Zodiac Pool Systems Nature2 Fusion Soft 700 Installation Instructions

Electrolytic cell assembly replacement kit
Hide thumbs Also See for Nature2 Fusion Soft 700:

Advertisement

Quick Links

Installation Instructions
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local
requirements exist. In the event no such state or local requirement exists, the maintainer must be a professional
with sufficient experience in pool equipment installation and maintenance so that all of the instructions in
this manual can be followed exactly. Before installing this product, read and follow all warning notices and
instructions that accompany this product. Failure to follow warning notices and instructions may result in
property damage, personal injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury,
property damage, or death.
These instructions are to be used with the following Zodiac Replacement Kits:
R0502800 -- Nature
R0503000 -- Nature
This document gives instructions for installing the
Nature
Fusion Electrolytic Cell Assembly.
2
For technical assistance, please contact our Technical
Support Department at (800) 822-7933. All of the
instructions must be followed exactly. Read through
these instructions completely before starting the
procedure.
WARNING
Do not operate electrolytic cell without proper flow or
water circulation. A buildup of flammable gases would
result in hazardous conditions which could lead to fire
or explosion.
To reduce the risk of electric shock, fire or injury,
service should only be attempted by a qualified Pool
Service Professional.
When using electrical products, basic precautions
should always be followed, including the following:
• DANGER: RISK OF ELECTRIC SHOCK WHICH
CAN RESULT IN SERIOUS INJURY OR DEATH.
Before attempting installation or service, ensure that
all power to the device is disconnected/turned off at
the circuit breaker.
• Grounding is required. The unit should be installed
by a qualified service representative and should be
properly grounded.
• Install to permit access for servicing.
• Before attempting any electrical wiring, be
sure to read and follow Safety Instructions
in the Installation and Operation Manual.
Wiring should only be attempted by a qualified
professional.
Nature
Cell Assembly Replacement Kit
Fusion Soft 700 Electrolytic Cell Assembly Replacement Kit
2
Fusion Soft 1400 Electrolytic Cell Assembly Replacement Kit
2
Fusion Soft Electrolytic
WARNING
To avoid personal injury when working with pool
chemicals, always wear rubber gloves and eye
protection, cover exposed skin, and work in a well
ventilated area. Use caution when choosing a
location to open and use chemicals as they may
damage any surface into which they come in contact.
If any chemical gets on your skin, rinse the area
immediately with water. If any chemical gets on your
clothing, immediately remove the piece of clothing
and rinse with water.
1.
Electrolytic Cell Replacement
1.
Unplug the DC cord from electrolytic cell. See
Figure 1.
Always turn pump off prior to installing or removing
any components from the pool's plumbing. Your
pump/filter system is operated under pressure and
pressure must be released before you begin to avoid
system damage or personal injury. Open the air relief
valve on your pool filter to release the pressure in the
system.
2.
Run the pool pump and filter for five (5) minutes.
After this time turn off the pool pump.
WARNING
WARNING

Advertisement

loading

Summary of Contents for Zodiac Pool Systems Nature2 Fusion Soft 700

  • Page 1 Installation Instructions Nature Fusion Soft Electrolytic 2® Cell Assembly Replacement Kit WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist.
  • Page 2 Figure 1. Installation of the Electrolytic Cell DESCRIPTION Assembly Electrolytic Cell Assembly O-Ring, Large Collar Instructions ZODIAC POOL SYSTEMS, INC. 6000 Condor Drive • Moorpark, CA • 93021 Tel: 800-822-7933 • Fax: 877-327-1403 © 2010 Zodiac Pool Systems, Inc. 1003...

This manual is also suitable for:

Nature2 fusion soft 1400R0502800R0503000