Beko DRYPOINT RA 200/AC NA Operating Manual page 2

Refrigerating air dryer
Table of Contents

Advertisement

Dear Customer,
thank you for choosing our product. In order to get the best performances out of this product, please read this manual
carefully.
To avoid incorrect operation of the equipment and possible physical risk to the operator, please read and strictly follow
the instructions contained in this manual.
Note, these instructions are in addition to the safety rules that apply in the country where the dryer is installed. Before
packing for shipment each DRYPOINT RA NA series refrigerated air dryer undergoes a rigorous test to ensure the
absence of any manufacturing faults and to demonstrate that the device can perform all the functions for which it has
been designed.
Once the dryer has been properly installed according to the instructions in this manual, it will be ready for use without
any further adjustment. The operation is fully automatic, and the maintenance is limited to few controls and some
cleaning operations, as detailed in the following chapters.
This manual must be maintained available in any moment for future references and it has to be intended as inherent
part of the relevant dryer.
Due to the continuous technical evolution, we reserve the right to introduce any necessary change without giving
previous notice.
Should you experience any trouble, or for further information, please do not hesitate to contact us.
The data nameplate is located on
the back of the dryer and shows
all
the
primary
data
machine. Upon installation, fill in
the table on the previous page
with all the data shown on the
data nameplate. This data should
always be referred to when calling
the manufacturer or distributor.
The removal or alteration of the
data nameplate will void the
warranty rights.
2
DATA NAMEPLATE
of
the
Working pressure PS min/max
Inlet temperature TS max
Refrig. Design Pres. HP/LP
Electric Nominal Power
Model
Product key
Serial n° .
Nominal Flow Rate
Ambient Temp.
Refrigerant
Power supply
Fuse Max.
DRYPOINT RA
Product key:
Produktschlüssel:
Serial n° / year of building:
Serienr. / Baujahr:
Nominal flow rate (ISO1217):
Nemmvolumenstrom (ISO1217):
Working pressure PS min/max:
Betriebsüberdruck PS min/max:
Inlet temperature TS max:
Eintrittstemperatur TS max:
Ambient Temperature:
Umgebungstemperatur:
Refrigerant:
Kältemittel:
Refrig. Design Pres. HP/LP:
Kältem. Auslegungsdruck HD/ND:
Power supply:
Elektrischer Anschluß:
Electric Nominal Power:
Elektrische Leistung:
Fuse protection max:
Absicherung max:
BEKO TECHNOLOGIES GMBH
Im Taubental 7, 41468 Neuss
Germany
http:// www.beko.de
DRYPOINT RA 200 – 2500 NA
scfm
psig
° F
° F
type/oz
psig
V/ph/Hz
W/A
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents