Page 2
A copy of this limited warranty can also be obtained by written request to Federal Signal Corporation, 2645 Federal Signal Drive, University Park, IL 60484, email to info@fedsig.com or call +1 708-534-3400.
Activating the sirens may not result in people taking the desired actions if those to be warned are not properly trained about the meaning of siren sounds. Siren users should follow FEMA recommendations and instruct those to be warned of the correct actions to be taken. Model 2001TRBP and 2001TRBP Kit Federal Signal www.fedsig.com...
Page 5
Safety Messages • After installation, service, or maintenance, test the siren system to confirm that it is operating properly. Test the system regularly to confirm that it will be operational in an emergency. • If future service and operating personnel do not have these instructions to refer to, the siren system may not provide the intended audible warning, and service person- nel may be exposed to death, permanent hearing loss, or other bodily injuries.
Page 6
NOTICE is used to address practices not related to physical injury. Read and understand the information contained in this manual before attempting to deploy or service the siren. Pay careful attention to notices located on the equipment. Model 2001TRBP and 2001TRBP Kit Federal Signal www.fedsig.com...
The 2001TRBP consists of an aluminum encased transformer with a mounting bracket. The 2001TRBP can be used as the only source of power for mechanical sirens (AC operation). The 2001TRBP transformer operates from 208, 220, or 240 Vac. The transformer output is 46 Vdc at 130 A and 115 Vac at 10 A.
Specifications Features The 2001TRBP transformer rectifier has the following features. • High-powered transformer rectifier for powering mechanical sirens from nominal 220 Vac (2001TRBP) • Provides primary system power (46 Vdc) for DC sirens • Provides 115 Vac for a siren controller, chargers, and heaters •...
7011A069-08 Brass washer 70700520 2 position buss bar 8402109A Buss bar rt angle 8402138A NOTE: The 2001TRBP Kit is for installations that already have an existing transformer. Table 6 2001TRBP Contents 2001TRBP 2001TRBP Service Description includes Part Number Transformer rectifier...
Mount the transformer assembly as close as possible to the control unit to keep cabling distances as short as possible. See Figure 1 and Table 4 for the size and weight of the 2001TRBP transformer. Mount the 2001TRBP to a structure that can support the transformer.
Troubleshooting Figure 3 Transformer Rectifier Wiring to Control Cabinet F1F2 10 10 2001TRBP 291254G Troubleshooting NOTE: It is normal for the 46 Vdc output of the transformer to have 20-30 V of AC ripple without load. With load, the AC ripple significantly decreases.
If you are experiencing any difficulties, contact Federal Signal Customer Care at 800-548-7229 or 708-534-3400 extension 7511 or Technical Support at 800-524-3021 or 708-534-3400 extension 7329 or e-mail at techsupport@fedsig.com. For instruction manuals and information on related products, visit http://www.fedsig.com. Model 2001TRBP and 2001TRBP Kit Federal Signal www.fedsig.com...