1.
Introductory Remarks ......................................................................................................... 2
2.
Application........................................................................................................................... 2
3.
Reservations of Producer ................................................................................................... 3
4.
Technical Data ..................................................................................................................... 3
5.
Structure and Function ....................................................................................................... 5
6.
Assembly and Start-up ....................................................................................................... 6
7.
Operational Use ................................................................................................................... 7
8.
Troubleshooting Guide ....................................................................................................... 7
9.
Maintenance ........................................................................................................................ 7
10.
Occupational Health and Safety ......................................................................................... 8
11.
Transport and Storage ........................................................................................................ 8
12.
Terms of warranty ............................................................................................................... 8
13.
Sample of the Declaration of Conformity ........................................................................ 12
814R21 ERGO-L/Z-2/Ex
814R22 ERGO-L/Z-3/Ex
814R23 ERGO-L/Z-4/Ex
814R24 ERGO-L/Z-2-R/Ex 10.01.2019/EN
814R25 ERGO-L/Z-3-R/Ex 10.01.2019/EN
814R26 ERGO-L/Z-4-R/Ex 10.01.2019/EN
10.01.2019
1
II 2 G/D c
10.01.2019/EN
10.01.2019/EN
10.01.2019/EN
explosion-proof extraction arms ERGO-L/Z-{2;3;4}/Ex
/

Advertisement

Table of Contents
loading

Summary of Contents for Klimawent ERGO-L/Z-2/Ex

  • Page 1: Table Of Contents

    Troubleshooting Guide ....................... 7 Maintenance ........................7 Occupational Health and Safety ..................8 Transport and Storage ......................8 Terms of warranty ....................... 8 Sample of the Declaration of Conformity ................ 12 814R21 ERGO-L/Z-2/Ex 10.01.2019/EN 814R22 ERGO-L/Z-3/Ex 10.01.2019/EN 814R23 ERGO-L/Z-4/Ex 10.01.2019/EN 814R24 ERGO-L/Z-2-R/Ex 10.01.2019/EN...
  • Page 2: Ergo -L/Z{2;3;4}/ Ex Ergo -L/Z{2;3;4} R / Ex

    1. Introductory Remarks The purpose of the present Use and Maintenance Manual is to supply User with directions wi- thin the range of application, installation, start-up and the use of the ERGO/Ex explosion-proof extraction arms . Installing, start up and operational use are exclusively admissible after getting acquaint- ted with the contents of the Use and Maintenance Manual.
  • Page 3: Reservations Of Producer

    Extraction arms are manufactured in three sizes: of maximum range 2m, 3m, 4m Dimensions of the ERGO/Ex extraction arm: Dimensions Weight Type [kg] [mm] [mm] [mm] [mm] [mm] ERGO-L/Z-2/Ex 2280 22,5 ERGO-L/Z-3/Ex 3100 1527 25,5 ERGO-L/Z-4/Ex 3710 1907 1050 28,0 Fig.
  • Page 4 3643 1907 1050 25,0 Fig. No.2 – ERGO-L/Z … -R/Ex – Dimensions Type A [mm] B [mm] C [mm] D [mm] Type A [mm] B [mm] C [mm] D [mm] ERGO-L/Z-2/Ex ERGO-L/Z-2-R/Ex 1440 1650 2280 2110 1487 2213 ERGO-L/Z-3/Ex ERGO-L/Z-3-R/Ex...
  • Page 5: Structure And Function

    Fig. No.3 – ERGO-L/Z-{2;3;4}/Ex, ERGO-L/Z-{2;3;4}-R/Ex – Flow charts (hanging and standing version) 5. Structure and Function Extraction arms type ERGO-L/Z-(2,3,4)/Ex and ERGO-L/Z-(2,3,4)-R/Ex consist of subsequent assemblies – as specified in the drawings (see pages 9 and 10). ● full-rotation swivel (stainless steel), ●...
  • Page 6: Assembly And Start-Up

    6 bolts M6x40 – stainless steel. The construction of the WB-ERGO-L/G wall brackets (manufactu- red by KLIMAWENT S.A.) additionally provides installing the ex- traction fans. Wall brackets can be mounted on the wall (or on another construc- tion) through stainless steel bolts M10.
  • Page 7: Operational Use

    − In case of replacement necessity of any element in the extraction arm (i.e. gas spring, hose, pipe segments, hood, grounding cables), use original parts only, delivered by KLIMAWENT S.A. − Any repairs ought to be executed in rooms not being in explosion hazard zone.
  • Page 8: Occupational Health And Safety

    10. Occupational Health and Safety − In application where the extraction arms are used in dust-laden atmospheres, syste- matically check the cleanness of the extraction arms, remove the dust deposited in- side and on the device – to avoid self-ignition of the residues dust layers. Execute the cleaning in a zone free from explosion hazard.
  • Page 9 explosion-proof extraction arms ERGO-L/Z-{2;3;4}/Ex 10.01.2019...
  • Page 10 explosion-proof extraction arms ERGO-L/Z-{2;3;4}/Ex 10.01.2019...
  • Page 11 Grounding cables of the extraction arms ERGO-L/Z-(2;3;4)/Ex oraz ERGO-L/Z-(2;3;4)-R/Ex explosion-proof extraction arms ERGO-L/Z-{2;3;4}/Ex 10.01.2019...
  • Page 12: Sample Of The Declaration Of Conformity

    Declaration of conformity EC No. …………….. Manufacturer (eventually the authorized representative / importer): name: KLIMAWENT S.A. address: 81-571 Gdynia, Chwaszczyńska 194 A person, authorized for issuing the technical documentation: Teodor Świrbutowicz, KLIMAWENT S.A. hereby declares that the appliance: name: Explosion-proof extraction arms type/model: ERGO-L/Z-[2,3,4]/Ex, ERGO-L/Z-[2;3;4;]-R/Ex...