BEFORE INSTALLATION, PLEASE READ
THESE INSTRUCTIONS FIRST.
Congratulations on the purchase of your new Nanolux DE FIXTURE 1000W
luminaire. We have done everything to ensure a long life and safe operation
of your new product, but the installation and use of the ballast is at the
responsibility of the user. Incorrect use or installation can lead to failure and
damage to the ballast. Damage to the luminaire and electronic circuitry as a
result of incorrect installation or use revokes your warranty. Read this manual
carefully before installing your luminaire.
TECHNICAL SPECIFICATIONS
Model
1000W
Input Voltage
AC480V
Output Voltage
200V-300V
Input Frequency
50/60Hz
Output Power
MAX 1100W
Power Factor
≥0.97
Crest Factor
≤1.7
THD
≤10%
Dimming
NCCS-0-10V
Strike Lamp
Double Ended Lamp
Output Frequency
100KHz-200KHz
Over Temperature Protection; Under Voltage Protection;
Protection
Function
Open/Short Circuit Protection;
590*240*242 mm
Size
23.2*9.4*9.5 inch
(L*W*H)
5.2 kgs
Weight
11.5 lbs
INSTALLATION
COMPLY WITH LOCAL INSTALLATION REGULATIONS
These luminaires are suitable for damp indoor locations. Do not install your
luminaires in a wet environment or outdoors.
Do not operate these luminaires close to combustible materials. The lamp
and reflector will get hot during operation. Do not touch the reflector or
lamp during or right after operation. Make sure the power cord does not
touch any hot part of the luminaire. Make sure the lamp is clean and inserted
correctly.
A normal operating environment temperature should be below 35°C (95°F).
Exceeding the maximum environmental temperature will stress electronic
components, which will lead to shorter lifetime and decreased reliability.
NCCS-0-10V DIMMING
This model is compatible with NCCS-0-10V protocol control.
Insert telephone wire into the jack of the NCCS-0-10V protocol control, and
then Dimming function on the luminaire will be enabled.
● Maximum of 120 ballasts can be controlled.
● Simulate sunrise and sunset for dimming.
● Turn off the device automatically with time and temperature setting.
In & Out jacks included on the ballast allows for multifixtures connected in
parallel.
CAUTION:
After installation, verify installation was a success by cycling the lights on/off
a few times, by setting 'over temperature shut down' to a low value like 85°F,
and rubbing the temperature probe with your fingers, tricking the
NCCS-0-10V protocol control into an over temperature condition and
shutting the lights off. Then leave the probe alone, and after recommended
10-15 minutes NCCS-0-10V protocol control should turn all the lights back
on.
For detailed instructions, please refer to NCCS-0-10V protocol control
operating manual.
LAMP REPLACEMENT AND HOT
RESTRIKE
C A U T I O N :
• Always install the lamp before connecting your luminaire to mains.
• Allow lamp to cool 30 minutes before restarting (hot restrike).
• When changing the lamp always disconnect the luminaire from mains by
removing the mains plug. Let the lamp and reflector cool down for 30
minutes before changing as they are very hot. When replacing a defect
lamp without disconnecting mains the lamp will not start. Disconnecting
the power will restart the ballast.
• DO NOT touch hot Ceramic socket.
• Make sure the DE lamp wires are correctly within the sockets copper wire
clamps.
• Make sure to fully close the ceramic socket to the correct position and keep
the socket clean to provide proper function.
• Fragile !! Be careful and do not exert excessive force while moving the
ceramic slider on the ceramic socket connection.
• Keep away from water.
TO TAKE OUT A LAMP:
• DISCONNECT THE MAINS FIRST
• Open the lamp holders by sliding them outward. The lamp is held by a
metal spring at each side. It is recommended to hold the lamp while
opening the lamp holders to prevent the lamp from falling.
TO INSTALL A NEW LAMP:
• DISCONNECT FROM MAINS FIRST
• Make sure the lamp is clean, wear cotton gloves and clean the lamp after
installation with a dry soft cloth. Never use detergents to clean a lamp, use
pure alcohol or wipe clean with a dry clean soft cloth.
• Make sure the end wires are straight.
• Open the lamp holders by sliding them outward. Press the lamp in the
fitting until the metal springs hold the lamp, with the glass vacuum seal
pointed downward.
• Close the lamp holders by sliding them inward.
• Wipe the lamp with a clean soft cloth.
• Be sure not to touch the reflective material of the reflector with your bare
hands.
NOTICE: Reflectors are made from a high grade pure aluminum, which will
oxidize and degrade over time. This results in lower reflectivity and reduced
efficiency, and over 10% light loss at the canopy. It is recommended that you
mark the installation date on the outside of reflector with a permanent
marker, and replace reflectors once a year.
SUITABLE LAMPS
The Nanolux Double Ended 1000W luminaires are designed and tested to
drive HPS & MH Electronic lamps. Using Single Ended 1000W HPS & MH
Electronic lamps can cause damage to your ballast and lamp.
REFLECTOR REPLACEMENT
The Nanolux DE fixture should be handled with care. If it is damaged or
deformed you should replace it. We recommend to change the reflector
every year for optimal results. Replacement reflectors are available through
your Nanolux Technology reseller.
To replace the reflector, you must remove the lamp first as described above
in how to install the lamp. Let the reflector cool down if it has been operating
to prevent an injury. At the end of the reflector bracket, you will find a
chrome knob. Pull the knob outward to release the pin holding the reflector
in place (a-1). The reflector can then be pulled away from the ballast end of
the bracket to remove it from the two pins holding it in place (a-2 & a-3).
When inserting the new reflector, slide it into the two pins (a-2 & a-3) and
then release the pin (a-1) to secure it in place.