LK 422 Manifold Shunt Tmax
 
Technical Data
Max. operating pressure
Max. pressure differential
in operation
Operational temperature
secondary
Operational temperature
primary
Ambient temperature
Circulation pump
Voltage
Output
Current
Cable protection class
Relative humidity
Control valve
Material
Media
Approved pump
DESIGN
LK Manifold Shunt Tmax is used in systems with a main pump. The
shunt unit can be mounted directly to LK Manifold RF from the left
or right. The shunt unit is fi tted as standard with a constant
thermostat controlled feed temperature as well as an automatic
speed controlled pump for reduced energy consumption and quieter
operation. The guideline capacity of this shunt unit is
a maximum of 130 m2 fl oor heating surface. The
capacity is dependent on heat requirement, laying
procedure etc.
1. Supply pipe to the floor heating circuit
Male thread 1"
2. Thermometer
Accessory (not included), immersion thermometers 0-80°C.
3. Supply pipe from primary circuit
Ball valve with a 3/4" female thread.
4. Check valve
Built-in check valve cartridge.
5. Return pipe to the primary circuit
1.0 MPa
0.1 Mpa
+12 - +65 ºC
Max. +80 ºC
Max. +70 ºC
Grundfos UPM3 Auto 15-70
with cast iron pump housing
1 phase 230V AC, -15 %/
+10 %, 50 Hz, PE
Max. 52 W
Max. 0.52 A
IP44
Max. 95%
Kvs 4,1
Nickel-plated brass MS58,
stainless acid-proof steel
Water, water/glycol 50/50%,
water/ethanol 70/30%
CE, EC Low Voltage
Directive (2006/95/ EC)
incl. additions
www.lkarmatur.com
Connection to the primary circuit's 3/4" female thread.
6. Control & isolation valve
Control & isolation valve to the primary circuit 8 mm hexagonal
socket.
7. Return pipe from the floor heating circuit
Male thread 1".
8. Bracket
Accessory (not included).
9. VF Valve
Valve for adjustment and control of the primary flow, also used as
isolation valve. 8 mm hexagonal socket.
10. Thermostat for temperature control (TEMP)
Thermostat for controlling feed temperature.
11. Circulation pump
Circulation pump, Grundfos UPM3 Auto 15-70 with automatic speed
control.
1
11
9
8
7
6
5
10
4
3
2
1

Advertisement

loading

Summary of Contents for LK Armatur Tmax 422

  • Page 1 LK 422 Manifold Shunt Tmax   Technical Data Connection to the primary circuit’s 3/4” female thread. Max. operating pressure 1.0 MPa 6. Control & isolation valve Max. pressure differential Control & isolation valve to the primary circuit 8 mm hexagonal socket.
  • Page 2: Circulation Pump

    ENG | Instruction Manual Monteringsanvisning | LK Fördelarshunt VS2 REQUIREMENTS CIRCULATION PUMP LK 422 Manifold Shunt 2.0 should be used in systems with a primary The circulation pump has automatic speed control, which reduces supply temperature that is weather dependent. Check the settings power consumption and gives a quieter operation as the pump ad- of the temperature limiter control.
  • Page 3: Dimensions Drawing

    ENG | Instruction Manual FLOW CONTROL VALVE SETTING FOR TEMPERATURE LIMITER (TEMP) Return flow primary circuit The temperature limiter can be set between 22 - 65 °C. The The estimated primary flow can be adjusted using the shunt unit’s factory setting is about 50 °C. Always check the setting at return valve, as shown in the table below.
  • Page 4: Technische Daten

    DE | Bedienungsanleitung LK 422 Manifold Shunt Tmax   6. Regelventil & Sperren des Primärrücklaufs TECHNISCHE DATEN Regelventil zum Einstellen des Primärdurchflusses. Wird auch als Absperrventil verwendet. Innensechskant 8 mm. Max. Betriebsdruck 1,0 MPa Maximaler Differenzdruck in Betrieb. 0,1 MPa 7.
  • Page 5 DE | Bedienungsanleitung Monteringsanvisning | LK Fördelarshunt VS2 VORAUSSETZUNGEN UMWÄLZPUMPE Die Umwälzpumpe besitzt eine automatische Drehzahlregelung, die den Die LK 422 Verteilerregelstation 2.0 muss in ein System mit außen- Energieverbrauch und das Betriebsgeräusch der Pumpen verringert, da temperaturkompensierter primärer Vorlauftemperatur eingebaut die Pumpe den Durchfluss je nach den Anforderungen der Anlage an- werden.
  • Page 6 Primary side CC III System mit Hauptpumpe. with main pump CC II CC I Q (l/min) SE.33.C.184.161228 LK Systems AB, Box 66, 161 26 Bromma | www.lksystems.se 5 (10) LK ARMATUR AB www.lkarmatur.se www.lkarmatur.com LK ARMATUR DEUTSCHLAND GMBH www.lkarmatur.de www.lkarmatur.de...