Output Subsystem; Outp; Outp:prot:cle; Outp:prot:del - Agilent Technologies 664xA Programming Manual

Gpib dc power supplies
Hide thumbs Also See for 664xA:
Table of Contents

Advertisement

Output Subsystem

This subsystem controls the power supply's voltage and current outputs and an optional output relay.
Do not install or program the Agilent Relay Accessories if the power supply maximum output current
rating (see Table 3-1) exceeds the contact ratings of the relay.

OUTP

This command enables or disables the power supply output. The state of a disabled output is a condition of zero output
voltage and a model-dependent minimum source current (see Table 3-1). The query form returns the output state.
Commandd Syntax
Returned Parameters
Related Commands

OUTP:PROT:CLE

OUTP:PROT:DEL

OUTP:PROT:CLE
OUTP:PROT:DEL
Returned Parameters
OUTPut[:STATe] <bool>
Parameters
0 | OFF | 1 | ON
Suffix
(None)
*RST Value
0
OUTP 1
Examples
Query Syntax
OUTPut(:STATe]?
<NR1> 0 or 1
*RST *RCL *SAV
Clears any OV (overvoltage), OC (overcurrent, unless set via external voltage control),OT
(overtemperature), or RI (remote inhibit) protection features. After this command, the output is
restored to the state it was in before the protection feature occurred.
Sets the time between the programming of an output change that produces a CV, CC, or
UNREG condition and the recording of that condition by the Status Operation Condition
register. The delay prevents the momentary changes in power supply status that can occur
during reprogramming from being registered as events by the status subsystem. Since the delay
applies to CC status, it also delays the OCP (overcurrent protection) feature. The OVP
(overvoltage protection) feature is not affected by this delay.
Examples
OUTP:PROT:CLE
OUTPUT:PROTECTION:DELAY 75E-1
OUTP:PROT:DEL MIN
Query Syntax
OUTP:PROT:CLE
OUTPut:PROTection:DELay? OUTPut:PROTection:DELay? MIN
OUTPut:PROTection:DELay? MAX
<NR3> OUTP:PROT:DEL? returns value of programmed delay.
OUTP:PROT:DEL? MIN and OUTP:PROT:DEL? MAX return
the minimum and maximum programmable delays.
Related Commands
OUTP:PROT:CLE
OUTP:PROT:DEL
OUTPUT:STATE ON
OUTPUT:PROTECTION:CLEAR
OUTPUT:PROT:DELAY MAX
(None)
(None)
*RST *RCL *SAV