Amersham Pharmacia Biotech P-910 Instructions Manual

Advertisement

Quick Links

1 Introduction

Pump P-910 is a single channel peristaltic
laboratory pump for use as a sample pump to
fill sample loops in an ÄKTA
chromatography system. Pumping action is
provided by a roller cage driven by a stepper
motor controlled from a PC running
UNICORN
control system, version 2.10 or
higher.
Features:
Flow rates up to 5 ml/min.
Accurate and reproducible flow rate.
Safety
WARNING! When using hazardous
chemicals, all suitable protective measures,
such as protective glasses, must be taken.

2 Installation

CAUTION! Before connecting Pump P–910
ensure the power is switched OFF at the pump
or for the complete system.
Unpacking
Unpack the instrument and check the items
against the packing list. Inspect the items for
obvious damage which may have occurred
during transportation.
Installing the pump
At delivery, the pump is ready to use, with
only the tubing to be installed.
1
Mount the pump vertically, in the way it
is shown in the user documentation of
your ÄKTAdesign chromatography sys-
tem.
56-3000-47
Edition AD
design
Pump P-910
2
Connect the pump with
two UniNet cables as a
part of the UnitNet 2
chain.
Assembling pump tubing
1
Cut the pump tubing squarely to length of
140 mm.
2
Insert one connector
in each end of the
tubing.
3
The distance between the two connectors
must be 140 mm. This ensures firm
positioning of the tubing.
140 mm
Instructions
UniNet 2 chain

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P-910 and is the answer not in the manual?

Questions and answers

Summary of Contents for Amersham Pharmacia Biotech P-910

  • Page 1 Pump P-910 Instructions 1 Introduction Pump P-910 is a single channel peristaltic laboratory pump for use as a sample pump to fill sample loops in an ÄKTA design ™ chromatography system. Pumping action is provided by a roller cage driven by a stepper...
  • Page 2 Inserting the tubing 3 Operation 1 Open the door. Pump P-910 is controlled from a PC running 2 Push back the UNICORN version 2.10 or higher. It cannot pressure plate. be used as a stand-alone instrument. Control of the pump can be achieved automatically 3 Insert the tubing.
  • Page 3 4 Maintenance 8 Measure the volume collected in CAUTION! Only spare parts approved or the measuring cylinder. Enter this value in supplied by Amersham Pharmacia Biotech . Click on then Reference field Set ref value may be used for maintaining and servicing...
  • Page 4 Waves of compression pass along the tubing without dragging the tubing in the direction of movement of the roller cage. Pump P-910 Instructions 56-3000-47 Edition AD...
  • Page 5 Item Quantity Code no. Operating data per pack Flow rate range 0 - 5 ml/min Pump P-910, including Pressure range 0 - 0.1 MPa (1 bar, 14 psi) pump tubing and one Flow rate accuracy UniNet cable 18-1113-86 <±10% of setting or Pump tubing, i.d.
  • Page 6 Pump P-910 Instructions 56-3000-47 Edition AD...
  • Page 7 Pump P-910 Instructions 56-3000-47 Edition AD...
  • Page 8 All goods and services are sold subject to the terms understood and all stated conditions are met. and conditions of sale of the company within the Amersham Pharmacia Biotech group which supplies Note them. A copy of these terms and conditions of sale is The Note sign is used to indicate information available on request.

Table of Contents