Reno A&E S-1212 Operating Instructions

Two channel loop detector

Advertisement

I

Factory Default Settings

Function
Loop Frequency (8 settings)
Sensitivity Level (OFF, 1 to 9, CALL)
Presence / Pulse Mode
Call Delay Time (0 to 255 seconds)
Call Extension Time (0 to 25.5 seconds)
Max Presence Time (OFF, 1 to 999 seconds)
End-of-Green (EOG)
Option 1 - Display Loop Inductance (L) *
Option 2 - Display % Loop Inductance Change (-∆L/L) *
Option 3 - Call Extension Control
Option 4 - Noise Filter Disable *
Option 5 - Phase Green Loop Compensation
Option 6.0 - Display Vehicle Count
Option 6.1 - Reset Vehicle Count
Option 7 - Number of Loops for Vehicle Counting
Option 9 - Third Car Passage *
Option 10 - Directional Logic *
Option 11 - Audible Detect Signal **
Option 12 - Detector Disconnect **
Detect ID
NOTES: * These settings affect both channels.
** These settings affect each channel independently.
II
Viewing and Programming Detector Functions
i
Entering and Exiting Program Mode
Enter the Program mode by momentarily pressing the FUNC pushbutton. Use the FUNC pushbutton to step through the
functions described below.
Press the CHAN pushbutton to select the channel to view or make changes to. The channel that is in Program mode is
indicated by a flashing numbered-loop symbol at the bottom of the Liquid Crystal Display (LCD).
To change a function's setting or to toggle a function ON or OFF, press the  (UP) or  (DOWN) pushbutton.
To exit the Program mode and return to the Normal display mode, press and hold the CHAN pushbutton continuously for one
second.
Loop Frequency
Loop Frequency can be adjusted from 1 to 8. Press the  (UP) or  (DOWN) pushbutton to change the programmed Loop
Frequency. The filled segment on the bargraph indicates the setting. The left-most segment represents setting 1 and the right-most
segment represents setting 8. The LCD displays the actual operating frequency of the loop circuit. A separation of at least 5 KHz for
adjacent loops, not connected to the same detector, is recommended. The factory default setting is Loop Frequency 3 for Channel 1
and Loop Frequency 7 for Channel 2. NOTE: Changing the Loop Frequency setting will reset the detector channel. The Loop
Frequency setting should not be changed while the detection zone is occupied.
Model S-1212 Operating Instructions
MODEL S-1212
Firmware Version 35.02
TWO CHANNEL LOOP DETECTOR
OPERATING INSTRUCTIONS
3510 E. Atlanta Ave.
Phoenix, AZ 85040 USA
Telephone: (480) 968-6407
Website: www.editraffic.com
E-mail: contact@editraffic.com
Channel 1 Channel 2
3
7
6
6
Presence
Presence
0
0
0.0
0.0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
04
04
OFF
OFF
OFF
OFF
OFF
OFF
Off
OFF
000
000
1
Fax: (602) 437-1996
P/N 889-1910-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S-1212 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Reno A&E S-1212

  • Page 1 The factory default setting is Loop Frequency 3 for Channel 1 and Loop Frequency 7 for Channel 2. NOTE: Changing the Loop Frequency setting will reset the detector channel. The Loop Frequency setting should not be changed while the detection zone is occupied. Model S-1212 Operating Instructions P/N 889-1910-00...
  • Page 2 It is recommended that this option only be turned ON when the detector is used for speed and/or occupancy measurement applications. The factory default setting of Option 4 is OFF for both channels. NOTE: Turning this option ON for either channel turns it ON for both channels. Model S-1212 Operating Instructions P/N 889-1910-00...
  • Page 3 This feature is used to assign a unique identification value to the detector for communication purposes. Detector ID settings can range from 000 to 253. Pressing either the  (UP) or  (DOWN) pushbutton will increment or decrement the ID setting by one digit. NOTE: When first initialized, the detector ID setting is 000. Model S-1212 Operating Instructions P/N 889-1910-00...
  • Page 4 The best method to reduce adjacent loop detection is to reduce the Sensitivity Level by the number of segments that are flickering, however this will also eliminate the ability to reliably detect small motorcycles. Model S-1212 Operating Instructions P/N 889-1910-00...