Mini Power Post™ - USER GUIDE Contents Introduction ................................. 3 Safety Guidelines ..............................3 Included with Post ..............................4 Features ................................. 5 Installation .................................. 6 Installing Post ..............................6, 7 Wiring ..................................7, 8 General Operation ..............................9 Septic Tank Monitoring ............................9 Alarm Auxiliary with Auto Dialer ...........................
4. DO NOT use this product with or near flammable liquids. 5. DO NOT install this product in locations classified as hazardous or in explosive atmospheres as defined by any applicable electrical safety code. Alderon Industries™ - Leading Edge Control Products | 3...
Versa’larm™ indoor alarm for liquid level monitoring. (6) Pump Float Switch The pump float switch is used to control the pump directly. When actuated the pump float switch will pass power to the pump. 4 | Alderon Industries™ - Leading Edge Control Products...
(7) QR Code (not shown) - Scan code on bottom enclosure cover which directs you to alderonind.com where additional information can (4) Partition - Separates high voltage from low voltage. be found for the Mini Power Post™. Alderon Industries™ - Leading Edge Control Products | 5...
Take the 3-hole rubber grommet (#4) which has slits next to the holes and insert cables, then insert the rubber grommet into the conduit. 5. Place the PVC coupler over the end of the conduit. 6 | Alderon Industries™ - Leading Edge Control Products...
STEP 2: INSTALLING WIRE INTO WAGO CONNECTOR 1) Lift tab(s) upward. 2) Insert wire(s) into slot. 3) Press tab(s) downward. TO OPEN TO CLOSE 4) Make sure wire(s) are secured. WAGO WAGO Alderon Industries™ - Leading Edge Control Products | 7...
Page 8
STEP 4: BACKFILL Once all steps of the installation and wiring are complete, take the dirt/soil removed and backfill the area you dug for the post and riser. Backfill Area Backfill Area 8 | Alderon Industries™ - Leading Edge Control Products...
Page 9
When the alarm float switch is deactivated, the indoor alarm should reset for the next alarm cycle. STEP 3: ADDITIONAL TESTING Make sure to follow all individual instructions for the indoor alarm, pump float switch, alarm float switch, or accessories for any additional testing. Alderon Industries™ - Leading Edge Control Products | 9...
Versa’larm™ in the house provides a local audible and visual alarm indication in a convenient indoor location. Mini Power Post™ Versa’larm™ Indoor Alarm 5:05 House to Septic REGENERATION Alarm Septic to Drain Field MENU ENTER Float Pump Switch 10 | Alderon Industries™ - Leading Edge Control Products...
Mini Power Post™ Versa’larm™ Indoor Alarm 5:05 House to Septic REGENERATION Alarm Septic to Drain Field MENU ENTER Float Auto Dialer Pump Switch Alderon Industries™ - Leading Edge Control Products | 11...
Three-Year Limited Warranty - Standard Products LIMITED WARRANTY: Subject to the conditions of this Three-Year Limited Warranty, Alderon Industries, LLC (“Alderon”) war- rants to the original user or consumer of an Alderon product (the “Product”) that, for a period of three (3) years from the date of manufacture, the Product will be free from defects in materials and workmanship under normal use and service, and provided the Product is installed, operated and maintained in accordance with instructions supplied by Alderon.
Page 14
Mini Power Post™ - USER GUIDE This page intentionally left blank 14 | Alderon Industries™ - Leading Edge Control Products...
Page 15
Mini Power Post™ - USER GUIDE This page intentionally left blank Alderon Industries™ - Leading Edge Control Products | 15...
Page 16
UG00009_Rev06_PRPT-00003_Mini Power Post | May 27, 2022 11:31 AM Company Location: 151 16th Street South, Hawley, MN 56549 Mailing Address: PO Box 827, Hawley, MN 56549 Main Office Phone: 218.483.3034 Website: alderonind.com General Inquiry Email: info@alderonind.com Submit New Orders: orders@alderonind.com...
Need help?
Do you have a question about the Mini Power Post PRPT-00003 and is the answer not in the manual?
Questions and answers