Pacific GSM DIN-4G Instructions Manual

Pacific GSM DIN-4G Instructions Manual

3g/4g network communicator

Advertisement

Quick Links

3G/4G Network Communicator
Instructions: April 17, 2022, refers to the firmware version: 1.1.0 and software version 1.0.1
DIN-4G controller is a new version of Pacific GSM communicator The
new version of Pacific GSM DIN communicator is based on 3G/4G
module with four inputs, four outputs and two temperature inputs to
suits most basic applications such as monitoring process, status of
large variety of equipment's in multiple industries or switching
remotely any device via custom text message or drop call.
Application can be quickly and easily switched or monitored
anywhere around the world via 4G/3G network thanks to our global
4G/3G module. Through DIN-4G communicator can be remotely
controlled such as lighting, pumps, garage doors and gates. May
indicate a fault, loss of liquid in tanks, emergency conditions, reboot
servers or simply using as a main power supply monitoring. DIN-4G
can be used as an alarm system with suitable sensors to protect
objects and spaces.
All easily through standard mobile phone
Basic specification:
DIN-4G module dimensions: 91 x 72 x 58 mm (H x W x D)
UMTS (3G) B1/B5/B8 (2100/850/900 MHz)
LTE (4G) B1/B3/B5/B8/B28 (2100/1800/850/900/700 MHz)
Power supply voltage: 100- 250V AC with battery back up
Back up by internal Li-ion battery 3.7 V/550mAh
Current consumption – 4G module connected to network, standby: approx. 5mA
Max current consumption (4G module transmits): peak of 40mA max.
Operating temperature: -20°C to +50°C
4x logic input, activated connection/disconnection to GND
2x digital temperature input with a measuring range from -55°C to 125°C
2x relay NO/NC max load 5A 250V AC
2x transistor output open collector
USB-PC configuration with USB cable
10 authorized phone numbers can be set up
DIN-4G mounting for DIN rail
DIN-4G is designed in a dry environment. For outdoor installation, use the box with corresponding protection.
Basic Features:
Four universal inputs with adjustable reaction to change, connection or disconnection of the loop.
Inputs can be named (SMS text).
Each input can send 2 different TXT for remote status equipments
Inputs can be use for arming/disarming the communicator from remote device
Inputs regime arm/disarm or 24h. lop
Inputs for digital temperature sensor with automatic output control (thermostat).
Information SMS in case of exceeding the set temperature or the temperature drops below the set limit.
Power supply monitoring SMS notification if supply voltage reaches the set limits
4 outputs with multiple configuration options. Activation via TXT or call with timer option, siren, arm mode indication etc.
Device Status, you can always check the status via SMS.
DIN-4G

Advertisement

Table of Contents
loading

Summary of Contents for Pacific GSM DIN-4G

  • Page 1 • 10 authorized phone numbers can be set up DIN-4G mounting for DIN rail • DIN-4G is designed in a dry environment. For outdoor installation, use the box with corresponding protection. • Basic Features: • Four universal inputs with adjustable reaction to change, connection or disconnection of the loop.
  • Page 2: Led Indicator

    New Pre Pay SIM Card Activation It is recommended to only use new standard SIM cards with no data stored. DIN-4G has been tested with standard SIM cards provided by Vodafone NZ, Spark NZ, 2Degrees NZ, Telstra AU, Optus AU, Vodafone AU, AT&T USA, T mobile USA Place the new SIM card in an existing mobile phone.
  • Page 3 1 (NUMBER1). From this moment if the input 1 to 4 connected to GND for the DIN-4G module will send the pre-programmed SMS (DIN-4G: input 1-4 Activated) to this number, you can easily add additional phone numbers (up to 10) via simple PC configuration software or SMS com- mand.
  • Page 4 Setting DIN-4G communicator via PC configuration software Tab 1 – Contacts: The position of users in the system Username Set username Phone number Setting phone number of users Inputs 1,2,3,4 Setting inputs 1,2,3,4 notification options The activation of input will be reported via SMS...
  • Page 5 Tab2 - Setting of inputs: Input name Setting input name Activation text Text which will be send when input activated (connected to GND) Deactivation text Text which will be send when input deactivated (disconnected from GND)*the deactivation SMS text send only if logic setting is set to NC or status change Regime ARM / DISARM =SMS send only if communicator in arm mode...
  • Page 6 Tab3 – Setting of outputs: Output name Setting output name Activation text SMS command which will switch the output ON Deactivation text SMS command which will switch the output OFF Timer The output will be switched ON for the pre-set time. To control output ON/OFF only, the timer time must be set to a value 0:0:0 Confirmation SMS = After the output switched on or off via dialling or SMS the unit will confirm switching via SMS to the...
  • Page 7 Tab4 – Setting: Device Name To set device name (every SMS will start with this name) Password To set 4-digit password ARM Command To set command for arming the communicator DISARM Command To set command for disarming the communicator Tab 5 – Thermostat setting: Function Heating =Regulates heating Colling = Regulates Colling...
  • Page 8 Table 6 – Service setting: Temperature Monitoring Set the high and low temperature limits for notification via SMS to service number Delay Set the delay for sending notification when temperature out of limits (e.g. automatic defrost) Power Monitoring Set the notification via SMS in the event of a main power failure to service number Delay Outage Set the delay for sending notification when main power failure Delay Recovery...
  • Page 9: Sms Commands

    SMS commands are not case sensitive. E.g. command to determine the status, you can send STATUS / status / Status • If possible, always use the DIN-4G PC configuration software, it’s easy and intuitive Table 9 - SMS commands: STATUS...
  • Page 10 Table 10- Storing the users phone numbers: The DIN-4G Communicator can store up to 10 user mobile numbers which can be contacted via TXT or call if any inputs activated, temperature change or power supply fail and all stored users can control outputs via call...
  • Page 11 Table 12 - Digital input setting: Command: SETIN1 to SETIN4, send SMS: SETINX ABCDEFGHIJ (replace X for i corresponding input ) Parameter A A = 0 – Input is subject to activation / deactivation communicator A = 1 – Input is a 24-hour monitoring (permanent watch). A = 2 –...
  • Page 12 Table 14 - Setting the thermostat: Command: SETTHERM, send SMS: SETTHERM ABCDEFGHIJKLMNO Parameter A A = 0 - Thermostat is in the heating mode A = 1 - Thermostat is in cooling mode Parameter B Comfort temperature - sign. (can set the + or -) Parameter C Comfort temperature - hundreds °C.
  • Page 13: Radio Frequency (Rf) Exposure And Specific Absorption Rate (Sar)

    The SAR value is determined at the highest certified power level in laboratory conditions, but the actual SAR level of the DIN-4G Communicator while it is operating can be well below this value. This is because the DIN-4G Communi- cator is designed to use the minimum power required to reach the network.
  • Page 14: Disposal Of Old Electrical And Electronic Equipment

    The GSM Communicator was tested with SIM cards provided by “Vodafone NZ, Spark NZ, 2Degrees NZ, Telstra AU, Optus AU, Voda- fone AU, AT&T USA, T mobile USA”. Pacific GSM Limited cannot be held liable for any malfunction with the use of other SIM cards.

Table of Contents