. 4.2 Testing Procedure 4.2.1 Connect the FWD, AFT & ECR panel as single line drawing. 4.2.2 Connect ECR panel to external alarm signals. The alarm signal can be turned off And on by a toggle switch.
Page 20
PUMP 1 RUN Step 1: Close PUMP 1 RUN switch Step 2: PUMP 1 RUN indicator light ON Step 3: Buzzer not on. Step 4: Open the PUMP 1 RUN switch Step 5: Indicator light off PUMP 1 STOP Step 1: Close PUMP 1 STOP switch Step 2: PUMP 1 STOP indicator light on Step 3: Buzzer not on.
Page 21
4.6 Testing for signal output to other equipment FWD & AFT alarm panel relay Signal output...