Confidence and control.
INSTRUCTION MANUAL
CHEST FREEZER
3735262-NR, 3735301-NR, 3735302-NR, 3735303-NR, 3735304-NR,
3735305-NR, 3735306-NR, 3735307-NR, 3735308-NR, 3735309-NR,
3735310-NR, 3735312-NR, 3736203-NR, 3736204-NR

Advertisement

Table of Contents
loading

Summary of Contents for Bromic Heating 3735262-NR

  • Page 1 Confidence and control. INSTRUCTION MANUAL CHEST FREEZER 3735262-NR, 3735301-NR, 3735302-NR, 3735303-NR, 3735304-NR, 3735305-NR, 3735306-NR, 3735307-NR, 3735308-NR, 3735309-NR, 3735310-NR, 3735312-NR, 3736203-NR, 3736204-NR...
  • Page 3: Table Of Contents

    CONTENTS 1. PREFIX 2. IMPORTANT NOTES & WARNINGS 3. PRODUCT OVERVIEW 4. INSTALLATION 5. OPERATION 6. PRODUCT LOADING AND STORAGE 7. MAINTENANCE 8. TROUBLESHOOTING 9. ENVIRONMENTAL & DISPOSAL NOTES 10. WARRANTY Note: Bromic Refrigeration reserves the right to make changes to specifications, parts, components and equipment without prior notification. This Installation, operation and service manual may not be reproduced in any form with prior written consent from Bromic Refrigeration.
  • Page 4: Prefix

    1. PREFIX This manual contains important information about the installation, operation, and maintenance of Bromic chest freezers. Please pay close attention to the important safety information shown throughout this instruction manual. Any safety information will be accompanied by the following safety alert symbols: DANGER, WARNING, IMPORTANT...
  • Page 5: Important Notes & Warnings

    2. IMPORTANT NOTES AND WARNINGS • Read all instructions before installing or using this appliance. • Retain this manual for future reference. • Use this appliance only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury.
  • Page 6 Warning: Risk of fire / Flammable materials • WARNING: The refrigerant used in this appliance is flammable, use caution during handling, servicing and disposal of the appliance. • WARNING: Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
  • Page 7: Product Overview

    3. PRODUCT OVERVIEW GD0007S-NR CF0200ATCG-NR CF0300ATCG-NR CF0400ATCG-NR Part Number 3735262-NR 3735301-NR 3735302-NR 3735303-NR Height, mm 1296 External Dimension Width, mm 1298 1010 1298 Depth, mm Capacity Litres Gross Weight Temp. Range Degree Celsius -22 to -12°C -22 to -12°C -22 to -12°C -22 to -12°C...
  • Page 8 CF0500ATCG-NR CF0600ATCG-NR CF0200FTFG-NR CF0300FTFG-NR Part Number 3736203-NR 3736204-NR 3735308-NR 3735309-NR Height, mm External Dimension Width, mm 1548 1750 1010 Depth, mm Capacity Litres Gross Weight Temp. Range Degree Celsius -22 to -12°C -22 to -12°C -22 to -12°C -22 to -12°C Climate Class* Class Max Ambient...
  • Page 9 CF0400FTFG-NR CF0500FTFG-NR CF0700FTFG-NR CF0300FTSS-NR Part Number 3735310-NR 3735304-NR 3735305-NR 3735312-NR Height, mm External Dimension Width, mm 1298 1548 2055 1012 Depth, mm Capacity Litres Gross Weight Temp. Range Degree Celsius -22 to -12°C -22 to -12°C -22 to -12°C -25 to -15°C Climate Class* Class Max Ambient...
  • Page 10 CF0500FTSS-NR CF0700FTSS-NR Part Number 3735307-NR 3735306-NR Height, mm External Dimension Width, mm 1552 2055 Depth, mm Capacity Litres Gross Weight Temp. Range Degree Celsius -25 to -15°C -25 to -15°C Climate Class* Class Max Ambient Temperature Lid Type Type Hinged Hinged Lid Shape Type...
  • Page 11: Installation

    4. INSTALLATION Locating the Cabinet Ensure the following instructions are observed as this is vital for proper and trouble-free operation. • Do not install the cabinet outdoors. • Locate the appliance in a dry and well ventilated place. • The unit must be positioned on a level surface. •...
  • Page 12: Operation

    Power Supply • The appliance must not be plugged into a multiple outlet power board. • The appliance is supplied with a flexible power cord fitted with a 3-pin plug. • The socket used must be properly earthed and fuse/RCD protected. •...
  • Page 13 Using the controller • For solid lid models (as per below picture), adjust the thermostat using the dial below to set the appliance’s internal temperature, moving clock-wise to achieve lower internal temperature. You should only make small adjustment and wait 24 hours to see whether further adjustment is required.
  • Page 14: Product Loading And Storage

    6. PRODUCT LOADING AND STORAGE IMPORTANT: Run the refrigerator for at least 24 hours before loading. WARNING: WARNING: Do not store explosive substances such as aerosol cans with a flammable propellant inside the appliance. Start-up • Clean the interior surface with a soft cloth and warm water before loading. •...
  • Page 15: Troubleshooting

    4. Remove all frozen food and store them temporarily in another freezer or insulated container. 5. Remove all baskets, leave the lid fully open, the defrost is now in progress until there is no ice left inside the appliance. You can use the included ice scraper to remove the ice. 6.
  • Page 16: Environmental & Disposal Notes

    9. ENVIRONMENTAL AND DISPOSAL NOTES These refrigerated cabinets are designed to high standards of environmental protection and recycling convenience. Cyclopentane, an environmentally friendly foaming agent, has been used. Cyclopentane is distinguished by zero ozone depletion potential (ODP) and zero global warming potential (GWP). The refrigerant used and contained within a hermetically tight circuit is environmentally friendly and does not contain chlorine and zero ODP.
  • Page 17: Warranty

    10. WARRANTY All Bromic products are manufactured to the highest quality standard and are supported by our Extra Care Service Warranty, including guarantees against any material or workmanship defects; guarantees that cannot be excluded under Australian Consumer Law. Warranty Terms vary across the range. Please ensure you are familiar with the Terms and Conditions that apply to the purchase of your Bromic product by referring to the Warranty Policy included with your purchased product.
  • Page 18 SERVICE REQUEST PRIORITY PRIORITY SERVICE When the unit is performing its primary function such as cooling or heating, or presents an OH&S or food safety risk PRIORITY SERVICE When the unit is performing its primary function, and presents no OH&S or food safety risk. i.e. lights, gaskets. locks, door adjustment SERVICE CALL PLACED BEFORE...
  • Page 20 BROMIC REFRIGERATION 10 Phiney Place, Ingleburn (Sydney) NSW 2565 Australia T. 1300 276 642 For further product information bromicrefrigeration.com.au bromicrefrigeration.com.au 1300 276 642...

Table of Contents