Larson Electronics IND-CDL-SQ-10-FUVC-MP-1L-V1 Instruction Manual

Far-uv recessed 10" square light (1) 10w microplasma board, 222 nm uvc sanitation - recessed mount

Advertisement

Quick Links

(1) 10W Microplasma Board, 222 nm UVC Sanitation - Recessed Mount
Thank you for your purchase of the Larson Electronics IND-CDL-SQ-10-FUVC-MP-1L-V1.
EPA Reg. No 98409-1
EPA Est. No. 98409-TX-1
WARNING:
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CRITICAL SAFETY INSTRUCTIONS:
INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY
RELEVANT LOCAL BUILDING CODES.
RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF FIXTURE'S ELECTRICAL
SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.
BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE FIXTURE'S RATED VOLTAGE.
TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP
OBJECTS. SUITABLE FOR DAMP LOCATIONS.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
IN ACCORDANCE
WITH
CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.
WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS
PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION
SHEET, CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE.
WARNING: MAKE SURE POWER IS TURNED OFF BEFORE STARTING THE
INSTALLATION OR PERFORMING ANY MAINTENANCE.
RISK OF FIRE/ELECTRIC SHOCK –
RISK OF PERSONAL INJURY –
RISK OF BURN –
ALLOW FIXTURE TO COOL BEFORE SERVICING.
WARNING:
USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE.
CORD IS INTENDED TO ALLOW OPERATORS TO EXTEND POWER TO EQUIPMENT WHEN STATIONARY OUTLETS ARE NOT
READILY AVAILABLE.
IMPROPER USE OF THIS CORD, PLUG, AND RECEPTACLE CAN LEAD TO SERIOUS INJURIES OR DEATH TO
PERSONNEL.
PERIODIC INSPECTION OF THE CORD IS NECESSARY.
THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND,
THE CORD MUST BE REPLACED BEFORE RESUMING USE.
UV Warning
WARNING: ULTRAVIOLET LIGHT IS HARMFUL TO EYES AND SKIN. DO NOT STARE DIRECTLY INTO THE
ULTRAVIOLET BEAM WITHOUT WEARING PROTECTIVE GEAR TO PROTECT EYES FROM LONG TERM DAMAGE.
UNPLUG LAMP BEFORE SERVICING.
The Larson Electronics IND-CDL-SQ-10-FUVC-MP-1L-V1 Far-UV Recessed Square Light disinfects 99% of
viruses, bacteria, mold and spores from ceilings in occupied areas. This eye and skin safe disinfection unit uses
one 10-watt microplasma board that emits far-UV 222 nm germicidal light. Featuring an expected lifespan of 6,000+
hours, the unit is compatible with 120-277V AC, 50/60Hz.
Larson Electronics, LLC
Far-UV Recessed 10" Square Light
Instruction Manual
THE
IND-CDL-SQ-10-FUVC-MP-1L-V1
NATIONAL
DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.
FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY.
Phone: (800) 369-6671
ELECTRICAL
CODE
Fax: (903) 498-3364
IND-CDL-SQ-10-FUVC-MP-1L-V1
MUST
BE
AND
ALL
APPLICABLE
www.larsonelectronics.com
WIRED
LOCAL
THIS LINE
1 of 15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IND-CDL-SQ-10-FUVC-MP-1L-V1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Larson Electronics IND-CDL-SQ-10-FUVC-MP-1L-V1

  • Page 1 ULTRAVIOLET BEAM WITHOUT WEARING PROTECTIVE GEAR TO PROTECT EYES FROM LONG TERM DAMAGE. UNPLUG LAMP BEFORE SERVICING. The Larson Electronics IND-CDL-SQ-10-FUVC-MP-1L-V1 Far-UV Recessed Square Light disinfects 99% of viruses, bacteria, mold and spores from ceilings in occupied areas. This eye and skin safe disinfection unit uses one 10-watt microplasma board that emits far-UV 222 nm germicidal light.
  • Page 2 Gently push up trim and torsion springs so they begin to expand and lift trim in place. 4x Retaining Spring Clips Figure:2 2 of 15 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 3 Inspect for good working condition prior to storage and before re-use. REPLACEMENT PARTS The IND-CDL-SQ-10-FUVC-MP-1L-V1 is designed to provide years of reliable performance. Should the need for replacement parts arise, please contact Larson Electronics. THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS.
  • Page 4 2 Kolozsvári, Lajos; Nógrádi, Antal; Hopp, Béla; Bor, Zsolt. UV Absorbance of the Human Cornea in the 240- to 400-nm Range. Investigative Ophthalmology & Visual Science July 2002, Vol.43, 2165-2168 5 of 15 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 5 Far-UV 222 nm vs 254 nm: Safety and Germicidal Effectiveness...
  • Page 6: Table Of Contents

    Table of Contents 1.0 Executive Summary 2.0 Introduction 3.0 UV Light Sanitation 3.1 How Does UV-C Light Sanitation Work? 4.0 Far UV-C 222 nm 4.1 UV 222 nm Wavelength Properties 4.2 Safety Considerations 4.3 Germicidal Effectiveness 5.0 UV-C 254 nm 5.1 UV 254 nm Wavelength Properties 5.2 Safety Considerations 5.3 Germicidal Effectiveness...
  • Page 7: Executive Summary

    222 nm and 254 nm for sanitation purposes in industrial and commercial sites. Larson Electronics is a manufacturer of industrial lighting systems, explosion proof devices and power distribution products. The company has more than 40 years of experience in the industrial sector, serving a wide range of organizations and businesses.
  • Page 8: Uv Light Sanitation

    fungi and other deadly microbes. Moreover, far-UV light is considered to be eye and skin safe for humans, as 222 nm UV rays cannot penetrate the skin to levels that cause burns or severe damage. A 2018 study published in the US National Library of Medicine National Institutes of Health has proven that chronic irradiation with 222 nm far-UV lamps does not cause epidermal lesions often associated with exposure to traditional 254 nm UV-C rays.
  • Page 9: Far Uv-C 222 Nm

    During sanitation, UV-C light in large, concentrated doses causes RNA and DNA mutations in microbes during absorption. The ideal wavelength for peak absorptivity occurs at wavelengths of 254nm to 262nm (for traditional UV sanitation) and 222 nm. According to a 2012 study published in US National Library of Medicine National Institutes of Health, UV-C treatment has the following devastating effects on microbes: “The light-induced damage to the DNA and RNA of a microorganism often results from the...
  • Page 10: Safety Considerations

    higher UV absorption than conventional 254 nm. The possibility of photo-reactivation is also decreased due to the high energy of 222 nm. Spectral-selective excimer lamps are the artificial light source of choice when generating far-UV 222 nm light for sanitation. The term “excimer” is short for excited dimer, which refers to the presence of dimeric molecules with nanosecond-lifespans in an excited state.
  • Page 11: Germicidal Effectiveness

    period to mice. In both tests (skin samples and chronic exposure), traditional UV sanitation lights in the 254 nm range were tested using the same types of samples for comparison. After exposure to 222 nm light, the skin samples in the first test did not produce lesions or display signs of irritation, as well as did not generate damaging levels of cyclobutane pyrimidine dimers (CPD) and pyrimidine-pyrimidone 6-4 photoproducts (6-4PP).
  • Page 12: Uv-C 254 Nm

    type A2 biosafety cabinet housed the chamber with the samples. The results showed that the 222 nm light eliminated more than 95 percent of the aerosolized H1N1 influenza virus. A 2020 study (pre-print; under review) aimed to determine the effectiveness of far-UV 222 nm light on human coronaviruses from subgroups alpha (HCoV-229E) and beta (HCoV-OC43).
  • Page 13: Safety Considerations

    manufactured using doped fused quartz (can produce 185 nm ozone) or soda-lime glass (cannot produce 185 nm ozone) so that UV 254 nm bands from the mercury arc can pass through the material. Quartz-based UV-C lights increase electrical efficiency and require a short warm-up time of 30 seconds to reach full output.
  • Page 14: Conclusion

    from the study concluded that such devices, which include systems used to administer UV-C light or radiation, can improve survival rate of individuals. At the front lines, UV-C light is proven to be effective in sanitizing N95 filtering facepiece respirators (N95 FFRs). Medical staff must deal with the shortage in N95 respirators and other protective devices by disinfecting the equipment and reusing them.
  • Page 15: References

    administered in occupied or busy areas without protective equipment. Safety gear in the form of bio-hazard suits, coats, safety glasses, visors, gloves, barriers and curtains must be used at all times when using traditional 254 nm lamps to prevent exposure. 7.0 References Fact Sheet on UV Disinfection for COVID-19;...

Table of Contents