Mitsubishi Electric 9700 Series Owner Technical Manual page 60

Uninterruptible power supply system
Hide thumbs Also See for 9700 Series:
Table of Contents

Advertisement

MITSUBISHI
ELECTRIC
UF254
UF255
UF256
UF257
UF301
UF302
UF303
UF304
UF305
UF306
UF309
UF351
UF352
UF355
(Note10)
UF356
UF357
UF358
UF359
UF360
UF362
UF401
UF402
UF451
UA801
UA802
UA803
UA804
(Note10)
UA805
(Note10)
UA806
UA807
UA808
UA809
UA810
UA811
Get user manuals:
See SafeManuals.com
OWNERS / TECHNICAL MANUAL
88C ABNORMAL
Fan power source abnormality during operation
52C ABNORMAL
52C turned OFF during inverter power supply
OUTPUT VOLTAGE
Inverter output voltage fell out of +/- 5%
ABNORMAL
52C ABNORMAL
52C not turned OFF when manual transfer
UPS CONTROL CIRCUIT
Control microcomputer abnormality
ERROR
UPS CONTROL CIRCUIT
Control microcomputer abnormality
ERROR
UPS CONTROL CIRCUIT
Control microcomputer abnormality
ERROR
UPS CONTROL CIRCUIT
Control microcomputer abnormality
ERROR
UPS CONTROL CIRCUIT
Control circuit abnormality
ERROR
UPS CONTROL CIRCUIT
Control power source circuit abnormality
ERROR
INVERTER VOLTAGE
Inverter output voltage abnormality before
ABNORMAL
inverter power supply
CONTROL FUSE BLOWN Battery circuit's fuse burnt
SUPPLY OF CONTROL
Control circuit abnormality
CIRCUIT ABNORMAL
UPS CONTROL CIRCUIT
Control circuit abnormality
ERROR
UPS CONTROL CIRCUIT
Control circuit abnormality
ERROR
"INVERTER START "
"INVERTER START" button is abnormal (Local)
BUTTON ABNORMAL
"INVERTER STOP "
"INVERTER STOP" button is abnormal (Local)
BUTTON ABNORMAL
"INVERTER SUPPLY"
"INVERTER SUPPLY" button is abnormal
BUTTON ABNORMAL
"BYPASS SUPPLY"
"BYPASS SUPPLY" button is abnormal
BUTTON ABNORMAL
UPS CONTROL CIRCUIT
52S control circuit abnormality (Note 8)
ERROR
52S not turned ON, or 52S turned ON without
52S ABNORMAL
any command
52S not turned OFF, or 52S turned OFF without
52S ABNORMAL
any command
52S not turned ON, or 52S turned ON without
52S ABNORMAL
any command when manual transfer
AC INPUT VOLTAGE OUT
AC input voltage fell out of +/- 18% range
OF RANGE
AC INPUT FREQUENCY
Ac input frequency fell out of converter
OUT OF RANGE
synchronization follow-up range
AC INPUT PHASE
Phase rotation is inverted when input voltage is
ROTATION ERROR
normal
BATTERY ABNORMAL
Battery abnormal (External input)
AMBIENT TEMPERATURE
Temp. abnormality in room where installed
ABNORMAL
INVERTER OVERLOAD >
Overload exceeded 105% (Note 9)
100%
INVERTER OVERLOAD >
Overload exceeded 110% (Note 9)
110%
INVERTER OVERLOAD >
Overload exceeded 125% (Note 9)
125%
INVERTER OVERLOAD >
Overload exceeded 150% (Note 9)
150%
OVERLOAD
Momentary over-current during Inverter power.
BYPASS VOLTAGE OUT
Bypass voltage fell out of +/- 15% range at
OF RANGE
manual transfer
9700 SERIES UPS
MITSUBISHI ELECTRIC 9700 SERIES UPS
Page Number:
6-3
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[2]
Major
Lit up
1
[2]
Major
Lit up
1
[2]
Major
Lit up
1
[2]
Major
Lit up
1
[2]
Major
Lit up
1
[2]
Major
Lit up
1
[2]
Major
Lit up
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[1]
Minor
Flicker
1
[2]
Major
Lit up
1
[2]
Major
Lit up
1
[1]
Minor
Flicker
3
[1]
Note 5
3
[1]
Note 5
3
[1]
Note 5
1
[1]
Note 5
11
[1]
4
[1]
Over
Flicker
4
[1]
Over
Flicker
4
[1]
Over
Flicker
4
[1]
Over
Flicker
4
[1]
Over
Flicker
5
[1]
Note 5
197
128
109
98
19
28
29
31
21
16
83
115
111
130
123
124
125
126
127
195
84
85
99
239
161
236
238
237
216
217
218
219
220
240

Advertisement

Table of Contents
loading

Table of Contents