Vermason 222635 Application, Operation And Maintenance Manual

Advertisement

EUROPE
Analogue Surface Resistance Test Kit
Operation and Maintenance
Figure 1. Vermason
222635
Resistance Test Kit

Description

The Vermason Analogue Surface Resistance Test Kit
is a portable battery-powered instrument designed to
measure resistance point-to-point (Rp-p) and surface to
ground (Rg). The meter is equipped with an automatic
test voltage selector. The test voltage will switch from
10 V to 100 V should the measured resistance exceed
1 x 10
ohms.
5
ESD protected area products should be tested:
A. Prior to installation to qualify for listing in user's ESD
control plan. Approved ESD materials (see product
qualification table at EN 61340-5-1 Table 3 EPA
requirements).
B. During initial installation.
C. For periodic checks of installed products as part of
EN 61340-5-1 Compliance Verification testing per
EN 61340-2-3.
TB-7572 Page 1 of 3
July 2018
TECHNICAL BULLETIN TB-7572
Analogue Surface
DESCO EUROPE - 2A DUNHAMS LANE, LETCHWORTH, HERTFORDSHIRE, SG6 1BE, UK
Phone: +44 (0) 1462 672005 • E-mail: Service@DescoEurope.com, Website:
Compliance Verification Plan
"A compliance verification plan shall be established to
ensure the organization's fulfilment of the requirements
of the plan. Process monitoring (measurements) shall be
conducted in accordance with a compliance verification
plan that identifies the technical requirements to be
verified, the measurement limits and the frequency at
which those verifications shall occur. The compliance
verification plan shall document the test methods
used for process monitoring and measurements. If the
organization uses different test methods to replace
those of this standard, the organization shall be able
to show that the results achieved correlate with the
referenced standards. Where test methods are devised
for testing items not covered in this standard, these shall
be adequately documented including corresponding
test limits. Compliance verification records shall be
established and maintained to provide evidence of
conformity to the technical requirements. The test
equipment selected shall be capable of making the
measurements defined in the compliance verification
plan." (EN 61340-5-1 clause 5.2.4)
The Analogue Surface Resistance Meter and its
accessories are available as the following item numbers:
Item
Description
222635
Analogue Surface Resistance Test Kit (Test
Leads and Electrodes Included)
222637
Analogue Surface Resistance Meter
222636
Shielded Test Leads
222634
Electrodes, 2.27 kg

Packaging

222635
Analogue Surface Resistance Test Kit
1
Analogue Surface Resistance Meter
1
9 V Alkaline Battery
2
Shielded Test Leads
2
2.27 kilograms Electrodes
1
Plastic Carrying Case
1 Certificate of Calibration
222637
Analogue Surface Resistance Meter
1
Analogue Surface Resistance Meter
1
9 V Alkaline Battery
1 Certificate of Calibration
DescoEurope.com
Made in the
United States of America
© 2018 DESCO INDUSTRIES INC
Employee Owned

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 222635 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vermason 222635

  • Page 1 (EN 61340-5-1 clause 5.2.4) Description The Analogue Surface Resistance Meter and its The Vermason Analogue Surface Resistance Test Kit accessories are available as the following item numbers: is a portable battery-powered instrument designed to measure resistance point-to-point (Rp-p) and surface to...
  • Page 2 Features and Components 6. Perform additional measurements by placing the electrode on the most commonly used or worn areas. CAUTION: If there is a current limiting resistor in the worksurface and the worksurface resistance is lower, the measurement will primarily be the resistance of the resistor.
  • Page 3 resistance range through the entire garment. Alternately, the garment while worn can be tested using a wrist strap tester.” (ESD Handbook ESD TR20.20-2008 section 5.3.13.3.1.7 Periodic Verification Testing) 25 cm Maintenance The area surrounding the cable jacks at the top end of the meter should be wiped with a clean cloth moistened with alcohol to remove skin oils that will accumulate and affect the accuracy at high resistances.

This manual is also suitable for:

222637222636222634

Table of Contents