FoxInsights FoxPressure User Manual

FoxInsights FoxPressure User Manual

Level meter
Hide thumbs Also See for FoxPressure:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Benutzerhandbuch | User manual | Manuel d'utilisation
made by
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FoxPressure and is the answer not in the manual?

Questions and answers

Summary of Contents for FoxInsights FoxPressure

  • Page 1 Benutzerhandbuch | User manual | Manuel d’utilisation made by...
  • Page 2: Table Of Contents

    Inhalt Willkommen Überblick Funktionsweise Sicherheitshinweise Einrichtung per App Hinweise zum Einbau Technische Daten...
  • Page 3: Willkommen

    Geräts Zeit, um dieses Benutzerhandbuch gewissenhaft zu lesen. Nur bei sorgfältiger Montage und richtiger Bedienung können die Leistungs- fähigkeit des FoxPressure optimal genutzt und die Betriebssicherheit gewährleistet werden. Bitte stellen Sie daher sicher, dass alle Personen, die das Gerät montieren und bedienen, dieses Benutzerhandbuch sowie die Montageanweisungen in der FoxMobile App (siehe Seite 7) gelesen und verstanden haben.
  • Page 4: Überblick

    Überblick Deckel mit Schrauben Silikonband zur zum Öffnen bei Batteriewechsel Fixierung des FoxPressure in der Klebehalterung Einschaltknopf aktiviert den FoxPressure durch einmaliges Drücken 2 Status LEDs zeigen Geräte- und Klebehalterung Funkstatus und leuchten nur bei manueller Betätigung Klebefolie zur Positionierung...
  • Page 5: Funktionsweise

    Funktionsweise Der FoxPressure dient der einfachen Messung des Füllstands in Tanks. Diese erfolgt mittels Erfassung des hydrostatischen Drucks der Füllstandssäule. Die Berechnung des Füllstands erfolgt mit Hilfe des gemessenen Drucks und der Dichte. Der FoxPressure ist kein geeichtes Messgerät. Die Genauigkeit der Inhaltsangabe beruht dabei auf Übereinstimmung der angegebenen Daten in der Konfiguration der...
  • Page 6: Sicherheitshinweise

    Sicherheitshinweise Der FoxPressure wird mit Batterien betrieben. Bitte verwenden Sie nur hochwertige, auf lange Laufzeit ausgelegte Batterien. Für Schäden am Gerät, die durch ausgetauschte Batterien entstanden sind, wird keine Haftung übernommen. Der FoxPressure darf nicht: in Tanks mit beweglichen Teilen verwendet werden im Tank bleiben, wenn eine Peilstab-Messung durchgeführt wird,...
  • Page 7: Einrichtung Per App

    Einrichtung per App Der FoxPressure wird ganz unkompliziert über Ihr Smartphone eingerichtet. Hierzu benötigen Sie die kostenlose FoxMobile App aus dem iOS App Store (für iPhones) oder dem Google PlayStore (für Android Geräte). Starten Sie den Download über www.foxmobile.app oder scannen Sie einfach den untenstehenden QR Code mit Ihrer Smartphone Kamera.
  • Page 8: Hinweise Zum Einbau

    Passen Sie zunächst die Kabellänge auf Ihren Tank an. Generell empfehlen wir die Länge so einzustellen, dass sie der Tankhöhe + Offset + 5 cm entspricht. Senken Sie anschließend die Drucksonde des FoxPressure langsam(!) in den Tank ab, bis sie Kontakt mit dem Tankboden hat. Ein ruckartiges Fallenlassen sollte dabei unbedingt vermieden werden, da der FoxPressure beschädigt...
  • Page 9: Technische Daten

    2G, Cat-M FoxPressure, Klebeadapter, Silikonband, Tankadapter, 1" Lieferumfang Adapter für Außengewinde, 3 Batterien (Typ AA) eingelegt, Reinigungstuch, Benutzerhandbuch *durch schlechte Signalstärke kann sich die Batterielaufzeit reduzieren Der FoxPressure ist bei der FoxInsights GmbH unter der WEEE Nummer DE 87528297 registriert.
  • Page 10 Table of contents Welcome Overview Functionality Safety instructions App setup Notes on installation Technical data...
  • Page 11: Welcome

    Thank you for choosing our innovative level meter. Please take the time to read this user manual carefully before setting up and using the device. For optimal performance and guaranteed operational safety, the FoxPressure must be installed carefully and operated correctly.
  • Page 12: Overview

    Adhesive mount status with only light up when operated manually Adhesive film for positioning the FoxPressure on the plastic tank Installation ring Pressure probe 3 thread sizes: measures in the range 1 ˝ , 1 ½ ˝ und 2 ˝ (inch) 0 – 300 mbar, 0 – 3.5 m heating oil/...
  • Page 13: Functionality

    Functionality The FoxPressure is used for simple measurement of the tank levels. This is done by detecting the hydrostatic pressure of the level column. The level is then calculated using the measured pressure and density. The FoxPressure is not a calibrated measuring device. The accuracy of...
  • Page 14: Safety Instructions

    Safety instructions The FoxPressure is battery-powered. Please only use high quality batteries designed for a long service life. No liability is accepted for damage to the device arising from replaced batteries. The FoxPressure must not: be used in tanks with moving parts remain in the tank when taking a dipstick measurement, provided it is mounted on the dipstick tube.
  • Page 15: App Setup

    App setup The FoxPressure is easily set up using your smartphone. To do this, download the free FoxMobile app from the iOS App Store (for iPhones) or the Google PlayStore (for Android devices). Start the download by visiting www.foxmobile.app or simply scan the QR code below with your smartphone camera.
  • Page 16: Notes On Installation

    + offset + 5 cm. Then lower the pressure probe of the FoxPressure slowly(!) into the tank until it rests on the bottom of the tank. Dropping the probe in a sudden manner should be avoided, as the FoxPressure could be damaged.
  • Page 17: Technical Data

    FoxPressure, adapter with adhesive surface, silicone band, scope of delivery tank adapter, 1" adapter for external thread, 3 batteries (type AA) inserted, cleaning cloth, user manual *poor signal strength may reduce battery-lifetime The FoxPressure is registered with FoxInsights GmbH under the WEEE number 87528297.
  • Page 18 Table des matières Bienvenue Aperçu Comment ça marche Instructions de sécurité Configuration via l’application Precisions concernant l’assemblage Donnees techniques...
  • Page 19: Bienvenue

    Ce n’est qu’avec une installation soignée et une utilisation correcte que les performances du FoxPressure peuvent être utilisées de manière optimale et que la fiabilité opérationnelle peut être assurée. Par conséquent, veuillez vous assurer que toutes les personnes qui assem- blent et utilisent l’appareil ont lu et compris ce manuel d’utilisation ainsi que...
  • Page 20: Aperçu

    FoxPressure dans le support adhésif Bouton de mise sous tension active le FoxPressure en appuyant une fois dessus 2 voyants lumineux LED indiquent l’état de Support adhésif l’appareil et la connexion, et ne s’allument que lorsque l’on appuie sur le...
  • Page 21: Comment Ça Marche

    Le niveau est calculé à partir de la pression et de la densité mesurée. Le FoxPressure n’est pas un appareil de mesure calibré par la loi. La précision du contenu est basée sur la cohérence des données spécifiées lors de la configuration sur l’application et les caractéristiques...
  • Page 22: Instructions De Sécurité

    Consignes de sécurité Le FoxPressure fonctionne avec des piles. Merci d’utiliser seulement des piles de bonne qualité pour un usage long-terme. Aucune responsabilité ne sera engagée pour tout dommage causé par des piles de substitution. Le FoxPressure ne doit pas : être utilisé...
  • Page 23: Configuration Via L'application

    Configuration via l’application Le FoxPressure se configure facilement via votre smartphone. Pour ce faire, vous avez besoin de l’application gratuite FoxMobile disponible sur l’App Store iOS (pour les iPhones) ou le PlayStore Google (pour les appareils Android). Commencez le téléchargement via www.foxmobile.app ou scannez simplement le code QR ci-dessous avec l’appareil photo de votre smartphone.
  • Page 24: Precisions Concernant L'assemblage

    à ce qu’elle corresponde à la hauteur du réservoir + offset + 5 cm. Ensuite, faites descendre lentement (!) la sonde de pression du FoxPressure dans le réservoir jusqu’à ce qu’elle soit en contact avec le fond du réservoir. Il faut absolument éviter de la laisser tomber brusquement, car le FoxPressure...
  • Page 25: Donnees Techniques

    3 piles (de type AA) déjà installées, chiffon de nettoyage, manuel d’utilisation *une mauvaise qualité du signal peut réduire la durée de vie des piles Le FoxPressure est enregistré par l’entreprise FoxInsights GmbH sous le numéro DEEE 87528297.
  • Page 26 Platz für Notizen Space for Notes Espace pour les notes...