LG LPC483TAO Service Manual page 21

Floor standing type air conditioner
Table of Contents

Advertisement

12. Alarm mode display / only displayed while operating.
CO : The sensor for sensing room temperature is open or short.
C1 : The sensor for sensing piping temperature is open or short.
13. Energy Saving
If setting temperature of starting energy saving operation is under 22°C(71.6°F), first, setting temperature it
up to 22°C(71.6°F) and perform energy saving operation.
After energy saving operation starts, if adaptation time of the human body pass from the point which room
temperature and setting temperature meet together, increase setting temperature 1°C(1.8°F) more.
If it doesn't satisfy number
1°C(1.8°F).
After increasing setting temperature 1°C(1.8°F) more by number
temperature goes up to 25°C(77.0°F), maintain this temperature.
If setting temperature goes down to under 25°C(77.0°F), during the operation, do number
27 C(80.6 F)
26 C(78.8 F)
25˚C(77.0 F)
24 C(75.2 F)
23 C(73.4 F)
22 C(71.6 F)
21 C(69.8 F)
Setting energy
saving operation
14. AUTO RESTART
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
15. Function of changing set temperature when re-operation after stop.
Operation is set the following condition when re-operation with start/stop button.
1.Operation mode.
Cooling/soft dry mode
Heating mode
Heating mode
2. Setting the set temperature when cooling operation.
Room temperature > Set temperature: to be set to the previous set temperature.
Room temperature
a) Room temperature
b) 22°C(71.6°F)
c) 19°C(66.2°F)
d) Room temperature
even in 50 minutes from the start of energy saving operation, increase
28min.
50min.
Setting temp.
23 C(73.4 F)
Cooling mode
Set temperature
26°C(78.8°F): to be set to 24°C(75.2°F)
Room temperature
25°C(77.0°F): to be set to 21°C(69.8°F)
Room temperature
21°C(69.8°F): to be set to -1°C(1.8°F) less than room temperature.
18°C(64.4°F): to be set to 18°C(64.4°F)
35min.
47min.
50min.
50min.
Setting temp.
Setting temp.
24 C(75.2 F)
25 C(77.0 F)
–21–
,
, perform number
,
maintains setting temp.
25 C(77.0 F)
again, if setting
,
,
again.