# IMPORTANT SAFETY INSTRUCTIONS
# GENERAL INSTRUCTIONS
# INSTALLATION INSTRUCTIONS -PHOTOVOLTAIC MODULES-
# ELECTRICAL OUTPUT AND THERMAL CHARACTERISTICS
# ANNEX (NORMATIVE)
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety instructions for the PV module
that must be followed during the maintenance of PV modules.
To reduce the risk of electric shock, do not perform any servicing
unless you are qualified to do so.
1.
The installation must be performed by a certified installer
/servicer to ensure system integrity and safety.
2.
The
installation
is
understanding of this INSTALLATION MANUAL. If you don't
have your personal copy, please contact your installer or local
SHARP
office
listed
https://www.sharp.eu/
3.
Do not pull the PV cables.
4.
Do not touch any surface of PV module.
5.
Do not place/drop objects onto the PV modules.
6.
Do not disassemble or attempt to repair the PV module by
yourself.
7.
Do not drop the PV module.
8.
Do not damage, pull, bend, or place heavy material on cables.
9.
Upon completion of any service or repairs, ask the
installer/servicer to perform routine checks to determine that
the PV modules are in safe and proper operating condition.
1. INTRODUCTION
This INSTALLATION MANUAL contains essential information for the electrical and mechanical installation that you must know
before installing SHARP PV modules. This also contains safety information you need to be familiar with. All the information
described in this manual are the intellectual property of SHARP and based on the technologies and experiences that have been
acquired and accumulated in the long history of SHARP. This document does not constitute a guaranty, expressed or implied.
SHARP does not assume responsibility and expressly disclaims liability for loss, damage, or expense arising out of or in any way
connected with installation, operation, use or maintenance of the PV modules. No responsibility is assumed by SHARP for any
infringement of patents or other rights of third parties that may result from use of PV module. SHARP reserves the right to make
changes to the product, specifications or INSTALLATION MANUAL without prior notice.
2. COMPONENTS
Connector
Junction Box
Frame
INSTALLATION MANUAL
- Crystalline Photovoltaic Module -
only
allowed
after
referring
in
SHARP
Solar
web
GENERAL INSTRUCTIONS
Solar Photovoltaic Cell
Electriclal Cable
Glass
MODEL
NU-JC415
10. When
replacement
installer/servicer uses parts specified by the manufacturer with
same characteristics as the original parts. Unauthorized
substitutions may result in fire, electric shock, or other hazard.
11. Consult your local building and safety department for required
permits and applicable regulations.
12. As a result of sliding snow, the mechanical load increases when
and
the number of PV module rows in the matrix of a PV installation
increases. When mounting the PV module in the portrait
orientation for more than 3 rows, the accumulated snow load
site:
may cause the lower edge of the PV module frame to deform.
Take necessary measures (e.g. snow stopper) to avoid
possible damage.
13. Periodically remove any overhanging snow and/or ice from the
PV module framework as it may cause deformation of the PV
module frame.
CAUTION: HIGH VOLTAGE
To reduce the risk of electric shock, do not touch.
3. GENERAL INFORMATION
(INCLUDING WARNING AND SAFETY)
The installation of PV modules requires a great degree of skill
and should only be performed by a qualified licensed
professional, including licensed contractors and licensed
electricians. Please be aware that there is a serious risk of
various types of injury occurring during the installation including
the risk of electric shock. All SHARP PV modules are equipped
with permanently attached junction boxes that will accept
variety of wiring applications or with a special cable assembly
for ease of installation, and they do not require special
assembly.
GENERAL WARNING
1.
PV modules are heavy. Handle with care.
2.
Before you attempt to install, wire, operate and maintain
the PV module, please make sure that you completely
understand
INSTALLATION MANUAL.
3.
Contact with electrically active parts of a PV module such
as terminals can result in burns, sparks and lethal shock
1
p.1
p.1 ~ p.4
p.4
p.5
p.6
parts
are
required, be
the
information
described
SIM02E-013
sure
the
in
this

Advertisement

loading

Summary of Contents for Sharp NU-JC415

  • Page 1 PV modules. No responsibility is assumed by SHARP for any infringement of patents or other rights of third parties that may result from use of PV module. SHARP reserves the right to make changes to the product, specifications or INSTALLATION MANUAL without prior notice.
  • Page 2: General Safety

    11. Do not touch the PV module with bare hands. The frame Use PV modules with the same cell size within series. of PV module has sharp edges and may cause injury. Follow all safety precautions of other components that are 12.
  • Page 3: Site Selection

    INSTALLATION MANUAL is still valid and proper for your To ensure proper system operation and to maintain your installation. The mounting method has been verified by SHARP guaranty, observe the correct cable connection polarity (Figures and NOT CERTIFIED by a third party organization.
  • Page 4: Maintenance

    SIM02E-013 The approved way to mount SHARP PV modules to a support mounted on rigid support structures. Deformation of support structure is described in this INSTALLATION MANUAL. structure may damage PV module with its electric performance. Although SHARP does not specify or warrant frame clamps or...
  • Page 5 (Pmax) (Voc) (Isc) (Vmpp) (Impp) configuration(*) shoc k NU-JC415 415W +5%/-0% 38,08V 13,87A 31,49V 13,18A 1.000V Ⅱ * The maximum series number of modules depends on the local conditions. These values are calculated under the condition of Voc at -40 °C.
  • Page 6 SIM02E-013 Annex (normative) 1. Spring washer 2. Washer Material: Stainless steel Material: Stainless steel Diameter: M8 8.2/15.4 mm Diameter: M8 8.5/15.5 mm Thickness: 2 mm (reference value) Thickness: 1.6 mm (reference value) 3. Bolt 4. Nut Material: Stainless steel Material: Stainless steel Size: M8 Size: M8 Diameter: M8 x 20 mm...