Operating Manual Circulating Type Liquid Cooling Equipment ORION Unit Cooler RKS250F1-S RKS400F1 CAUTION ●This product is designed for industrial use. Handle with care. ●Please read this manual carefully and operate this product accordingly. ●Retain this manual for future reference.
Page 2
Thank you for your purchase. Thank you for purchasing this Orion product. To ensure safe and efficient use, please install and operate this product in accordance with the instructions provided in this manual. Safety Precautions Before operating this product, be sure to read through the “Essential Safety Precautions” presented in this manual.
Essential Safety Precautions Usage Precautions (WARNINGS) WARNINGS Failure to observe the instructions contained in a WARNING may result in death or severe injury. Do not modify this product. Modification of this product will void the warranty. Do not attempt to carry out disassembly and repair yourself. Disassembly and repair must be carried out by the dealer or by qualified service specialists.
Page 5
Essential Safety Precautions Usage Precautions (CAUTIONS) CAUTIONS Failure to observe the instructions contained in a CAUTION may result in injury or physical damage. Do not feed incorrect liquid into the product. This product is designed to operate with fresh water (compliant with the water standards developed by the Japan Refrigeration and Air Conditioning Industry Association, see page 27) or with an ethylene-glycol water solution that has a concentration of 30 to 40%.
Essential Safety Precautions Warning Label on the Product Warning Label on the Product The warning labels shown below display important warnings, and the label on the front of the chiller displays particularly important warnings. Be sure to read these warnings before operating this product. If the labels become worn or damaged in any way, contact your dealer for a replacement.
Page 7
To Maintain Efficient and Trouble-Free Performance 3. Note the operating ranges and always operate the product within these ranges. Operating outside the specified ranges can damage the product. RKS250F1-S RKS400F1 Working water temp. range (℃) 5 ~ 25 Ambient temp. range ...
Page 8
To Maintain Efficient and Trouble-Free Performance 10.The water level in the tank may drop due to long piping, or operation of the product for the first time. In such cases, stop the product, replenish the water, and restart the product. 11.
Machine Layout External Appearance External Appearance ■ External view (Front) Pump-priming port (Pump-priming port cap) Specification plate Control plate Water outlet Rp3/4 Drain port M10 Power cord access hole φ30 (incl. grommet) (Drain plug) Water inlet Rp3/4 (Back) Condenser filter and condenser...
Page 10
Machine Layout Control Plate Control Plate ① ② ③ ④ ⑤ ⑥ ① Digital Display Measured water temperature(normally displayed) Alarm(error) code display (flashing) ② Cooler operation lamp ON : Running ○ OFF : Product stopped ③ Cooler ON/OFF switch Operation/stop of chiller.
(RKS250F1-S) ● Do not start or stop the unit by plugging in or unplugging the power cord. Doing so can lead to an electric shock or shorts. (RKS250F1-S) CAUTION ● Do not loosen the priming water cap while the product is operating. Loosening the cap could allow air to enter the pump, resulting breakdown due to running dry.
Page 12
Operating Procedures If Starting Up For the First Time, or After Prolonged Periods of Non-Use If Starting Up For the First Time, or After Prolonged Periods of Non-Use Please note the following points before starting the product for the first time, or when restarting it after a long period of non-usage.
Page 13
■ Checking the Water Level Confirm there is water in the water tank. Add water to the water tank. The amount of water should be at least the amount of water shown in the following chart. RKS250F1-S RKS400F1 Required water tank volume (L) ...
Page 14
Operating Procedures Local Operation Mode (Operation Using the Control Panel) Local Operation Mode (Operation Using the Control plate) The product can be controlled locally if parameter "F2" is set to either "0" or "2". (The factory default setting is "2".) If parameter "F2" is changed, parameter "F1" will automatically be reset at the same time. Therefore, after changing "F2", check the value of "F1"...
Page 15
Operating Procedures Local Operation Mode / Remote Operation mode ■ Circulation Pump Independent Operation 1.While pressing the temperature adjust switch ▲, press the cooler ON/OFF switch. The cooler operation lamp will flash, the digital display will show “ ”, and the circulation pump will be operating.
Page 16
Operating Procedures Dual Mode (Operation in Combination of Local and Remote Modes) Dual Mode (Operation in Combination of Local and Remote Modes) If parameter “F2” is set to “2” (factory default setting), then the product can be operated as follows: ■ Starting The Product 1.When the remote switch is OFF (terminals 14 and 15 are open), and the product is not running :...
Page 17
Operating Procedures Other Operations Other Operations ■ How to Confirm the Temperature Setting 1. Press the "SET" switch. The water temperature setting will show on the digital display for several seconds. ■ How to Clear an Alarm 1. Press the "RESET" switch. After removing the actual cause of the alarm, pressing the reset switch will clear the alarm.
Page 18
Operating Procedures Other Other IMPORTANT ● If signal outputs are to be used, please ask your dealer or other qualified person to perform the required wiring and installation. ■ Operating Signal The signal will be output from when the product is turned on by pushing the ON/OFF switch, and will continue to be output until the ON/OFF switch is pushed again to stop the product.
(RKS400F1) compressor motor. If activated, the electric circuit will be cut off and Motor the compressor operation to be stopped. protector (RKS250F1-S) Compressor This safety function will be activated if there is overload an abnormal overheat condition in the protector...
Monitoring Displaying Refrigerator State Displaying Refrigerator State This product can display operational data in the digital display on the control plate. 1. Hold down the SET switch on the control plate for 7 seconds to switch the temperature setting blinking on the digital display to alternate between "...
Parameters Setting and Changing Parameters Setting and Changing Parameters Various functions of the product can be selected by changing parameter settings. ■ Parameter Setting Overview Example: Display and change the “F5” parameter (Audible alarm enable/disable). (This example will show to change the audible alarm from the factory default setting of “1” to “0”.) Doing so switches to the parameter display mode.
Page 22
Parameters Parameter Types and Functions Parameter Types and Functions ■ Parameter List (Settings can be changed while the product is running, except for “F15”.) Parameter Setting Min. set Factory default Description Units Number range value setting Power-cutoff recovery setting 0 ~ 2 ―...
Page 23
Parameters Parameter Types and Functions ● ”F2” Local / Remote operation priority select (relevant parameter “F1”) Selects the active ON / OFF switch (cooler ON / OFF switch) between the (local) control plate or remote control switch. “F2” set value Description “F1”...
Page 24
Parameters Parameter Types and Functions ● "F20" Water temperature upper/lower limit warning enable (Relevant parameters: "F21", "F22", and "F23".) Set this parameter to detect abnormal water temperatures. Set specific detection temperatures in parameters "F21", "F22", and "F23". “F20” set value Description Alarm detect disabled Incl.
Page 25
Parameters Parameter Types and Functions ● "F22" Water temperature upper/lower limit warning upper limit value (relevant parameters: "F20" and "F23"). Can be set if "F20" is set to "3" or "4". Regardless of the set water temperature, if the water temperature goes above this value, the alarm will be output.
Inspection and Maintenance Every Week WARNING ● Never operate switches with wet hands, and never touch electrical components. Improper handling may result in electric shock. WARNING ● Do not use water to clean this product, and do not allow water to spill onto or in the vicinity of this product.
Page 27
Inspection and Maintenance Bimonthly Inspection and Maintenance / Monthly Inspection and Maintenance Bimonthly Inspection and Maintenance 1. Inspection for drain port leakage ※ If water leakage is detected, check for scratches or breaks and consult with your dealer. Replace the drain gasket if it is scratched or deformed. 2.
Page 28
Inspection and Maintenance Monthly Inspection and Maintenance / Every half year 4. Clearing a " " 500-hour Filter Use Caution Alarm After cleaning condenser and the filters, clear the operating-hour timer for " ". ● Clearing the " "500-hour Filter Use Caution Alarm operating-hour timer ①Hold down the RESET switch on the control plate for 5 seconds or longer.
Water Quality Management CAUTION 1. Chilled water should be either clean water (tap water) or a 30 to 40% solution of industrial use ethylene glycol in water. Use of non-approved water can result in damage to the product, leaking, and possible electric shock or electrical shorts.
Page 30
Water Quality Management 3. Refer to the following chart in order to avert future trouble. Condition of working Description of trouble Procedures to take water working water ORION's water quality standards The presence of chloride ion or other corrosive chloride other designed...
Troubleshooting Troubleshooting Charts WARNING ● If the product behaves abnormally, switch it off and then cut the power. Then contact your dealer or product specialist. Continuing to run the cooler while operation is abnormal may result in fire or electric shock. CAUTION ● ...
Page 32
Manual ○ × Running displays Compressor overcurrent relay(RKS400F1) Alternate All stopped × ○ Compressor overload protector(RKS400F1) Manual displays Compressor motor protector(RKS250F1-S) Alternate High pressure switch Manual × ○ All stopped displays Alternate Compressor intake temperature sensor Manual × ○ All stopped...
Page 33
MP: Compressor motor ・Confirm whether or not there was a momentary loss of power or voltage drop from the power source. protector(RKS250F1-S) ・Clean the condenser fins and filter. ・Bring the water and ambient temperatures to within specified PRS: High pressure switch levels.
Page 34
Troubleshooting Chart : Circulation pump flow-rate and required water tank volume RKS250F1-S RKS400F1 Circulation pump flow-rate(L/min) At least 15 Required water tank volume(L) At least 10 At least 20 IMPORTANT ● If one of the built-in safety devices activates, press the RESET switch, conduct the appropriate measures as noted above, and then restart operation.
Page 35
The screws holding the cabinet (2 points) ■ Distribution Box RKS250F1-S RKS400F1 Fuse Fuse Reset switch with compressor overcurrent relay...
Storing the Product (Preparing winter or for other extended period of non-use) 1. Switch OFF the breaker. Cut off the power source. (Switch off the power source breaker.) 2. Drain water from the pipes (including the main unit and the water tank.) (1) Drain the water from the water tank.
03091816010 Filter assembly Condenser filter (for RKS400F1) 18502113040 Glass fuse For controller (125V 1A RKS250F1-S) ―― Fuse is blown 18502123040 Glass fuse For controller (250V 1A RKS400F1) ※2 Indicates the time when the chance of failure due to wear increases. ※The specific maintenance cycle will depend on factors such as the operating environment and therefore components might not require replacement at the exact listed times but should be replaced when any abnormality arises.
Approximate interval time when it becomes necessary to replace the parts depending on conditions of use Pieces/product Part Number Part Name Remarks ※ Maintenance cycle 0A002804000 For RKS250F1-S Compressor 0A003003000 For RKS400F1 0A000673010 For RKS250F1-S Fan motor 20,000h 0A000736000...
■ About functionality service components: ● Functionality service components are parts required for maintaining the product's functionality. ● Orion will maintain the functionality service components for this product for at least 7 years after its production termination. ■ How to request after-sale services ●...
Page 40
Installation Guide Installation of this product should be performed by your dealer or other qualified personnel. Improper installation by the user could result in water leaks, electric shock, or fire. Contents Essential Safety Precautions ..........39 Moving the Product to the Installation Site ......41 Installation .................
Essential Safety Precautions Usage Precautions (WARNINGS) WARNINGS Failure to observe the instructions contained in a WARNING may result in death or severe injury. Be sure to install this product in accordance with the instructions given in this manual. Improper installation may lead to water leakage, electric shock, or fire. Installation should be carried out by your dealer or by a qualified installation engineer.
Page 42
Essential Safety Precautions Usage Precautions (CAUTIONS) CAUTIONS Failure to observe the instructions contained in a CAUTION may result in injury or physical damage. Be sure that the installation site is sufficiently strong to bear the full weight of this product. The product must be installed so that it is level, and must be secured into place so that it cannot be accidentally overturned.
Moving the Product to the Installation Site Initial Check / Moving the Product to the Installation Site Initial Check Upon receiving the product, check it carefully for signs of shipping-related damage (scratches, dents, etc.). If you notice a problem, please contact your dealer. ...
Installation Installation Site WARNING ● Installation should be carried out by your dealer or by a qualified installation engineer. Installing this product on your own may result in water leakage, electric shock, or fire. Installation Site WARNING ● Do not install in areas where flammable gas leaks may occur. Presence of flammable gas around this product may result in fire. ...
Page 45
If such measures are to be taken, ensure that such construction does not result in a drop in fan air flow. RKS250F1-S RKS400F1 Fan air flow(㎥/min)50 / 60Hz 10.5 / 11.5...
Page 46
Piping Installation CAUTION ● Make sure that piping is installed reliably and correctly. Failure to do so can result in water splashing on nearby items. 1. Water piping RKS250F1-S RKS400F1 Water tank capacity (L) At least 10 At least 20 Inlet port size...
Page 47
Installation Piping Installation 5. Keep piping distances as short as is feasible, and keep rises and bends to a minimum. (Keep below the maximum head loss, including during start times.) RKS250F1-S RKS400F1 Maximum head loss (m) 50/60 Hz 2/3 6. Water inlet and outlet piping installation (connecting included...
Page 48
Installation Piping Installation (5) Perform installation so that there are no water or air leaks in any of the piping. Air leakage on the intake side water pipe can result in air entering the pump causing it to lose prime (run dry). (6) Connection method and names of included parts (※...
Page 49
Installation Wiring Work Wiring Work WARNING ● Electrical work should be carried out in accordance with the instructions given in this manual, using dedicated circuitry only. Improper workmanship or insufficient electrical capacity may result in electric shock, fire, or other hazard. ● Be sure to use specified cable types.
Page 50
Installation Wiring Work ■ Distribution box RKS250F1-S Remote control terminal (14,15) Signal output terminal (10,11,12,13) Ground RKS400F1 Remote control terminal (14,15) Signal output terminal (10,11,12,13) ...
Page 51
1.The power capacity of the power cord to the product must meet the maximum operating current specifications listed in the chart below. Always properly connect the Its own earth leakage ground wire. (An earth cord is accessories for RKS250F1-S) breaker installed which RKS400F1 ...
Page 52
Installation Wiring Work ■ Setting Up to Use Remote Operation and External Signals The product accepts input of a remote-control drive signal, and generates output of a drive signal and alarm signal. If you wish to use these signals, please refer to the specifications below and connect up the wiring accordingly.
③ H ose clamp (φ32 wire type) : 2 pieces ④ A wire for remote terminals connection (70mm) : 1 piece ⑤ A power cord with a plug.(2300mm) (For RKS250F1-S) ⑥ A n earth cord.(2300mm) (For RKS250F1-S) ※ Required water tank volume 10L or larger.(For RKS250F1-S)
Page 59
(2) In principal, the owner of the product will confirm diagnosis of the breakdown according to the operating manual. However, there might be cases where this work may be carried out instead by a member of ORION's service network. In such cases, there will be no charge where the cause of the breakdown lies with ORION.