Samlexpower SDC-12 Instruction Manual page 2

24 vdc to 12vdc converter

Advertisement

SPECIFICATIONS
CAUTION! : THERE IS NO ISOLATION BETWEEN THE INPUT AND THE OUTPUT.
INPUT AND OUTPUT HAVE A COMMON NEGATIVE
Input to output isolation
Input voltage
Output voltage
Output voltage regulation
Input current at no load
Output current
Continuous
Current limit *
*Note: In current limit condition, the output voltage will drop if the
current drawn increases beyond the current limit value of 5.5 A
Output ripple and noise
Efficiency
Operating ambient temperature -
Humidity
Protections:
- Overload
- Over heating
- Reverse polarity
- Over voltage
Input side fuse
Safety and EMC Standards:
- Emission
- Immunity
- Automotive directive
Input / output connections
Weight
Dimensions (H x W x D)
Warranty
NOTE: Specifications are subject to change without notice
SDC12-May 2008
Not isolated. Input and output connections have a common negative
20 to 32 VDC
13.6 VDC ± 0.1 V
3%
< 5 mA
12 A
12.5A
less than 50 mV RMS
Approx. 92%
o
-20 to +30
C (derate linearly to zero at 70º C)
Max. 95%, non condensing
By current limiting
Drop in output voltage
Fuse protection, 10A
Varistor (also protects against load dump)
10 A (inside the unit)
EN50081-1
EN50082-1
95/54/CE
Terminal Block - 6.3 mm male flat tab, quick connect
0.6 lbs / .25 Kg
1.9" x 3.9" x 2.7" / 49 x 88 x 98 mm
2 years
Samlex America Inc.
110-17 Fawcett Road
Coquitlam BC Canada V3K 6V2