FIXTURE HANGING
Fixture hanging equipment included with unit for necessary mounting.
1. Attach the steel wire hanger to fixture.
2. Hang the fixture in the desired location.
Optional commercial hanging bracket installation.
1. Remove the two screws from both sides of the top cover.
2. Install two hanging brackets.
3. Confirm the hanging brackets are installed on the fixture properly and are not loose.
4. Hang the fixture in the desired location.
SCOPE OF USE AND MAINTENANCE
● Comply with local installation regulations.
● Only compatible with Nanolux DE HPS/MH 600W/1000W,CMH 1000W/630W
lamp preventing damage to the lamp and your ballast.
● Store the fixture in a dry and clean environment, with an ambient temperature of
-10 ~ 40 °C and ambient humidity of less than 90% RH. It is recommended to store
it no more than (6) months. If it is expired (6) months, please have an experiment
on it to insure the secure operation.
● Please keep products safe. Avoid mechanical pressure, excessive vibration and
dropping the unit during the process of assembly to protect the reflector and lamp.
● Keep away from water, oil and organic solvent, or it will decrease the reflectivity and
have the potential risk of electric leakage.
● All equipment, devices and machines shall be effectively grounded.
● Do not touch hot ceramic socket.
● Disconnect the mains first if you need to clean the lamp with wet cloth.
Check your electrical connection regularly.
● Opening the luminaire will void warranty.
TROUBLESHOOTING
Symptom
Cause
Corrective Action
Incorrect Lamp
Make sure lamp knob is set to proper setting for your lamp.
Knob Selection
Incorrect Dimming
Make sure dimming knob is not set to NCCS-RTU/
Knob Selection
NCCS-0-10V if you are not using that function.
Incorrect Lamp
Verify that bulb is installed correctly, and the electrical
Installation
contacts in ceramic bulb holder are not damaged.
Replace lamp with a known working lamp. Refer to
Lamp does
Faulty Lamp
"Lamp Replacement and Hot Restrike" section.
not turn on.
Use voltmeter to confirm incoming voltage is within
AC90V-280V, or plug ballast into a different socket that
Faulty Power Input
you know is working.
Incorrect Controller
Make sure controller is programmed to turn the lights on.
Programming
Remove NCCS-RTU/NCCS-0-10V control, set dimming
Faulty Control Input
knob to 100%, and see if that solves problem. If so, the
error is with the control, not the ballast.
Incorrect Lamp
Make sure lamp knob is set to proper setting for your lamp.
Knob Selection
Replace lamp with a known working lamp. Refer to
Lamp turns
Faulty Lamp
"Lamp Replacement and Hot Restrike" section.
on, but
shuts off.
Remove NCCS-RTU/NCCS-0-10V control, set dimming
Faulty Control Input
knob to 100%, and see if that solves problem. If so, the
error is with the control, not the ballast.
Incorrect Lamp
Lamp tries
Make sure lamp knob is set to proper setting for your lamp.
Knob Selection
to strike but
never fully
Replace lamp with a known working lamp. Refer to
Faulty Lamp
comes on.
"Lamp Replacement and Hot Restrike" section.
WARRANTY
Nanolux Technology warrants the mechanical and electronic components of this
product to be free of defects in material and workmanship if used under normal
operating conditions for a period of three (3) years from the original date of
purchase. If the product shows any defects within this period and that defect is
not due to user error or improper use, Nanolux Technology shall, at its discretion,
either replace or repair the product using suitably new or refurbished parts. For
Nanolux lamp and reflector the warranty period is one (1) year from the original
date of purchase. In case Nanolux decides to replace the entire product, this
limited warranty shall apply to the replacement ballast for the remaining initial
warranty period, i.e. three (3) years from the date of purchase of the original
product. For service return the ballast to your shop with the original sales
receipt.
For more information about Nanolux product please visit nanoluxtech.com
PATENTED PRODUCTS, COUNTERFEITING NOT ALLOWED.
Designed by NANOLUX in California
Made in China
OPERATING
MANUAL
BALLAST
DE-CHILL 1000-SUMMIT
DOUBLE ENDED FIXTURE
NCCS-RTU/0-10V COMPATIBLE
w w w . n a n o l u x t e c h . c o m
Illuminating Your Grow

Advertisement

loading

Summary of Contents for NANOLUX SUMMIT 1000W

  • Page 1 If the product shows any defects within this period and that defect is not due to user error or improper use, Nanolux Technology shall, at its discretion, either replace or repair the product using suitably new or refurbished parts. For Nanolux lamp and reflector the warranty period is one (1) year from the original date of purchase.
  • Page 2 • Always install the lamp before connecting your luminaire to power supply. • Allow lamp to cool 10 minutes before restarting (hot restrike). The Nanolux DE-CHILL SUMMIT fixture should be handled with care. If it is damaged • When changing the lamp always disconnect the luminaire from power supply by or deformed you should replace it.