JXCT JXBS-3001-EC User Manual

JXCT JXBS-3001-EC User Manual

Soil ec sensor

Advertisement

Quick Links

Analog Output
JXBS-3001-EC Soil Electric Conductivity Sensor User Manual
JXBS-3001-EC
Soil EC Sensor User Manual
Analog Output (4-20mA/0-5V/0-10V)
Version: 2.0
Date: 2020-01-05
Status: Released
www.jxct-iot.com
1 / 8

Advertisement

Table of Contents
loading

Summary of Contents for JXCT JXBS-3001-EC

  • Page 1 Analog Output JXBS-3001-EC Soil Electric Conductivity Sensor User Manual JXBS-3001-EC Soil EC Sensor User Manual Analog Output (4-20mA/0-5V/0-10V) Version: 2.0 Date: 2020-01-05 Status: Released www.jxct-iot.com 1 / 8...
  • Page 2: Brief Introduction

    Analog Output JXBS-3001-EC Soil Electric Conductivity Sensor User Manual I. BRIEF INTRODUCTION 1.1 Product Overview The soil conductivity sensor is suitable for measuring the total salt content (conductivity) of the soil. The soil conductivity sensor greatly facilitates the customer system's assessment of soil conditions. .
  • Page 3 Analog Output JXBS-3001-EC Soil Electric Conductivity Sensor User Manual 1.3 System frame Diagram FIGURE 1 SINGLE-ENDED FIGURE 2 MUTIPLE-ENDED 3 / 8...
  • Page 4: Hardware Connections

    Analog Output JXBS-3001-EC Soil Electric Conductivity Sensor User Manual II. HARDWARE CONNECTIONS 2.1 CHECKING BEFORE INSTALLATION Check the list of devices before installation: TABLE 2 List of Devices Name Number THE SENSOR DEVICE 12V POWER ADAPTER(Optional) WARRANTY CARD / CERTIFICATE 2.2 Interface Description...
  • Page 5 Analog Output JXBS-3001-EC Soil Electric Conductivity Sensor User Manual TABLE 3 Wiring Sequence Line Color Description Brown Power supply Positive ( 12-24V DC ) Power Black Power supply Negative White Voltage/current output Positive Gray Voltage/current output Negative Communication Blue Yellow We provide default cable length of 1.5meters, you can extend the cable yourself according to your needs.
  • Page 6: Wiring Instructions

    Analog Output JXBS-3001-EC Soil Electric Conductivity Sensor User Manual III. WIRING INSTRUCTIONS 3.1 Typical four-wire wiring Analog sensor wiring is simple, just connect the wire to the designated port of the device. The device supports 3-wire wiring. The following figure shows the voltage sensor connection mode. The power line (brown line and black line) of the sensor is connected to the power supply;...
  • Page 7 Analog Output JXBS-3001-EC Soil Electric Conductivity Sensor User Manual IV. ANALOG PARAMETERS MEANING AND CONVERSION 4.1 Analog 4-20mA Current Loop Current value 0us/cm 20mA 10000us/cm The formula is P = (I -4mA) *625us/cm (current) Where I is in mA. For example, the data Iout+ collected in the current situation is 8.25 mA, and the soil conductivity value calculated at this time is 2652.25 us/cm.
  • Page 8 Analog Output JXBS-3001-EC Soil Electric Conductivity Sensor User Manual For example, the data Vout+ collected in the current situation is 3515 mV, and the soil conductivity value calculated at this time is 3515 us/cm. 4.3 Analogue 0-5V voltage output Voltage value...

This manual is also suitable for:

Jxbs-3001-ec-i20

Table of Contents