Model W138A02/ ICP® Pressure Sensor Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
Assistance is needed to safely operate equipment PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
Page 3
CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
Page 5
Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
Page 6
OPERATION MANUAL FOR Series 138 Series 138 Standard Length, with Lead Wire Hole for Attaching Weights Series 138 Short Length, One-Piece Molded Closed-End Tube INTRODUCTION Series 138 is used by the military for underwater PCB Series 138 sensors are voltage mode tourmaline explosive testing, commercial use in gasoline tanks sensors designed for operation underwater or in and transformer shock wave applications.
Page 7
OPERATION MANUAL FOR Series 138 PCB Model 070A03 adaptor can be used to adapt the Some models of the Series 138 feature a tygon tube 10-32 micro jack on the 138 to a BNC jack. A heavier closed at one end with conical-shaped delrin plug. The coaxial cable (eg.
OPERATION MANUAL FOR Series 138 If indicator is in green section of indicator panel, the The steel wire can have a weight attached to it to IC amplifier is producing proper bias (+8 to 14 VDC), submerge the entire assembly. Tape or attach the cable connections are normal and the system is ready coaxial cable loosely to the steel wire at ~one foot to operate.
4.) Do not apply voltage to sensor without current- limiting diodes or other current protection. 5.) Do not apply more than 20 mA of current to the sensor. ®ICP is a registered trademark of PCB Piezotronics, Inc. Drawing Number: 21102 Revision: B...
Page 10
3425 Walden Avenue, Depew, NY 14043 All specifications are at room temperature unless otherwise specified. In the interest of constant product improvement, we reserve the right to change specifications without notice. ® is a registered trademark of PCB Piezotronics, Inc.