Infinera XTM Series Technical Description

Infinera XTM Series Technical Description

400g otn flexponder
Hide thumbs Also See for XTM Series:

Advertisement

XTM Series
400G OTN Flexponder
Technical Description
FXP400GOTN
Rev C | 2018-04-16

Advertisement

Table of Contents
loading

Summary of Contents for Infinera XTM Series

  • Page 1 XTM Series 400G OTN Flexponder Technical Description FXP400GOTN Rev C | 2018-04-16...
  • Page 2 © Copyright 2018 Infinera Corporation. All rights reserved. This Manual is the property of Infinera Corporation and is confidential. No part of this Manual may be reproduced for any purposes or transmitted in any form to any third party without the express written consent of Infinera.
  • Page 3 Technical Assistance Customer Support for Infinera products is available, 24 hours a day, 7 days a week (24x7). For information or assistance with Infinera products, please contact the Infinera Technical Assistance Center (TAC) using any of the methods listed below: •...
  • Page 4: Table Of Contents

    5.13.1 Auto Alarm Enable Function ................12 5.13.2 PM Alarms Suppression Function ..............12 6 Consequent Actions ......................13 6.1 Client defects ......................13 6.2 Line defects......................14 7 Mechanical Layout ......................15 8 Technical Data ........................16 TD_FXP400GOTN Rev C | 2018-04-16 Infinera Proprietary and Confidential...
  • Page 5: Introduction

    Document Revision History Table 1 Document Revision History Revision Date Description of changes 2017-09-21 1st release. 2017-10-11 Minor editorial change 2017-12-22 Updated with R30 features 2018-04-16 Update on R30.1 features TD_FXP400GOTN Rev C | 2018-04-16 1 (17) Infinera Proprietary and Confidential...
  • Page 6: General

    NE’s. As a result, client equipment of different types (e.g. SDH/SONET, IP routers) and from different vendors can be connected to the XTM Series network without any impact on the transmission path through the network.
  • Page 7: Cfp2 Based 400G Otn Flexponder

    LEXPONDER CFP2 based 400G OTN Flexponder The FXP400GOTN is a 1-slot unit in the XTM Series that can transport up to 4x100Gbps client service capacity on two line ports. Depending on configuration and choice of line modules the unit can work either as a dual transponder for 100Gbps services to a 100Gbps coherent line or a dual muxponder for 2x100Gbps services to a 200G coherent line, or a mix between the two.
  • Page 8: Chassis Support

    The TM-3000 and TM-301 has an upper power limit for the card cage, for TM-3000 depending on the type of DC filters used. Please see the Technical Description of each chassis for power figures and limitations. TD_FXP400GOTN Rev C | 2018-04-16 4 (17) Infinera Proprietary and Confidential...
  • Page 9: Application Examples

    ROADM infrastructure with full tunability of the line frequency over the 80 channels in the XTM Series. Thus a total of 80 x 200Gbps capacity can be deployed over the same fiber pair using 16QAM line modulation. The CFP2’s supports automatic electrical Chro- matic Dispersion Compensation, thus removing the need for external dispersion compensators.
  • Page 10: Interoperability

    FXP400GOTN as a separate software script package to allow upgrades of already installed field units of the OCM/2P. Once upgraded, the OCM/2P will be able to recognize both 10G as well as 100G and 200G services of the XTM Series. Please see the Technical Description of the OCM/2P for more information.
  • Page 11: Basic Functionality

    ODUJ2. Thus a 100GbE client will be mapped to an ODU4 container using GMP map- ping process and then multiplexed to a ODUJ2 to construct a 200G frame with OTN capable framing structure. The output is an OTUJ2 frame with additional SD-FEC. TD_FXP400GOTN Rev C | 2018-04-16 7 (17) Infinera Proprietary and Confidential...
  • Page 12: Forward Error Correction

    • Up to 96, 15-minute reports • Up to 40, 24-hour reports These reports are located in the node and can be uploaded to Infinera DNA-M or other higher layer management systems. Each counter can be assigned a threshold in order to raise an alarm if exceeded.
  • Page 13: Line Pm (End To End)

    LIM-100G. The GCC0 for OTUJ2 is updated in release R30.0 to support full speed 13Mbps from the pre- vious 2.6Mbps. Special consideration is necessary when upgrading from previous releases. TD_FXP400GOTN Rev C | 2018-04-16 9 (17) Infinera Proprietary and Confidential...
  • Page 14: Synchronization

    • Board temperature: Given in Centigrade. • Received optical power level. • Laser Bias current. • Laser output power. All optical parameters are based on existing functionality within the pluggable modules. TD_FXP400GOTN Rev C | 2018-04-16 10 (17) Infinera Proprietary and Confidential...
  • Page 15: Board Data

    UNCTIONALITY 5.12 Board data All boards/units within a XTM Series Network Element have unit related information stored in non-volatile memory banks. This information is stored at production and is required for admin- istration and start-up of the boards. The information is divided into three main groups: •...
  • Page 16: Alarms

    Any generated alarms are collected by the Control Unit and accessible via the node manager ENM or network manager Infinera DNA-M. The status LED (STS-LED) on the board front indi- cates the severity of the active alarms. See 7 Mechanical Layout.
  • Page 17: Consequent Actions

    End-to-end PM counters will reflect defects inserted in the OTN domain. Client defects Fig. 8 Consequent actions for client defects. Note that Forward ALS is an option for 100GbE-LAN (not displayed here) TD_FXP400GOTN Rev C | 2018-04-16 13 (17) Infinera Proprietary and Confidential...
  • Page 18: Line Defects

    Fig. 9 Consequent actions for line defects on OTU4. Note that Forward ALS is an option for 100GbE-LAN (not dis- played here) Fig. 10 Consequent actions for line defects on OTUJ2. Note that forward ALS is an option for 100GbE-LAN (not dis- played here) TD_FXP400GOTN Rev C | 2018-04-16 14 (17) Infinera Proprietary and Confidential...
  • Page 19: Mechanical Layout

    ECHANICAL AYOUT Mechanical Layout Fig. 11 Mechanical layout FXP400GOTN TD_FXP400GOTN Rev C | 2018-04-16 15 (17) Infinera Proprietary and Confidential...
  • Page 20: Technical Data

    “L” indicates that the TRX is used on line side. “C” indicates that the TRX is used on client side. * The TOM-100G-Q-LR4 support is restricted to versions labeled 130-0333-002 For technical data on supported transceivers, see Dimensioning Guidelines within the System Manual. TD_FXP400GOTN Rev C | 2018-04-16 16 (17) Infinera Proprietary and Confidential...
  • Page 21 0dBm Wavelength switching time 60 s Transmitter cold startup time 90 s Table 7 Product Revision Data Product number Introduced Release Comment FXP400GOTN R29.1 (September 2017) 1st released version. TD_FXP400GOTN Rev C | 2018-04-16 17 (17) Infinera Proprietary and Confidential...

This manual is also suitable for:

Fxp400gotn

Table of Contents