Download Print this page

SolarMAN WP-2S User Manual

Hide thumbs Also See for WP-2S:

Advertisement

Quick Links

User Guide for Weather Station v1.0
User Guide for Weather Station
Model:WP-2S

Advertisement

loading
Need help?

Need help?

Do you have a question about the WP-2S and is the answer not in the manual?

Questions and answers

Summary of Contents for SolarMAN WP-2S

  • Page 1 User Guide for Weather Station v1.0 User Guide for Weather Station Model:WP-2S...
  • Page 2: Installation Preparation

    User Guide for Weather Station v1.0 1. Installation Preparation 1.1 Checklist Bracket Bakelite Lead Wire Lightning Arrester M12x110mm Expansion Screw x3 Horizontal radiation fixed cross arm Irradiance Sensor x2 Integrated Sensor Fixing Set for Integrated Sensor Junction Box+Temperature Sensor Fixing Set for Junctio n Box x2...
  • Page 3: Bracket Installation

    User Guide for Weather Station v1.0 Please confirm the checklist before installation. If any damage, loss or inconformity found in the devices or parts, please contact the manufacturer immediately. Please do not disassemble the connected wiring. 1.2 Tools Cross Screwdriver djustable Spanner incer Pliers Wire Stripper...
  • Page 4 User Guide for Weather Station v1.0 Ground 1. Please confirm that there is no shelter 5 meters around bracket and sensors installation site. 2. For safety reasons, please cover the wire with PVC pipe. If the wire must go underground, please take waterproof measures and install an air switch. 3.
  • Page 5 User Guide for Weather Station v1.0 2.2 Lightning Arrester Installation Please assemble lightning arrester, bakelite, lead wire as follows. (Remove 4 screws on the top, insert a bakelite and tighten the screws.) Lightning Arrester & Lead Wire Lightning Arrester & Bakelite Warning The lightning rod is required, if the installation site is in the wild.
  • Page 6 User Guide for Weather Station v1.0 2.3 Irradiance Sensor Installation 1. Connect irradiance sensor with integrated sensor as follows. 2.Unscrew the protective cover of irradiance Sensor. In the same way, the horizontal radiation meter is fixed on the bracket by fixing the horizontal arm with the horizontal radiation sensor.
  • Page 7 User Guide for Weather Station v1.0 2.4 Integrated Sensor Installation 1. Please confirm that N sign should point to the north. 2. If you do not want to install a lightning rod, please install the integrated sensor on the bracket. If you want to install a lightning rod, please install the integrated sensor on the cross arm.
  • Page 8: Junction Box Installation

    User Guide for Weather Station v1.0 2.5 Junction Box Installation Please fix the junction box on the bracket and tighten the screws. 3. Connection 3.1 Integrated Sensor Connect a temperature sensor with an integrated sensor via this wiring. Warning 1. Please power off the device during the connection. 3.2 Connection between Logger and Weather Station...
  • Page 9 User Guide for Weather Station v1.0 1. Connect 485A (Green) to logger interface A Connect 485B (Blue) to logger interface B 2. Connect "DC 12V" (Red) to logger "+" interface Connect "GNG" (Black) to logger power input interface 3. Check if the wiring is correct...
  • Page 10 User Guide for Weather Station v1.0 Connection Diagram 4. Connect L-line and N-line according to L/N sign. Power on the device and all indicator lights keep on. Waring...
  • Page 11 2. Please make sure the DC connection is correct. 5. Tighten waterproof cap. USER MANUAL for SOLARMAN APP 1. Download app iPhone: Search “SOLARMAN Smart”/ “SOLARMAN BUSINESS” in Apple Store. Android: Search “SOLARMAN Smart”/ “SOLARMAN BUSINESS” in Google Play. You can also login via WEB as below:...
  • Page 12 User Guide for Weather Station v1.0 pro.solarmanpv.com home.solarmanpv.com 2. Registration on SOLARMAN SMART Go to SOLARMAN SMART and register. Click “Register”and create your account here. 3. Create a Plant Click "Add Now" to create your plant. Please fill in plant basic info and other info...
  • Page 13 User Guide for Weather Station v1.0 4. Add a Device Method 1: Enter logger SN manually. Method 2: Click the icon in the right and scan to enter logger SN You can find logger SN in the external packaging or on the logger body.
  • Page 14 User Guide for Weather Station v1.0 5.Network Configuration [This step is required for logger (WiFi). For logger (GPRS)/logger (4G), users can skip this step.] After the logger is added, please configure the network to ensure normal operation. Go to "Plant Details"-"Device List", find the target SN and click "Networking". Step 1:Confirm Wi-Fi Info Please make sure your phone has connected to the right WiFi network.
  • Page 15 If the password is required, you can find the password on the logger body. Go back to SOLARMAN Smart APP, after connecting to AP network. Step 3:Auto Configuration Please wait for a while to complete the configuration. Then system will switch to the...
  • Page 16 User Guide for Weather Station v1.0 following page. Click "Done" to check plant data. (Usually, the data will be updated in 10 mins) If configuration failure occurs, please check the following reason and try it again. (1) Make sure WLAN is ON. (2)...
  • Page 17: Warranty Card

    User Guide for Weather Station v1.0 WARRANTY CARD Dear Customers, Thank you very much for using our products. In order to provide you with better service, please fill in the warranty card and reserve it carefully. User Name Customer Name Purchase Customer Phone Date...
  • Page 18 User Guide for Weather Station v1.0 小型自动气象站 WP-2S 安装指南...
  • Page 19 User Guide for Weather Station v1.0 1. 安装须知 1.1 设备清单 M12x110mm 膨胀螺丝 x3 立杆支架 电木 引雷线 避雷针 总辐照传感器 x2 一体式传感器 一体式传感器固定套件 接线箱+贴片温度传感器 接线箱固定套件 x2 水平面辐射固定横臂 在安装之前,请仔细核对包装清单,如发现有设备或者任何零件存在损坏、丢失或者型号不 符等问题,请立即联系厂家。...
  • Page 20 User Guide for Weather Station v1.0 提示 为避免设备损坏,请打开包装过程中避免碰撞。已连接好的接线请勿拆卸。 1.2 安装工具 请预先准备好下列安装工具以便现场安装时使用。 十字螺丝刀 活动扳手 老虎钳 剥线钳 冲击钻...
  • Page 21 User Guide for Weather Station v1.0 2. 气象站安装 2.1 立杆支架安装 4. 安装地点要求:安装时,支架及传感器5米范围内不能有遮挡光照的植被及建筑物,10 米范围内不能有影响风向风速的地貌、植被及建筑物,地面需平坦开阔,如果是土质地面需 做好水泥基础(至少直径为80cm、厚度25cm的水泥地基)。 5. 要根据客户要求和现场具体情况布线,电线的外围都要套上PVC管。为了保证安全,电线 尽量走墙、高空。若必须走地下要PVC管必须套好防止漏水,并安装好空气开关以防止人身 安全事故。 6. 水泥台请使用C25等级以上混凝土浇筑...
  • Page 22 User Guide for Weather Station v1.0 2.2 避雷针安装 将避雷针,电木,引雷线按照下图组装(拆除立杆顶部 4 个螺栓后装入电木,再紧固螺丝) 避雷针与引雷线组装 避雷针、电木固定 警告 避雷针为可选设备。如用户因未安装避雷针导致设备损坏,我公司概不负责。 避雷针为危险物品,安装前请将其存储在隐蔽地点,避免意外伤害。 若安装位置附近 20m 以内有避雷设备,可不装避雷针。 若安装在野外,请务必安装避雷针! 2.3 总辐射传感器的安装 1、将总辐照传感器与一体式传感器连接(如下图连接) 安装步骤:...
  • Page 23 User Guide for Weather Station v1.0 1、拧开总辐照传感器保护盖。 2、水平辐射仪同理用水平面辐射传感器固定横臂,固定在支架上。 2.4 一体式传感器安装 安装一体式传感器前,请先确认指北标识方向需指向正北方。...
  • Page 24 User Guide for Weather Station v1.0 2.5.1 无避雷针情况下的安装方法 若您未选择安装避雷针,请将一体式传感器直接安装在立杆支架上; 若您选择安装避雷针,请将一体式传感器安装在横臂上 无避雷针固定图示 有避雷针固定图示 2.5 接线箱安装 将接线箱固定在立杆支架上,并紧固螺母...
  • Page 25 User Guide for Weather Station v1.0 3. 气象站接线 3.1 传感器接线 安装步骤: 1.连接一体式传感器 将电箱传感一体线接温湿度传 感器上 警告 1.严禁在接线过程中连接电源 3.2 采集器与气象站接线 6. RS485 连接:将电源箱内标记 485A 的绿线,485B 的蓝线线分别与采集器 A、B 端口相连...
  • Page 26 User Guide for Weather Station v1.0 2.采集器电源连接:将电源箱内标记"DC12V"的红线连接到采集器"+",标记"GNG"的黑线连 接到采集器正负极电源输入端 1. 检查接线是否正确 接线完成示意图...
  • Page 27 User Guide for Weather Station v1.0 2. 按照接线柱 L、N 指示,连接火线和零线(连接后确定接线无错后再上电),上电后指示 灯常亮。 警告 3. 检查所有接线无误后,再通电。 4. 确保直流接线正确,否则会损坏采集器。 3. 拧紧防水帽。 SOLARMAN APP 使用指南...
  • Page 28 User Guide for Weather Station v1.0 1.下载 app 苹果手机:在苹果商城里搜索 “SOLARMAN Smart” 安卓手机:在谷歌应用商店搜索“SOLARMAN Smart” . 你也可以登录网页版: home.solarmanpv.com pro.solarmanpv.com 2.注册 去 SOLARMAN Smart 和注册。单击“注册”并在此处创建帐户。 3.创建一个电站 单击“立即添加”创建电站。请在此填写电站基本信息和其他信息。...
  • Page 29 User Guide for Weather Station v1.0 4.添加设备 方法一:手工输入采集器序列号。 方法二:点击右边的图标,扫描输入采集器 SN。 5.网络配置(WiFi 类采集器需执行此步骤,GPRS/4G 类采集器可跳过此步骤) 添加采集器后,请配置网络以确保正常运行。进入“电站详情”-“设备信息”,找到目标...
  • Page 30 User Guide for Weather Station v1.0 序列号并单击“联网”。 步骤 1:确认 Wi-Fi 信息 请确保手机已经连接家中的 Wi-Fi 网络,与页面上显示的网络一致,并输入该网络的连接 密码。完成输入并确认信息无误后,点击“开始配置”按钮。 注意: 5G 网络禁止使用。 网络中避免使用以下特殊字符(, ; = “ ” ’) WiFi 步骤 2:连接采集器 AP 网络 根据页面上的提示, 您现在需要将手机连接至网络“AP_XXXXXX”。 请点击“去连接”按钮,...
  • Page 31 User Guide for Weather Station v1.0 在「手机系统 WLAN 页面」中,连接至此网络。成功连接后,请返回至 APP。 步骤 3:等待配置完成 成功连接采集器 AP 网络并返回 APP 后, 将会进入到如下页面, 请耐心等待配置自动完成。 若页面提示配置成功,您返回「设备列表」后,采集器将依然为“离线”状态,一般 10 分 钟内, 设备即可以正常通信, 开始采集光伏系统的数据, 然后由“离线”状态更新为“在线” 状态,请耐心等待。 如果配置失败,请检查以下原因 再试一次。...
  • Page 32 User Guide for Weather Station v1.0 (1) 确保 WLAN 已打开。 (2) 确保 WiFi 正常。 (3) 确保无线路由器没有实现白名单。 (4) 删除 Wi-Fi 网络中的特殊字符。 (5) 缩短手机和设备之间的距离。 (6) 尝试连接到其他 Wi-Fi。 质保卡 尊敬的用户 : 您好!感谢您购买无锡英臻科技有限公司的产品,为了更好的为您服务,在购买产品后,请 认真阅读,填写并妥善保管好此质保 此证不得涂改,否则视作无效凭证卡。 用户名 联系人 购买日期 联系电话 产品名称/ 产品序列号 型号 用户地址 维修记录 日期...