Using these instructions
Please refer to all safety and installation requirements
detailed in the Quick start guide provided with the
HydroTap Command Centre, and HydroTap Command
Centre installation instructions found online, prior to
installation of, or any change to, the complete system.
Before commencing the
!
installation,download
& read the HydroTap
Read the
WARNING
Command Centre
instructions
installation instructions
Tools needed for tap installation
In addition to normal tools, the following (or equivalent
equipment) will be required.
35mm diameter sheet metal hole punch for sinks.
35mm diameter hole saw for worktops.
BC Compact
Tube spanner for fixing the tap assembly (supplied).
Be aware of the risks of hazards which could
!
cause harm when using tools. Assess the
risks before starting the installation.
Water supply pressure requirements
Min - Max pressure, kPA (bar)
HydroTap
170 (1.7) - 700 (7.0)
Sparkling
250 (2.5 ) - 700 (7.0)
HydroTap
Booster
200 (2.0) - 700 (7.0)
1
Positioning
Position the tap such that it
dispenses into the sink
bowl with clearance for a
cup or tea pot.
Wave Tap: Observe
100mm 360⁰ clearance
100mm
envelope.
Wave clearance
Ensure that taps are positioned to minimise
!
the risks of scalding when dispensing
boiling water.
Position Command Centre
and Tap as close together
as possible. See below.
InLine
E L E C T R O N I C
2
Cut the hole & fit the spacer
Cut a Ø35mm hole in the worktop / sink.
Apply a light smearing of silicone sealant on the
underside of the spacer to ensure a watertight fit.
Ø35mm
3
Mount the tap
Pass the tubes and USB cable through the Ø35mm
hole.
100mm
116mm
4
Secure the tap
Use a tube spanner to secure the tap in place.
Black
plastic spacer
Black
plastic spacer
Fixing
washer
Spider
clamp
Fixing nut
USB