Instructions for installation, use and maintenance – ENG
Adveco S6÷S36 Electric Boilers
Electric block-boiler for heating systems with thermoregulatory microprocessor
FU- Adveco-08.2022.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Adveco S6

  • Page 1 Instructions for installation, use and maintenance – ENG Adveco S6÷S36 Electric Boilers Electric block-boiler for heating systems with thermoregulatory microprocessor FU- Adveco-08.2022.
  • Page 2: Table Of Contents

    Waste disposal 2.10 Scope of delivery 2.11 Factory data plate 2.12 Dimensions and technical data 2.12.1 Dimensions and technical data for boiler Adveco Standard 2.12.2 Technical data 3. Transportation 4. Device installing Warnings before mounting Distances De-mounting of front casing...
  • Page 3: Description Of Symbols And Instructions For Safe Work

    Description of symbols and instructions for safe work Description of symbols and instructions for safe work Description of symbols Instructions for safe work Warnings General safety instructions Non-compliance with safety instructions may cause heavy Warnings in text are marked by gray triangle, injuries –...
  • Page 4: Cleaning And Maintenance

    Description of symbols and instructions for safe work Instructions for service Life threat of electric power shock  Inform users about mode of work of device and instruct  Secure electric power connecting is done by authorised them in maintenance service! Comply with connecting scheme ...
  • Page 5: Device Data

    Reduce heat transmission experience. Typology Norms, regulations and standards These instructions are related to the following kind of device: Adveco Standard This product is in compliance with the following regulations: 6÷36kW –  50110-1:2013 Operation...
  • Page 7 Device data Minimum distances burnable Product description construction materials Basic components of boiler:  Boiler body Depending on valid regulations, other minimum distances  Device frame and casing could be applied, different than mentioned below.  Control unit Comply with regulations of electrical installations and ...
  • Page 8 Device data Return boiler’s line Terminal for room thermostat 1 IN 2 OUT Start boiler’s line Microprocessor plate LCTR2 Boiler’s exchanger Electric heater contactors Temperature sensor Electric heaters Safety thermostat (STB) Safety assembly for connecting the power cord Control panel with display LCI2 Terminals for connection, neutral (N) and protective (PE) lines Connection ½˝...
  • Page 9: Environment Protection / Waste Disposal

     Check if packaging is damaged during delivery  Check if delivery is complete Part Pieces Boiler Adveco standard Assembly Set Instructions for handling 2.11 Factory plate Factory data plate is placed on the external side of the boiler and contains the following technical data: ...
  • Page 10: Dimensions And Technical Data

    Device data 2.12 Dimensions and technical data 2.12.1 Dimensions and technical data for Adveco Standard Electric boiler Adveco Standard 6÷24kW Adveco Standard 30÷36kW  Image 2: Dimensions Adveco Standard 24kW and 36kW...
  • Page 11: Technical Data

    Device data 2.12.2 Technical data UNIT S 18 S 24 S 30 S 36 Power Usability level Number of power grades 3×2 3×3 3×4 3×6 3×8 3×10 3×12 Division of power grades V AC 3N ~ 400/230V 50Hz Network voltage Ingress Protection rating IP20 HxLxW...
  • Page 12: Transportation

    Transportation Transportation NOTE: Transport damages Pay attention on instructions for transportation on packaging Use adequate transportation means, i.e. carts for bags with tighten strip. The product should be in horizontal position during transportation Avoid shocks or collisions  Packed boiler put on carts for bags if needed secure it with strip and drive it to its mounting place ...
  • Page 13: Distances

    Installation Installation of device Distances CAUTION: Human or material damages occurred because of irregular installation! Never install boiler without expansion dish (AG) DANGER: Fire threat due to burnable materials and safety valve and liquids! Boiler must not be installed in protective zone of Do not dispose burnable materials and liquids important area or at the place of bath close to the boiler...
  • Page 14  Connect return line on connection IN  Connect start line on connection OUT Systems on which the Adveco Standard boiler can be connected  All systems for heating the space designed for 80/60 temperature regime (or lower)  Closed heating systems ...
  • Page 15: 4.7.2 Heating Pump Air Emission And De-Blocking

    Filling the installations and watertight testing NOTE: Material damage due to temperature tension. The Adveco Standard boiler does not contain a If you fill the boiler in hot condition, manometer, so when filling the installation with water, temperature tension can cause cracks the pressure must be monitored on the manometer due to tensions.
  • Page 16: Positions Of Introducer For The Introduction Of The Power Cable

    Electric connecting Electric connecting When connecting boiler on electric installation take DANGER: Life threat from electric shock! care on connections scheme and connecting plans. Respect mandatory diameters of cables and fusses Electric works must be done only by power outside the boiler qualified person Turn off voltage supply before opening This device is manufactured for connection to three-...
  • Page 17: Connecting Power (Voltage) Cable

    Electric connecting Connecting power (voltage) cable  Neutral (zero) duct line is connected to corresponding row immobilizer (N). Row immobilizer of zero duct line is of blue colour  Commencing should be performed according to the mounting scheme as given in the image 7,8,9,10,11 ...
  • Page 18: Connect Boiler's External Control (Room Thermostat)

    Electric connecting Image 8: NOARK fuses Image 9: NOARK fuses Scheme of boiler connecting to mono-phase power supply Scheme of boiler connecting on three-phase power supply – ONLY FOR POWER OF 6kW AND 9kW NOTE: When there is only an electric boiler in the heating system, it is recommended to connect the external circulation as in Figures 7a, 7b, 8, 9. The pump connected in this way is controlled by a microprocessor thermostat.
  • Page 19 Electric connecting Electric schemes of connection All quoted cross-sections of cables are minimal. Cross-sections that should be placed depend on length of the line and placing mode.  Cable cross-sections should be dimensioned according to  local regulations Legend Legend 3P A Three-pole automatic fuse LCTR 2...
  • Page 20 Electric connecting Image 12a: Boiler electric scheme Adveco Standard with nominal power of 6kW...
  • Page 21 Electric connecting Image 12b: Boiler electric scheme Adveco Standard with nominal power of 9kW and 12kW...
  • Page 22 Electric connecting Image 13a: Boiler electric scheme Adveco Standard with nominal power of 18kW...
  • Page 23 Electric connecting Image 13b: Boiler electric scheme Adveco Standard with nominal power of 24kW...
  • Page 24 Electric connecting Image 14: Boiler electric scheme Adveco Standard with nominal power of 30kW and 36kW...
  • Page 25: Commissioning

    Commissioning Commissioning When complete below described works fill First turn on Commissioning log (chapter 6.3). NOTE: Material damage due to incorrect Before commissioning handling! Instruct client/user how to handle device NOTE: Material damage occurred due to unprofessional operating! Start-up without sufficient quantity of water ...
  • Page 26: Overview Of The Elements To Adjust

    Overview of the elements to adjust 7.2.1 Device functions  Adveco Standard is a classic type of electric boiler, without a circulation pump and expansion vessel. The construction of Adveco Standard is robust, and the built-in components are of top quality. It is enriched with a microprocessor thermoregulator, which is the most important difference compared to the previous model.
  • Page 27 Heating installation handling Regulation of heating 7.3.2 Boiler given power adjusting  Circulating pump and electrical heaters turn on by command of room thermostat Use the ‘‘-’’ or ‘‘+’’ buttons to select the mode for setting the  When boiler reaches set temperature of water in the default power - the LED next to the "Sets power"...
  • Page 28 Heating installation handling 7.3.3 Low temperature warning If temperature of the system decreases to T≤4 °C, the boiler continues to work normally, but measuring temperature indicator starts to flash slowly (image 21). It is necessary to increase temperature to T≥5 °C in order to stop automatic flashing of warning indicator.
  • Page 29 Heating installation handling 7.3.4 Warning with high temperature If temperature increases to T≥100 °C, display of its value is not If temperature of the system increases to T≥85°C, the pump possible to see on the screen so in this will appear code EH works continually (due to taking heating energy through pipe meaning that temperature is T≥100 °C (image 26).
  • Page 30 Heating installation handling 7.3.5 Signal and code of warning and mistakes ☼ Temp. - slow flashing - Warning: lower limit exceeding (T≤4 °C) or upper limit (T≥85 °C) of temperature of the heating system Measure: Check if valves are open, the functionality of circulation pump and relay/contactor ☼...
  • Page 31 Heating installation handling 7.3.6 Room temperature regulator This device is not designed for work without room temperature regulator. Room thermostat must be installed in reference room. Managing temperature of all rooms is done by this remote control. Radiators in reference room should not be equipped by thermo-static valves or these must always be open.
  • Page 32 Cleaning and maintenance Cleaning and maintenance Establish a working pressure of at least 1 bar, DANGER! Life threat of electric power shock! depending on the height of the highest point of the Electric power work must be done only by installation.
  • Page 33 Cleaning and maintenance Inspection and maintenance The commissioning, inspection and maintenance record serves At least once a year perform maintenance or when a as an attachment for copying check shows the status of installations that require  Executed works should be authorised by signature and maintenance date Date:...
  • Page 34 Environment protection/Waste disposal Environment protection /Waste disposal One of the basic concepts of business is environment protection. Quality of products, thriftiness and environment protection are equally valuable goals for us. It is critical to strictly comply with law and regulations on environment protection.
  • Page 35 Troubles and troubleshooting Troubles and troubleshooting Troubleshooting on regulations and hydraulics must be done by an authorised firm For repairs use only original spare parts TROUBLE DESCRIPTION CAUSE MEASURE  Provide power supply  Boiler is out of power supply ...
  • Page 36 12. Product data sheet (in accordance with EU regulation no. 811/2013) Manufacturer MIKOTERM DOO Brand name Adveco Standard Models Adveco Standard 6kW Adveco Standard 9kW Adveco Standard 12kW Adveco Standard 18kW Adveco Standard 24kW Adveco Standard 30kW Adveco Standard 36kW...
  • Page 37 Notes...
  • Page 38 Contact Details The Adveco Electric Boiler range, this manual, and all information contained within, are supplied by Adveco Ltd. Adveco Ltd. Unit 7&8 Armstrong Mall, Southwood Business Park, Farnborough, Hampshire, GU14 0NR T: 01252 551 540 enquiries@adveco.co www.adveco.co Adveco Sales Department...