Data center distribution panel digital power meter/single-phase three feeder power measuring module, actually makes possible data center energy management (152 pages)
Page 5
Always power the device with the correct rated voltage. ◼ Install the device in a suitable electrical cabinet by following recommended installation instructions. ◼ Failure to take these precautions could cause serious injuries or death. ⓒ 2011 Rootech Inc. All Rights Reserved Page 5...
Page 6
300 V. About the Manual Rootech Inc. reserves the right to make changes in the product specifications shown in this User Guide without prior notice. We recommend that customers should obtain the latest information on product specifications and the manual before making orders.
Page 7
Rootech will decide at its discretion whether to repair or replace it or give a refund for the product for when the warranty period for the product expired or issues related to the product are not applicable for warranty terms and conditions.
Page 8
Warranty Accura 2300S/2350 User Guide Rootech shall not be liable for any other claims except the claims made by customers, including the original purchaser, his employees, agents, or contractors for any loss, damage, or expense incurred related to the purchased product when the above warranty terms and conditions are not fulfilled.
Page 9
Accura 2300S/2350 User Guide Revision History Revision History The following versions of 「Accura 2300S/2350 User Guide」 have been released. Revision Date Description Revision 2.00 February 16, 2022 Release of the User Guide for the device with the HW revision number higher than 200.00...
Step 5: Connecting Accura 2300S with Accura 2350 ........................98 Step 6: Connecting Accura 2300S Devices for External Communication ................100 Ethernet Communication ..................................100 RS-485 Communication ..................................102 Step 7: Accura 2300S Control Power Supply and Ground Wiring ...................104 Control Power Supply Wiring ................................104 Ground Wiring ......................................104 Page 10...
Page 11
Setup Mode.......................................124 Accura 2350-1PSCSH ......................................133 Applied Model ......................................133 Front View ........................................133 Display Mode ......................................134 Setup Mode.......................................134 Chapter 4 Accura 2300S Operation/Setup ......................... 145 Device Configuration ......................................145 Operation Mode .....................................145 LED Display ........................................145 Button Operation ....................................146 Display Mode ........................................148 Front View ........................................148 Selecting the ID of Accura 2350 Module...........................150...
Page 12
No Event Log ......................................209 Necessary Steps for Device Setup ................................210 Step 1: Setup for the Voltage Wiring of Accura 2300S and PT Rating ..............210 Step 2: Automatic Assignment of Accura 2350 Module IDs and Update of IDs ..........211 Step 3: Ethernet Setup of Accura 2300S ............................214 Chapter 5 Measurements ...............................
Page 13
IEC 62053-24:2020 Static Meters for Fundamental Reactive Energy (Classes 0.5S, 1S, 1, 2 and 3) ....250 Appendix C Accuracy/Reliability ........................... 251 Accuracy ........................................251 Reliability ........................................252 Appendix D Line-to-neutral Voltage for Common Main Supply Systems ..............253 Wiring Modes ......................................253 Appendix E Ordering Information ..........................254 ⓒ 2011 Rootech Inc. All Rights Reserved Page 13...
Page 14
Fig 2.25 Accura 2350-1PSCSH Module Dimensions ....................... 45 Fig 2.25 Installation Diagram of Accura 2300S/2350-3P/1P Power Measuring Modules ........47 Fig 2.26 Installation Diagram of Accura 2300S/2350 Split-core Power Measuring Modules ......48 Fig 2.28 Mounting Accura 2300S on the Panel ........................49 Fig 2.28 Mounting Accura 2350-3P Module on the Panel ....................
Page 15
Fig 2.53 Single-phase 2-wire, Direct Connection ........................83 Fig 2.54 Single-phase 2-wire Connection with 1 PT ......................83 Fig 2.55 Digital Input/Output Channels on Accura 2300S ....................84 Fig 2.56 Digital Input ....................................85 Fig 2.57 Application of DC Relay ..............................86 Fig 2.58 Application of AC Relay ..............................
Page 16
Fig 2.70 Connecting the Cable for Connection with the ZCT with the External ZCT ........... 96 Fig 2.71 Connecting Accura 2350 Module to the External ZCT ..................97 Fig 2.68 Example of Connecting Accura 2300S to Accura 2350 for Dedicated Communication ....98 Fig 2.69 Ethernet Communication Ports on Accura 2300S ....................100 Fig 2.70 Connecting Accura 2300S Devices via Ethernet Communication ...............101...
Page 17
Fig 5.10 Demand Calculation ................................229 Fig 5.11 Predicted Demand Calculation .............................229 Fig 5.12 Hourly Auto Sync .................................230 Fig 5.13 Manual Sync ...................................230 Fig 5.14 Symmetrical Components..............................233 Fig 5.15 Aggregation Process ................................234 ⓒ 2011 Rootech Inc. All Rights Reserved Page 17...
Power Meters Specialized for Managing Major Branch Loads The distribution panel digital power meter product line includes Accura 2300S installed on the front of distribution panels(including MCC panels) and Accura 2350 installed at individual branch loads inside distribution panels.
Page 19
Maximum/Minimum/Average Values Available within an Aggregation Interval Accura 2300S/2350 calculate the average of the data collected every 0.5 seconds based on the data measured over one cycle for various parameters, including voltage, current, and power. Based on this data, it also provides the maximum/minimum/average values for various aggregation intervals, including 1 second, 5 seconds, 1 minute, 5 minutes, 1 hour and 6 hours.
Split-core Structure Enabling Device Installation on Live Wires (Applicable for Split-core Modules) Accura 2350-3PSC/1PSC/1PSCSH modules feature the split-core structure. It allows for the easy installation of the products on live wires without the need to cut off power. Page 20 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2300S/2350 User Guide Chapter 1 Introduction Fig 1.3 Installation of Accura 2350-3PSC/1PSC Module ⓒ 2011 Rootech Inc. All Rights Reserved Page 21...
Accura 2300S/2350 User Guide Applications Enterprise-wide Energy Management Accura 2300S/2350 provide energy data on individual branch loads in distribution panels. Therefore, it allows for a true enterprise-wide energy management in conjunction with other Accura products (Accura 3300S/3500S/3550S/3700/7500) installed in switchgear panels.
Product Information Distribution Panel Digital Meter/Power Measuring Module Distribution panel digital power meter product line includes Accura 2300S mounted on the front of distribution panels, and Accura 2350 modules mounted on the load side of branch circuits (or the main incoming feeder) inside the panel.
Page 24
However, in 3P3W mode you can perform three-phase measurements by installing two Accura 2350-1PSCSH modules for A and C phases. 6. LB: Long Busbar 7. It is the weight excluding the mounting wings. Page 24 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2350-TEMPS Measures the internal and external temperature of the panel(based on the installation location) DO(Digital Output) Accura 2350-DO Provides digital outputs which can be controlled from Accura 2300S and also remotely IDC(DC Current Input) Accura 2350-IDC Measures analog DC current inputs (-20 mA to 20 mA) VDC(DC Voltage Input)
Accura 2300S/2350 User Guide Installation Example Accura 2300S/2350 Power Measuring Modules The following figure shows an example of the installation method frequently used in distribution panels. Fig 1.4 Installation Example of Accura 2300S/2350 Modules Installation Front panel Accura 2300S Distribution panel digital power meter...
Accura 2300S/2350 User Guide Chapter 1 Introduction Accura 2300S/2350-3PSC/1PSC/1PSCSH Split-core Power Measuring Modules Accura 2350-3PSC/1PSC/1PSCSH modules feature the split-core structure. Thus, it allows for the easy installation of the products on live wires without the need to cut off power. The following figure shows an example of installing split-core power measuring modules in distribution panels.
Page 28
- When you measure current above 250 A - When it is difficult to make through-hole connections with the 3P/1P power measuring modules because of a large gap between busbars(or cables). Page 28 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2300S/2350 User Guide Chapter 1 Introduction Product Features Accura 2300S Distribution Panel Digital Power Meter Accura 2300S collects data from multiple Accura 2350 modules connected with the 6C telephone line and displays data on its LCD screen. Accura 2300S Function...
Page 30
Accura 2300S with special-purpose modules except for the Accura 2350-3P/1P modules, refer to the individual manual for each module. 8. It indicates the maximum length of the 6C telephone line used to connect Accura 2300S to all Accura 2350 modules with each port(RJ12-1 or RJ12-2) on Accura 2300S.
Page 31
4. The data are unavailable on the LCD screen of Accura 2300S and are only available via communication. ⓒ 2011 Rootech Inc. All Rights Reserved Page 31...
Page 32
4, 7 Internal Communication with Accura 2300S Dedicated Receives the sampled voltage data from Accura 2300S communication Sends measurement and operational status data to Accura 2300S Control Power Supply Power voltage Receives power from Accura 2300S Page 32...
Page 33
The value can be set to the rated current(default) or peak demand current(only available via communication). 4. The data are unavailable on the LCD screen of Accura 2300S and are only available via communication. ∑ ( ...
Accura 2300S/2350 User Guide Chapter 2 Installation Installation Conditions Accura 2300S/2350 should be mounted in a dry, dirt-free location away from heat sources and very high electric fields. To operate the products properly, the following environmental conditions should be considered.
Accura 2300S/2350 User Guide Chapter 2 Installation Before Installation Before installing Accura 2300S/2350, observe the following instructions and safety precautions. Caution You should power up the device after voltage and current wiring is completed. Product Appearance Fig 2.1 Accura 2300S Front Fig 2.2 Accura 2300S Side...
Three-phase power measuring module Single-phase power measuring module Fig 2.5 Accura 2350-3PSC/1PSC/1PSCSH Split-core Power Measuring Modules Split-core three-phase power measuring module Split-core single-phase power measuring module Split-core single-phase single-hole power measuring module Page 36 ⓒ 2011 Rootech Inc. All Rights Reserved...
6C telephone line: 10 cm x 1 PCB for overcurrent protection Cable for connection with the ZCT 1. It is provided when you select the ZCT connection option when ordering the product. ⓒ 2011 Rootech Inc. All Rights Reserved Page 37...
6C telephone line: 20cm x 1, 10cm x 1 PCH for overcurrent protection Cable for connection with the ZCT 1. It is provided when you select the ZCT connection option when ordering the product. Page 38 ⓒ 2011 Rootech Inc. All Rights Reserved...
Cable for connection with the ZCT 1. It is provided when you select the ZCT connection option when ordering the product. Fig 2.13 TM-3P Components TM-3P Two screws Fig 2.14 TM-1P Components TM-1P One screw ⓒ 2011 Rootech Inc. All Rights Reserved Page 39...
Fig 2.20 Accura 2350-1P Module Dimensions Accura 2350-1P-250A-105 Accura 2350-1P-125A-60 Accura 2350-1P-100A/60A-50 Accura 2350-1P-50A/30A-35 1. Accura 2350-1P-250A-105 is a single-phase model, so middle through hole is not used. Fig 2.22 Accura 2350-1PSH Module Dimensions Accura 2350-1PSH-50A/30A-35 Page 42 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2350-3PSC-125A-90 Accura 2350-3PSC-60A-75 Accura 2350-3PSC-CT5A-90 1. The middle hole of the module(B phase) is little larger than other two holes(A and C phases) in consideration of installing two external CTs. Page 44 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2350-1PSC-60A-50 1. Accura 2350-1PSC-250A-105 is a single-phase model, so the through-hole in the middle of the module is not used. Fig 2.25 Accura 2350-1PSCSH Module Dimensions Accura 2350-1PSCSH-800A Accura 2350-1PSCSH-630A/400A ⓒ 2011 Rootech Inc. All Rights Reserved Page 45...
Page 46
Accura 2350-1PSCSH-400A 63.0 52.5 x 115.0 mm 1. If the rated current exceeds 250 A, you should use Accura 2350-3P-CT5A-75 or Accura 2350-3PSC-CT5A-90 module with external CTs(the secondary current rating: 5 A). Page 46 ⓒ 2011 Rootech Inc. All Rights Reserved...
Installation Diagram Accura 2300S/2350-3P/1P Power Measuring Modules The following figure shows an example of the installation method frequently used in distribution panels. Fig 2.25 Installation Diagram of Accura 2300S/2350-3P/1P Power Measuring Modules Use transformer for more than AC 265 V...
The modules’ split-core structure allows you to easily install them on live wires without needing to cut off power. The following figure shows an example of installing split-core modules in distribution panels. Fig 2.26 Installation Diagram of Accura 2300S/2350 Split-core Power Measuring Modules [3-phase 3-wire]...
Step 1: Installing the Product Mounting Accura 2300S on the Panel Accura 2300S is mounted on the front of the distribution panel(or panelboard). ① Fit the meter into the panel cutout. (ANSI 4” and DIN96 cutout supported) ② Attach the connector to the side of the meter.
⑥ Combine the MCCB with the busbar of the three-phase terminal block by tightening the screws. Fig 2.28 Mounting Accura 2350-3P Module on the Panel 0.5 mm clearance between devices required Page 50 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2300S/2350 User Guide Chapter 2 Installation Fig 2.29 Mounting Accura 2350-3P Module on the Panel through Mounting Holes Applied Model Accura 2350-3P-250A- TM-3P-105 Applied Model Accura 2350-3P-250A- TM-3P-105-LB ⓒ 2011 Rootech Inc. All Rights Reserved Page 51...
Page 52
Chapter 2 Installation Accura 2300S/2350 User Guide Applied Model Accura 2350-3P-125A-90 TM-3P-90 Applied Model Accura 2350-3P-125A-90 TM-3P-90-LB Page 52 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 53
Accura 2300S/2350 User Guide Chapter 2 Installation Applied Model Accura 2350-3P-100A-75 TM-3P-75L Applied Model Accura 2350-3P-60A-75 TM-3P-75 ⓒ 2011 Rootech Inc. All Rights Reserved Page 53...
Page 54
Chapter 2 Installation Accura 2300S/2350 User Guide Applied Model Accura 2350-3P-100A-75 Accura 2350-3P-60A-75 TM-3P-75-LB Applied Model Accura 2350-3P-100A-75 Accura 2350-3P-60A-75 TM-3P-75L-LB Page 54 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2300S/2350 User Guide Chapter 2 Installation Fig 2.30 Mounting the Mounting Plate / Terminal Block for Accura 2350-3P on the Panel Accura 2350-3P-250A-105 TM-3P-105 Accura 2350-3P-125A-90 TM-3P-90 Accura 2350-3P-100A-75 TM-3P-75L ⓒ 2011 Rootech Inc. All Rights Reserved Page 55...
Page 56
Chapter 2 Installation Accura 2300S/2350 User Guide Accura 2350-3P-60A/CT5A-75 TM-3P-75 Page 56 ⓒ 2011 Rootech Inc. All Rights Reserved...
⑥ Combine the MCCB with the busbar of the single-phase terminal block by tightening the screws. Fig 2.31 Mounting Accura 2350-1P Module on the Panel(Load Located on the Right Side) 0.5 mm clearance between devices required ⓒ 2011 Rootech Inc. All Rights Reserved Page 57...
Chapter 2 Installation Accura 2300S/2350 User Guide Fig 2.32 Mounting Accura 2350-1P Module on the Panel through Mounting Holes Applied Model Accura 2350-1P-250A- TM-1P-105 Applied Model Accura 2350-1P-125A-60 TM-1P-60 Page 58 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 59
Accura 2300S/2350 User Guide Chapter 2 Installation Applied Model Accura 2350-1P-125A-60 TM-1P-60-LB Applied Model Accura 2350-1P-100A-50 Accura 2350-1P-60A-50 TM-1P-50L ⓒ 2011 Rootech Inc. All Rights Reserved Page 59...
Page 60
Chapter 2 Installation Accura 2300S/2350 User Guide Applied Model Accura 2350-1P-100A-50 Accura 2350-1P-60A-50 TM-1P-50 Applied Model Accura 2350-1P-100A-50 Accura 2350-1P-60A-50 TM-1P-50-LB Page 60 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 61
Accura 2300S/2350 User Guide Chapter 2 Installation Applied Model Accura 2350-1P-100A-50 Accura 2350-1P-60A-50 TM-1P-50L-LB ⓒ 2011 Rootech Inc. All Rights Reserved Page 61...
Chapter 2 Installation Accura 2300S/2350 User Guide Fig 2.33 Mounting the Mounting Plate / Terminal Block for Accura 2350-1P on the Panel Accura 2350-1P-250A-105 TM-1P-105 Accura 2350-1P-125A-60 TM-1P-60 Accura 2350-1P-100A-50 TM-1P-50L Page 62 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 63
Accura 2300S/2350 User Guide Chapter 2 Installation Accura 2350-1P-60A-50 TM-1P-50 Accura 2350-1P-50A-35 Accura 2350-1P-30A-35 Accura 2350-1PSH-50A-35 Accura 2350-1PSH-30A-35 ⓒ 2011 Rootech Inc. All Rights Reserved Page 63...
③ Attach Accura 2350-3PSC power measuring module to the mounting plate by sliding it into the plate. Fig 2.34 Mounting Accura 2350-3PSC Module on the Panel(New Installation) 0.5 mm clearance between devices required Sliding 0.5 mm clearance between devices required Page 64 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2300S/2350 User Guide Chapter 2 Installation Fig 2.35 Mounting Accura 2350-3PSC Module on the Panel through Mounting Holes Applied Model Accura 2350-3PSC-250A-105 Applied Model Accura 2350-3PSC-125A-90 ⓒ 2011 Rootech Inc. All Rights Reserved Page 65...
Page 66
Chapter 2 Installation Accura 2300S/2350 User Guide Applied Model Accura 2350-3PSC-60A-75 Applied Model Accura 2350-3PSC-CT5A-90 Page 66 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2300S/2350 User Guide Chapter 2 Installation Fig 2.36 Mounting the Mounting Plate for Accura 2350-3PSC Module on the Panel Accura 2350-3PSC-250A-105 Accura 2350-3PSC-125A-90 Accura 2350-3PSC-60A-75 ⓒ 2011 Rootech Inc. All Rights Reserved Page 67...
② Secure Accura 2350-3PSC module to the panel with a cable tie(200 x 4.8 mm). Fig 2.37 Mounting Accura 2350-3PSC Module on the Panel (Retrofit Installation) Fixed with 200 x 4.8 mm cable ties Page 68 ⓒ 2011 Rootech Inc. All Rights Reserved...
③ Attach Accura 2350-1PSC power measuring module to the mounting plate by sliding it into the plate. Fig 2.38 Mounting Accura 2350-1PSC Module on the Panel(New Installation) 0.5 mm clearance between devices required Sliding 0.5 mm clearance between devices required ⓒ 2011 Rootech Inc. All Rights Reserved Page 69...
Chapter 2 Installation Accura 2300S/2350 User Guide Fig 2.39 Mounting Accura 2350-1PSC Module on the Panel through Mounting Holes Applied Model Accura 2350-1PSC-250A-105 Applied Model Accura 2350-1PSC-125A-60 Page 70 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 71
Accura 2300S/2350 User Guide Chapter 2 Installation Applied Model Accura 2350-1PSC-60A-50 ⓒ 2011 Rootech Inc. All Rights Reserved Page 71...
Chapter 2 Installation Accura 2300S/2350 User Guide Fig 2.40 Mounting the Mounting Plate for Accura 2350-1PSC Module on the Panel Accura 2350-1PSC-250A-105 Accura 2350-1PSC-125A-60 Accura 2350-1PSC-60A-50 Page 72 ⓒ 2011 Rootech Inc. All Rights Reserved...
② Secure Accura 2350-1PSC module with a cable tie(200 x 4.8 mm). Fig 2.41 Mounting Accura 2350-1PSC Module on the Panel (Retrofit Installation) Fixed with 200 x 4.8 mm cable ties ⓒ 2011 Rootech Inc. All Rights Reserved Page 73...
② Secure the mounting plate by tightening the screws diagonally. ③ Attach Accura 2350-1PSCSH power measuring module to the mounting plate by sliding it into the plate. Fig 2.42 Mounting Accura 2350-1PSCSH Module on the Panel (New Installation) Sliding Page 74 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2300S/2350 User Guide Chapter 2 Installation Fig 2.43 Mounting Accura 2350-1PSCSH Module on the Panel through Mounting Holes Applied Model Accura 2350-1PSCSH-800A Applied Model Accura 2350-1PSCSH-630A Accura 2350-1PSCSH-400A ⓒ 2011 Rootech Inc. All Rights Reserved Page 75...
Chapter 2 Installation Accura 2300S/2350 User Guide Fig 2.44 Mounting the Mounting Plate for Accura 2350-1PSCSH Module on the Panel Accura 2350-1PSCSH-800A Accura 2350-1PSC-630A/400A Page 76 ⓒ 2011 Rootech Inc. All Rights Reserved...
② Secure Accura 2350-1PSCSH to the panel with a cable tie(200 x 4.8 mm). Fig 2.45 Mounting Accura 2350-1PSCSH Module on the Panel (Retrofit Installation) Fixed with 200 x 4.8 mm cable ties ⓒ 2011 Rootech Inc. All Rights Reserved Page 77...
Chapter 2 Installation Accura 2300S/2350 User Guide Step 2: Wiring Accura 2300S Voltage Wiring of Accura 2300S Fig 2.46 Voltage Wiring of Accura 2300S Voltage Input Item Description Connector name Connector type Terminal block Wire specifications 2.1 – 3.5 mm (14 –...
Page 79
Caution Failure to observe the following instructions may result in severe injury or death. During normal operation of Accura 2300S, hazardous voltages are present on its terminal strips that ◼ connect the PT(Potential Transformer), voltage input, power, and external I/O circuits. The secondary of the PT may generate fatal voltages/currents resulting from the primary of the PT.
Select 「1P3U(1P3W)」 via 「METER > Conn(Voltage connection)」 setup menus. Voltages on Line 1 and Line 2 should be connected to the V and V ports, and the Ground line should be connected to the port. Page 82 ⓒ 2011 Rootech Inc. All Rights Reserved...
Select 「1P2U(1P2W)」 via 「METER > Conn(Voltage connection)」 setup menus. The voltage on Line 1 should be connected to the V port, and the Ground line should be connected to the V port. ⓒ 2011 Rootech Inc. All Rights Reserved Page 83...
Chapter 2 Installation Accura 2300S/2350 User Guide Digital Input/Output Wiring of Accura 2300S Fig 2.55 Digital Input/Output Channels on Accura 2300S 2 Digital Input Channels Channel 1 Channel 2 Port name Ground 1. Ground DI is the common terminal for both channels.
Additional commands issued within the pulse period are counted and the counted number of pulses occur after the end of the pulse period. ⓒ 2011 Rootech Inc. All Rights Reserved Page 85...
4. It applies when the output polarity is normal. If the output polarity is reversed, the closed and open contacts operate reversely. Note For selection of latch or pulse type, refer to 「Chapter 4 Accura 2300S Operation/Setup > Setup Mode > Digital Input/Output Setup > Digital Output Type」 setup menus. Fig 2.57 Application of DC Relay Fig 2.58 Application of AC Relay...
±1 % may occur according to the position of the hole through which cables pass. 4. The middle hole of the module(B phase) is little larger than other two holes(A and C phases) in consideration of installing two external CTs. ⓒ 2011 Rootech Inc. All Rights Reserved Page 87...
Three-phase Module Accura 2350-3P-CT5A-75 Accura 2350-3PSC-CT5A-90 1. If the rated current exceeds 250 A, you should use Accura 2350-3P-CT5A-75 or Accura 2350-3PSC-CT5A-90 module with external CTs(the secondary current rating: 5 A). Page 88 ⓒ 2011 Rootech Inc. All Rights Reserved...
The phase sequence in which the current passes through the cable can be set to A→B→C or C→B→A. Refer to 「Chapter 3 Accura 2350 Operation/Setup > Accura 2350-3P/3PSC > Setup Mode > Phase Sequence/Load Direction Setup」 for details. ⓒ 2011 Rootech Inc. All Rights Reserved Page 89...
Page 90
Direction Setup」 and 「 Phase Setup」 in 「Chapter 3 Accura 2350 Operation/Setup > Accura 2350- 3P/3PSC > Setup Mode」 for details. The phase of each feeder can be set to only line-to-neutral. Page 90 ⓒ 2011 Rootech Inc. All Rights Reserved...
If current is flowing in the primary winding of a CT, opening the CT secondary can cause serious accidents resulting from high voltages. ⓒ 2011 Rootech Inc. All Rights Reserved Page 91...
If current is flowing in the primary winding of a CT, opening the CT secondary can cause serious accidents resulting from high voltages. ⓒ 2011 Rootech Inc. All Rights Reserved Page 93...
PCB for overcurrent protection Note If the external ZCT is connected to the earth ground, the black cable for connection with the ZCT should be connected to the grounded ZCT terminal. Page 96 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2300S/2350 User Guide Chapter 2 Installation Fig 2.71 Connecting Accura 2350 Module to the External ZCT ⓒ 2011 Rootech Inc. All Rights Reserved Page 97...
Accura 2300S/2350 User Guide Step 5: Connecting Accura 2300S with Accura 2350 Accura 2300S collects data from all Accura 2350 modules connected with the 6C telephone line for internal communication and displays the collected data on its LCD screen. Fig 2.68 Example of Connecting Accura 2300S to Accura 2350 for Dedicated Communication...
Page 99
2300S. For details about how to connect Accura 2300S to special-purpose modules, refer to the individual user manuals of special-purpose modules. 4. It indicates the maximum length of the 6C telephone line used to connect Accura 2300S to all Accura 2350 modules with each port(RJ12-1 or RJ12-2) on Accura 2300S.
Ethernet switch that allows two Ethernet ports to be daisy-chained to multiple Accura 2300S meters without the need for a separate external switch. Up to 20 Accura 2300S meters can be connected in a daisy-chain, star, and ring topology. Modbus TCP, the standard protocol is supported for transmission of measurement data.
This can have a serious impact on Ethernet communication quality. Therefore, you should use STP(Shielded Twisted Pair) or SFTP(Screened Failed Twisted Pair) cables. Refer to 「Chapter 4 Accura 2300S Operation/Setup > Setup Mode > Ethernet Communication Setup」 for Ethernet setup.
Chapter 2 Installation Accura 2300S/2350 User Guide RS-485 Communication Accura 2300S supports one RS-485 communication port. Fig 2.71 RS-485 Communication Port on Accura 2300S 1 RS-485 Port Item Description Port name Ta(TRX+), Tb(TRX-), G(Ground) Connector type Screw-type terminal(pluggable) Protocol Modbus RTU Wire specifications 0.21 –...
Accura 2300S/2350 User Guide Chapter 2 Installation Fig 2.72 Connecting Accura 2300S Devices via RS-485 Communication ⓒ 2011 Rootech Inc. All Rights Reserved Page 103...
(14 – 12 AWG), copper or aluminum Rated temperature of the wire Above 70 ˚C Note The ground terminal of Accura 2300S is connected to the earth ground of the panel. Page 104 ⓒ 2011 Rootech Inc. All Rights Reserved...
Function Display mode Displays module IDs and measured values(current, power, energy, etc.) automatically. By setting up the display mode of Accura 2300S device, users can make specific measured values appear on the screens of all Accura 2350 modules. Setup mode Setup of module ID, phase sequence/load direction, and so on.
ID of the module that enables communication Conflict ID Duplicate IDs There are more than 2 identical IDs. communication unavailable Standby ID ID 255 Module ID for checking connection status, communication unavailable Page 106 ⓒ 2011 Rootech Inc. All Rights Reserved...
When 「oFF」 is selected on the leakage current setup screen, the leakage current value is not measured and this screen is also not displayed. ⓒ 2011 Rootech Inc. All Rights Reserved Page 107...
Page 108
When 「oFF」 is selected on the leakage current setup screen, the leakage current value is not measured, and this screen is also not displayed. Page 108 ⓒ 2011 Rootech Inc. All Rights Reserved...
If there is no button operation for 10 seconds in the setup mode, the screen automatically returns to the display mode. If there is no button operation for 25 seconds when changing setup values, the screen automatically returns to the display mode ⓒ 2011 Rootech Inc. All Rights Reserved Page 109...
Page 110
If there is no button operation for 10 seconds in the setup mode, the screen automatically returns to the display mode. If there is no button operation for 25 seconds when changing setup values, the screen automatically returns to the display mode. Page 110 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 111
SET button, but you can automatically assign IDs to all Accura 2350 modules connected to Accura 2300S in the setup mode of Accura 2300S. For more details, refer to 「Chapter 4 Accura 2300S Operation/Setup > Setup Mode > Accura 2350 Module ID Setup >...
Page 113
Only the load direction can be set. The number 1 displayed on the screen means the first hole through which the cable passes, and 3 means the third hole through which the cable passes. Item Description Load direction: → → → → (default) Load direction: ⓒ 2011 Rootech Inc. All Rights Reserved Page 113...
Page 114
Accura 2300S/2350 User Guide Load Wiring Setup When the voltage wiring mode of Accura 2300S is 3P3W or 3P4W and Accura 2350-3P power measuring modules are used, measurements per phase can be performed by selecting the number of loads. If the wiring mode is set to 「3Ld」, 3-phase measurements of current and power are performed.
Page 115
Chapter 3 Accura 2350 Operation/Setup Single load connected between the line and the neutral (Individual current/power calculations for one load) thC: through-hole Connection Single-phase 2 feeders 1P.2 (2 feeders) (Individual current/power calculations on two feeders) ⓒ 2011 Rootech Inc. All Rights Reserved Page 115...
Page 116
.c (measurements for 2 loads connected between A and C phases) a. .b (measurements for 2 loads connected between A and B phases) b. .c (measurements for 2 loads connected between B and C phases) Page 116 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 117
C and A lines) a n (measurements for 1 load connected between the A phase and the neutral) b n (measurements for 1 load connected between the B phase and the neutral) ⓒ 2011 Rootech Inc. All Rights Reserved Page 117...
Page 118
(3) Load Wiring: 1P.2 thC: through-hole Connection 1P.2 (2 feeders) Item 1: first hole (feeder 1) an (A → N, default) 3: third hole (feeder 2) bn (B → N, default) Page 118 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 119
CT ratio setup(1-999) screen is displayed as 1, indicating that the number in the thousands place is 1. 2. d → decimal number ⓒ 2011 Rootech Inc. All Rights Reserved Page 119...
Page 120
LCD screen 0: Normal direction 1: Reverse direction 1. Set the display direction of the LCD screen to Reverse when Accura 2350 three-phase power measuring modules are installed in the reverse direction. Page 120 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 121
The threshold value of leakage current can be set through the LCD screen of Accura 2300S or communication. The threshold value set through Accura 2300S is applied equally to all Accura 2350 modules connected to Accura 2300S.
Page 122
You can set leakage current events through Accura 2300S’ LCD screen or communication. Event setup via Accura 2300S is applied equally to all Accura 2350 modules connected to Accura 2300S. If you want to set a different leakage current event for each Accura 2350 module, you should set the event individually through the SET button on Accura 2350 modules.
ID of the module that enables communication Conflict ID Duplicate IDs There are more than 2 identical IDs. communication unavailable Standby ID ID 255 Module ID for checking connection status, communication unavailable ⓒ 2011 Rootech Inc. All Rights Reserved Page 123...
If there is no button operation for 10 seconds in the setup mode, the screen automatically returns to the display mode. If there is no button operation for 25 seconds when changing setup values, the screen automatically returns to the display mode. Page 124 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 125
You can manually assign IDs to Accura 2350 modules with the SET button, but you can automatically assign IDs to all Accura 2350 modules connected to Accura 2300S in the setup mode of Accura 2300S. For more details, refer to 「Chapter 4 Accura 2300S Operation/Setup > Setup Mode > Accura 2350 Module ID Setup >...
Page 127
Chapter 3 Accura 2350 Operation/Setup Phase Sequence Setup The setup items of phase sequence differ depending on wiring/load direction setup. (1) Wiring/Load Direction: → VLN (Load on the Right Side, Line-to-neutral Wiring) Item Description ⓒ 2011 Rootech Inc. All Rights Reserved Page 127...
Page 128
Chapter 3 Accura 2350 Operation/Setup Accura 2300S/2350 User Guide (2) Wiring/Load Direction: → VLL (Load on the Right Side, Line-to-line Wiring) Item Description Page 128 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 129
Accura 2300S/2350 User Guide Chapter 3 Accura 2350 Operation/Setup (3) Wiring/Load Direction: VLN (Load on the Left Side, Line-to-neutral Wiring) Item Description ⓒ 2011 Rootech Inc. All Rights Reserved Page 129...
Page 130
Chapter 3 Accura 2350 Operation/Setup Accura 2300S/2350 User Guide (4) Wiring/Load Direction: VLL (Load on the Left Side, Line-to-line Wiring) Item Description Page 130 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 131
The threshold value of leakage current can also be set through the LCD screen of Accura 2300S or communication. The threshold value set through Accura 2300S is applied equally to all Accura 2350 modules connected to Accura 2300S.
Page 132
You can set leakage current events through Accura 2300S’ LCD screen or communication. Event setup via Accura 2300S is applied equally to all Accura 2350 modules connected to Accura 2300S. If you want to set a different leakage current event for each Accura 2350 module, you should set the event individually through the SET button on Accura 2350 modules.
ID of the module that enables communication Conflict ID Duplicate IDs There are more than 2 identical IDs. communication unavailable Standby ID ID 255 Module ID for checking connection status, communication unavailable ⓒ 2011 Rootech Inc. All Rights Reserved Page 133...
If there is no button operation for 10 seconds in the setup mode, the screen automatically returns to the display mode. If there is no button operation for 25 seconds when changing setup values, the screen automatically returns to the display mode Page 134 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 135
You can manually assign IDs to Accura 2350 modules with the SET button, but you can automatically assign IDs to all Accura 2350 modules connected to Accura 2300S in the setup mode of Accura 2300S. For more details, refer to 「Chapter 4 Accura 2300S Operation/Setup > Setup Mode > Accura 2350 Module ID Setup >...
Page 137
For three-phase measurements, two or three single-phase modules are required, and you should perform device setup for the modules in a group. For device group setup, refer to 「Chapter 4 Accura 2300S Operation/Setup > Setup Mode > Device Group Setup of Accura 2350-1P Modules」.
Page 138
Three-phase measurement can be performed by installing three single-phase modules in the three- phase 3-wire or three-phase 4-wire connection mode and setting a device group. . For device group setup, refer to 「Chapter 4 Accura 2300S Operation/Setup > Setup Mode > Device Group Setup of Accura 2350-1P Modules」.
Page 139
Single-phase measurement between lines can be performed by installing a single-phase module and selecting the line-to-line wiring mode. 2.1) Single-phase Measurement Select the line-to-line wiring mode. Item (Line-to-line Single-phase Single-hole Connection) ⓒ 2011 Rootech Inc. All Rights Reserved Page 139...
Page 140
For three-phase measurement, two or three single-phase modules are required, and you should perform device setup for the modules in a group. For device group setup, refer to 「Chapter 4 Accura 2300S Operation/Setup > Setup Mode > Device Group Setup of Accura 2350-1P Modules」.
Page 141
Three-phase measurement can be performed by installing three single-phase modules in the three- phase 3-wire or three-phase 4-wire connection mode and setting a device group. For device group setup, refer to 「Chapter 4 Accura 2300S Operation/Setup > Setup Mode > Device Group Setup of Accura 2350-1P Module」.
Page 142
Single-phase measurement between lines can be performed by installing a single-phase module and selecting the line-to-line wiring mode. 4.1) Single-phase Measurement Select the line-to-line wiring mode. Item (Line-to-line Single-phase Single-hole Connection) Page 142 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 143
The threshold value of leakage current can also be set through the LCD screen of Accura 2300S or communication. The threshold value set through Accura 2300S is applied equally to all Accura 2350 modules connected to Accura 2300S.
Page 144
You can set leakage current events through Accura 2300S’ LCD screen or communication. Event setup via Accura 2300S is commonly applied to all Accura 2350 modules connected to Accura 2300S. If you want to set a different leakage current event for each Accura 2350 module, you should set the event individually through the SET button on Accura 2350 modules.
The order of columns is displayed differently in the display mode(DISPLAY) and in the setup mode(SETUP). LED Display The 4 LEDs placed at the bottom left of the front panel display the operation states of Accura 2300S. LED Name...
Fig 4.2 Screen in Display Mode In order to set up and check setup items, including the connection mode of Accura 2300S, PTs, events, Ethernet and RS-485 communication, long press the SETUP button and change the display mode to the setup mode.
You can also check the event log by long pressing the EVENT button even when any event does not Event occur. In the event log mode, the segment appearing in the menu bar at the top of the screen lights up. Fig 4.4 Screen in Event Log Mode ⓒ 2011 Rootech Inc. All Rights Reserved Page 147...
1. d → decimal number. The number in the tens place cannot exceed 3. The LCD screen displays the measurement data of the module ID selected among multiple Accura 2350 modules connected to Accura 2300S. 2. The MODULE LED blinks during communication between Accura 2300S and Accura 2350 modules.
Page 149
2. Accura 2350 module’s ID is used as a communication ID when communicating with Accura 2300S. Time Required for a Startup It takes about 1 minute to start Accura 2300S after powering up the device. During the time, measurement values are not displayed on the LCD screen.
Among multiple Accura 2350 modules connected to Accura 2300S, users can select the ID of Accura 2350 module for which measurement values are displayed on the LCD screen of Accura 2300S. If you long press the ENTER button in the display mode, the module ID appearing on the upper left side of the screen blinks at 0.4-second intervals, and the module ID can be changed using the Up(^)/Down(v)
Page 151
Note The module ID blinks in the following cases: ① Blinks at 1.2 second intervals when Accura 2300S cannot properly communicate with Accura 2350 due to - the disconnection of the communication cable(6C telephone line) - the change of the module ID - duplicate IDs ②...
Chapter 4 Accura 2300S Operation/Setup Accura 2300S/2350 User Guide Full Display Screen The following screen displays measurement data on Accura 2300S and the selected Accura 2350 module. 1. When the selected Accura 2350-3P module performs measurements using single-phase two feeders, the measured values of the feeder 1(the first hole) and the feeder 3(the third hole) are displayed on the first and third lines on the screen, respectively.
THD, and the frequency values sequentially. You can see measurement data in the reverse order by pressing the Up(^) arrow button. ⓒ 2011 Rootech Inc. All Rights Reserved Page 153...
You can see measurement data in the reverse order by pressing the Up(^) arrow button. Net energy is the value obtained by subtracting delivered energy from received energy, and the total energy is the sum of received energy and delivered energy. ⓒ 2011 Rootech Inc. All Rights Reserved Page 155...
Down(v) arrow button, you can see the information of the devices connected to the Ethernet port 1 and the Ethernet port 2, including their IP address and Mac address in sequence. You can see information in the reverse order by pressing the Up(^) arrow button. Page 156 ⓒ 2011 Rootech Inc. All Rights Reserved...
Connection Status Status Star Star topology An Ethernet loop including Accura 2300S is not created. Daisy-chain connection In this case as there is no alternative route, if the connected port gets disconnected, it causes network disconnection with an adjacent Accura 2300S device.
You can navigate to the temperature/ date & time screen by pressing the Right(>) arrow button on the Ethernet screen. On this screen, you can check the temperature measured by the built-in temperature sensor located at the back of Accura 2300S, as well as the current date and time. Fig 4.17 Temperature Display Screen Page 158 ⓒ...
If there is no button operation for 10 minutes in the setup mode, the screen automatically returns to the display mode. If there is no button operation for 1 minute when changing set values, the screen automatically returns to the setup mode. ⓒ 2011 Rootech Inc. All Rights Reserved Page 159...
3-Phase 3-wire Open-Delta (3P3O) 1. 「3P3O」 is the setup menu for old Accura 2300S models that do not support the 3P3W connection mode. Thus, even if the connection mode is set to 3P3O, it works in the same way as the 3P3W connection mode.
The Line 1 voltage should be connected to the V port, and the Ground line should be connected to the V port. In case of 1-phase 2-wire connection, line-to-line and line-to-neutral voltage values are the same. Page 162 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 163
= 1* set line-to-neutral voltage value Demand Sub-interval Accura 2300S uses the sliding window method for demand calculation. Demand time[min] = Demand sub-interval time x Number of demand sub-intervals ex) In Korea, the most commonly used demand subinterval is 15 minutes, and the number of demand subintervals is 1.
Page 164
Number of demand sub-intervals Demand Sync Method Accura 2300S supports two methods for synchronizing the starting time of a demand sub-interval: hourly auto sync and manual sync. Hourly auto sync allows the demand sub-interval to automatically start every hour. Manual sync allows users to manually start the demand sub-interval at the time users issue a sync command.
Page 165
Calculation of Total Power Accura 2300S supports two methods for calculation of the total power based on power per phase. One is to calculate the total power based on the vector sum of 3-phase apparent power. And the other is to calculate the total power based on the arithmetic sum of magnitudes of 3-phase apparent power vectors.
Page 166
1,000 and converting them into integer values. Setup Range Description 1 kWh (default) Energy is accumulated in kWh. 1000 Wh Energy is accumulated in Wh. Page 166 ⓒ 2011 Rootech Inc. All Rights Reserved...
* the set line-to-line voltage value ⁄ Line-to-neutral Reference(line-to-neutral) voltage voltage(V = 1* the set line-to-neutral voltage value 1-phase 2-wire Line-to-neutral Line-to-neutral Reference(line-to-neutral) voltage (1P2W) voltage voltage(V = 1* the set Line-to-neutral voltage value ⓒ 2011 Rootech Inc. All Rights Reserved Page 167...
Fig 4.22 Dip Event Setup(3-phase 4-wire) Reference voltage: set to 380 V Line-to-line voltage (converted to the reference voltage: line-to-neutral) Fig 4.23 Dip Event Setup(3-phase 3-wire) Reference voltage: set to 380 V Line-to-line voltage Page 168 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 169
* the set line-to-line voltage value ⁄ Line-to-neutral Reference (line-to-neutral) voltage voltage(V = 1* the set line-to-neutral voltage value 1-phase 2-wire Line-to-neutral Line-to-neutral Reference(line-to-neutral) voltage (1P2W) voltage voltage(V = 1* the set line-to-neutral voltage value ⓒ 2011 Rootech Inc. All Rights Reserved Page 169...
Fig 4.24 Swell Event Setup(3-phase 4-wire) Reference voltage: set to 380 V Line- to-line (converted to the reference voltage: line-to-neutral) Fig 4.25 Swell Event Setup(3-phase 3-wire) Reference voltage: set to 380 V Line- to-line Page 170 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 171
Event detection enabled Temperature Event Temperature measured by the temperature sensor at the rear of Accura 2300S differs depending on the number of Accura 2350 modules connected to Accura 2300S. The measured temperature is different from the actual temperature in the distribution panel, thus caution is required when setting the temperature event.
Page 172
5.0 - 999.0 % (default 100.0 %) Start threshold expressed as a percentage The reference current for the percentage is the rated current of each Accura 2350 module. Commonly applied to all Accura 2350 modules. Page 172 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 173
Exit the edit mode and navigate to the no.SEL previous setup mode. Commonly applied to all Accura 2350 modules. Users can set on or off status on each Accura 2350 module. ⓒ 2011 Rootech Inc. All Rights Reserved Page 173...
Page 174
If it is set to off, the screen immediately switches to the power event setup screen. Setup Range Description oFF (default) Event detection disabled Event detection enabled Commonly applied to all Accura 2350 modules Page 174 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 175
Commonly applied to all Accura 2350 modules In each voltage connection mode, the reference power is determined by the reference voltage as follows. The reference voltage can be set via 「METER > UrEF(Reference Voltage)」 setup menus. ⓒ 2011 Rootech Inc. All Rights Reserved Page 175...
Page 176
Delay time for the power event [s] 0: If it is set to 0, it indicates the delay time for the power event is 0.5 seconds. Commonly applied to all Accura 2350 modules Page 176 ⓒ 2011 Rootech Inc. All Rights Reserved...
Updates module IDs by long pressing the Right(>) arrow button 1. cn(Communication): Accura 2300S communicates with Accura 2350 in real time via the update of module IDs. 2. cF(Conflict): It indicates the number of Accura 2350 modules with duplicate IDs(ID conflicts) or standby ID. These modules cannot communicate with Accura 2300S.
Page 178
1. The standby ID used to detect connection status is assigned to all Accura 2350 modules as the factory default value. 2. If a specific ID is already assigned to a module, it is excluded when performing automatic ID assignment. Page 178 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 179
1. The standby ID used to detect connection status is assigned to all Accura 2350 modules as the factory default value. 2. If a specific ID is already assigned to a module, it is excluded when performing automatic ID assignment. ⓒ 2011 Rootech Inc. All Rights Reserved Page 179...
Page 180
Status where specific IDs are assigned to Accura 2350 Status where the standby IDs are assigned modules 1. The standby ID used to detect connection status is assigned to all Accura 2350 modules as the factory default value. Page 180 ⓒ 2011 Rootech Inc. All Rights Reserved...
3-phase 4-wire/3-phase 3-wire, Through-hole Wiring of 2 Modules a.[d][d] Module ID for A phase (group ID) c.[d][d] Module ID for C phase Refer to page 183. 1. d → decimal number ⓒ 2011 Rootech Inc. All Rights Reserved Page 181...
Page 182
Assign the ID 7 to the module installed on A phase (L1) b.06 Assign the ID 6 to the module installed on B phase (L2) c.05 Assign the ID 5 to the module installed on C phase (L3) Page 182 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 183
A phase ③ a.06 Assigns the ID 6 to the module installed on A phase (L1) c.05 Assigns the ID 5 to the module installed on C phase (L3) ⓒ 2011 Rootech Inc. All Rights Reserved Page 183...
Page 184
Chapter 4 Accura 2300S Operation/Setup Accura 2300S/2350 User Guide Page 184 ⓒ 2011 Rootech Inc. All Rights Reserved...
255.255.000.000 - 255.255.255.252 Subnet mask (default: 255.255.255.000) Gateway Setup Range Description 000.000.000.000 - 255.255.255.255 Gate way (default: 010.010.010.001) Mac Address Setup Range Description [h][h].[h][h] MAC address [h][h].[h][h] [h][h].[h][h] 1. h → hexadecimal number ⓒ 2011 Rootech Inc. All Rights Reserved Page 185...
Page 186
(default: 010.010.010.001) Modbus-TCP Timeout Setup Range Description 5 - 600 (default: 600) Timeout for no request of Modbus- TCP communication [s] RSTP Setup Range Description oFF (default) RSTP disabled RSTP enabled Page 186 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 187
Accura 2300S/2350 User Guide Chapter 4 Accura 2300S Operation/Setup DHCP Setup Range Description oFF (default) DHCP disabled DHCP enabled Storm Control Setup Range Description oFF (default) Storm control disabled Storm control enabled ⓒ 2011 Rootech Inc. All Rights Reserved Page 187...
Description [d][d][d] (default: 0) 0, 1 - 247 In order to read Accura 2300S’ measurement values via RS-485 communication, the device address must be set to a valid value other than 0. 1. d → decimal number Page 188 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 189
(same as Accura 2300’s map) r050 RTM050’s map If the RS-485 communication map is set to r050, it is possible to perform communication with the map used for the RTM050 device. ⓒ 2011 Rootech Inc. All Rights Reserved Page 189...
Resets the maximum/minimum values Peak demand is also reset. Energy Reset Setup Range Description rESEt Resets energy(kWh, kVARh, kVAh) values All Reset Setup Range Description rESEt Resets all parameters(Demand, Maximum/Minimum, and Energy) Page 190 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 191
A demand time sync command is issued so that a demand sub-interval can start at the end of a demand sync operation. It works only when the demand sync mode is set to manual sync. ⓒ 2011 Rootech Inc. All Rights Reserved Page 191...
2. The duty cycle for a pulse features the pulse period and the pulse on time. 3. It applies when the polarity of the output is set to 「normal」. If 「Reverse」 is selected, the closed contact and the open contact operate reversely. Page 192 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 193
If the digital output type is set to countable pulse(PuLS.C), the screen switches to the setup screen for the accumulated energy parameter. ⓒ 2011 Rootech Inc. All Rights Reserved Page 193...
Page 194
For all the events mentioned above, the Event LED operates with the OR logic. Therefore, if you select “Event LED,” the digital output operates even when any of the above events occurs. Page 194 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 195
(default 1.00) 0.01 - 99.99 Unit: kWh, kVARh when the energy unit is set to kWh Unit: Wh, VARh when the energy unit is set to Wh 1. d → decimal number ⓒ 2011 Rootech Inc. All Rights Reserved Page 195...
Page 196
When DO polarity is reverse The contact is closed. The contact is open. Event on DI Channel 1 Accura 2300S supports 2 digital input channels. Event setup for the DI channel 1 is as follows. Setup Range Description oFF (default)
Controlling the Display Screens of Accura 2350 Modules This setup screen allows you to control the display screens of all Accura 2350 modules connected to Accura 2300S to display the same information. The table below provides information on three-phase measurement modules.
Page 198
If the blinking of the LCD backlight is enabled, it blinks alternatively at the highest brightness and medium brightness. LCD Backlight On/Off Cycle When Events Occur Setup Range Description 0.1- 10.0 (default: 1.0) Setup for the LCD On/Off cycle [s] when an event occurs Page 198 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 199
3-phase balance demo mode enabled UnbaL 3-phase unbalance demo mode enabled dIP.S Short dip demo mode enabled dIP.L Long dip demo mode enabled SUL.S Short swell demo mode enabled SUL.L Long swell demo mode enabled ⓒ 2011 Rootech Inc. All Rights Reserved Page 199...
1. d → decimal number Application Version Display Description [d].[d].[d][d][d] Software version of the CPU application 1. d → decimal number Firmware Version Display Description [d].[d].[d][d][d] MCU firmware version 1. d → decimal number Page 200 ⓒ 2011 Rootech Inc. All Rights Reserved...
Start Event and End Event Accura 2300S generates a start event when power quality events such as Dip(Sag), Swell, and Fuse Fail events are set, and the condition for the occurrence of an event is satisfied. It also generates an end event when the measured value gets back to the normal state.
2. Press the button for more than 1 second. A beeping sound occurs in one second. Note If there is no button operation for 10 minutes in the event log mode, the screen automatically returns to the display mode. Page 202 ⓒ 2011 Rootech Inc. All Rights Reserved...
The newest event log Event Timestamp You can check the timestamp of the selected event by pressing the Down(v) arrow button when the event log screen is selected with the Left(<)/Right(>) arrow buttons. ⓒ 2011 Rootech Inc. All Rights Reserved Page 203...
2. It indicates the information on the phase or line-to-line where the event occurred. In 3P4W mode, the phase(A, B, C) is displayed, but in 3P3W mode, the line-to-line(AB, BC, CA) voltage is displayed. Page 204 ⓒ 2011 Rootech Inc. All Rights Reserved...
Fuse fail end event occurs on A phase. End event [d][d][d][d][d] ms Fuse failure duration time [ms] 1. d → decimal 2. It indicates the phase(A, B, C) where the event occurred. ⓒ 2011 Rootech Inc. All Rights Reserved Page 205...
A Cur.S Current event starts on A phase. [d][d][d][d] A Current [A] measured when an event occurs 1. d → decimal 2. It indicates the phase(A, B, C) where the event occurred. Page 206 ⓒ 2011 Rootech Inc. All Rights Reserved...
Event log number 000 - 999 LE ㅏ.E Leakage current event ends. [d][d][d][d] A Maximum leakage current [A] measured during the event [d][d][d][d][d] ms Leakage current event duration time [ms] 1. d → decimal ⓒ 2011 Rootech Inc. All Rights Reserved Page 207...
Demand current event ends on B phase. [d][d][d][d] A Maximum demand current [A] measured during the event [d][d][d][d][d] Demand current event duration time [min] 1. d → decimal 2. It indicates the phase where the event occurred. Page 208 ⓒ 2011 Rootech Inc. All Rights Reserved...
2. It indicates the phase(A, B, C, TOT) where the event occurred. No Event Log If there is no saved event log, the following text is displayed. Display Description Пo No event log Eunt ⓒ 2011 Rootech Inc. All Rights Reserved Page 209...
The following settings are required for Accura 2300S to operate properly. Step 1: Setup for the Voltage Wiring of Accura 2300S and PT Rating Set the voltage connection mode and PT rating(when using external PTs). If an external PT is not used, enter the same line-to-line voltage values for the primary voltage and the secondary voltage.
Step 2: Automatic Assignment of Accura 2350 Module IDs and Update of IDs Accura 2300S automatically assigns IDs to all connected Accura 2350 modules as shown in the following steps and updates the module IDs. Refer to 「Chapter 4 Accura 2300S Operation/Setup >...
Page 212
If step 2-2 is performed without performing step 2-1(automatic assignment of Standby IDs to Accura 2350 modules), module IDs are automatically assigned only to Accura 2350 modules with standby IDs, except for the Accura 2350 modules that already have specific module IDs(ID 0-39). Page 212 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 213
Accura 2300S. 4. to(Total): It indicates the total number of all Accura 2350 modules that are connected to Accura 2300S. 5. When Accura 2300S and Accura 2350 are connected, the number of Accura 2350 modules are automatically detected and displayed.
Chapter 4 Accura 2300S Operation/Setup Accura 2300S/2350 User Guide Step 3: Ethernet Setup of Accura 2300S Step 3-1 IP , Subnet Mask, and Gateway Setup for Accura 2300S ① Long press the SETUP button . → Go to the setup mode.
Chapter 5 Measurements General Measurement The general measurement parameters of Accura 2300S are shown in the following table. Some of the parameters are provided only via communications. The LCD screen on the front of the device provides measurement values obtained at 2-second aggregation intervals based on the measurement values obtained at a frame of 0.5 seconds.
Page 216
RMS current calculated by adding up three-phase currents. 8. The maximum/minimum values of the power factor are the absolute maximum/minimum values of the power factor. Page 216 ⓒ 2011 Rootech Inc. All Rights Reserved...
Accura 2300S/2350 User Guide Chapter 5 Measurements Measurement Event The following table shows the parameters for the measurement events provided via Accura 2300S and communication. Accura 2300S provides detailed information on the last 100 events through event logs. Event In the event log mode, the segment in the top menu bar lights up to indicate the event log mode.
– V – V – V – V Available Measurement Values Item Line-to-neutral Line-to-line voltage(rms) Current(rms) Active Power Voltage(rms) A Phase * PF B Phase * PF C Phase * PF Average/Total Page 218 ⓒ 2011 Rootech Inc. All Rights Reserved...
Voltage Wiring You can use 2 or 3 PTs(Potential Transformer) in 3-phase 3-wire mode. Its installation cost differs according to the number of PTs. However, regardless of how many PTs are used, Accura 2300S measures voltage signals in the same way.
Page 220
However, by using a virtual neutral point where the residual voltage value of the three phase voltages becomes zero, voltage and power values for each phase can be calculated. Page 220 ⓒ 2011 Rootech Inc. All Rights Reserved...
= 0 (The value becomes 0 in 1P3W mode.) – V Available Measurement Values Item Line-to-neutral Line-to-line Current(rms) Active Power Voltage(rms) Voltage(rms) A Phase * PF B Phase C Phase * PF Average/ Total ⓒ 2011 Rootech Inc. All Rights Reserved Page 221...
= 0 (The value becomes 0 in 1P2W mode.) = 0 (The value becomes 0 in 1P2W mode.) Available Measurement Values Item Line-to-neutral Line-to-line Current(rms) Active Power Voltage(rms) Voltage(rms) A Phase * PF B Phase C Phase Average/Total Page 222 ⓒ 2011 Rootech Inc. All Rights Reserved...
1 Cycle RMS Measurement with Half-cycle Sliding Window Accura 2300S measures the RMS voltage over 1 cycle using a half-cycle sliding window. The time resolution for the RMS value measured over 1 cycle is one half cycle. Dips(Sags)/Swells are detected based on the RMS value measured over 1 cycle.
= 3 ∗ ∶ zero − sequence component current Refer to 「Chapter 5 Measurement > Negative-sequence/Zero-sequence Unbalance」 for details about the zero-sequence component of current. Page 224 ⓒ 2011 Rootech Inc. All Rights Reserved...
The sign of the reactive power is the same as the sign of the reactive power calculated with fundamental frequency components. where k=a,b,c = ±√ − ⓒ 2011 Rootech Inc. All Rights Reserved Page 225...
The total apparent power is calculated based on the vector sum of the total active power and total reactive power. (Vector sum) = √ + Fig 5.7 Vector Sum for the Total Apparent Power | St | Page 226 ⓒ 2011 Rootech Inc. All Rights Reserved...
If the current leads or lags the voltage by a phase angle, the power factor is displayed as LEAD or LAG on the screen on the front of Accura 2300S. If the reactive power is zero, the information is not displayed.
Based on the average value, the predicted demand value at the end of the demand subinterval is calculated. Fig 5.11 Predicted Demand Calculation ⓒ 2011 Rootech Inc. All Rights Reserved Page 229...
3.80 (updated every second) Demand Sync Accura 2300S supports two methods for synchronizing the starting time of a demand sub-interval. 1) Hourly Auto Sync: automatically synchronizes the starting time of a demand sub-interval every hour 2) Manual Sync: synchronizes the starting time of a demand sub-interval at the time users issue a sync command For hourly auto sync, synchronization is performed every 60 minutes.
64 samples are taken per cycle for analysis of current harmonics, and the THD is calculated with harmonics up to the 31st order. √∑ =2 THD = where I : fundamental current, I : k-th harmonic current ⓒ 2011 Rootech Inc. All Rights Reserved Page 231...
ℎ, Iph,avg : Average value of three-phase currents Max( Iph) : Maximum difference between the three-phase current value and the average value of Δ three-phase currents ∣Current – the average current∣ Page 232 ⓒ 2011 Rootech Inc. All Rights Reserved...
− = Zero-Sequence Unbalance It is the ratio between the magnitudes of the zero-sequence component and the positive-sequence component. × 100 [ % ] − = ⓒ 2011 Rootech Inc. All Rights Reserved Page 233...
Fig 5.15 Aggregation Process Fixed Aggregation Accura 2300S provides six aggregation intervals from Aggregation 1 through 6 (1 second, 5 seconds, 1 minute, 5 minutes, 1 hour, and 6 hours). In the fixed aggregation interval, the offset time for the start of the aggregation interval is fixed to zero.
Page 235
Aggregation 201 2 seconds Aggregation 202 1. Accura 2300S’ LCD screen displays the values measured at 2-second aggregation intervals and updated every 0.5 seconds. 2. Accura 2300S’ LCD screen displays the max/min values among the values obtained during the aggregation interval of 0.5 seconds after resetting the values.
Page 236
By selecting an aggregation interval, users can collect the data on the selected aggregation interval via communication using the Modbus map. Because the aggregated data are stored in the circular buffer of Accura 2300S for a certain period of time, users can collect aggregated measurement values with greater flexibility.
Accura 2300S/2350 User Guide Appendix A Specifications Appendix A Specifications Accura 2300S Distribution Panel Digital Power Meter Control Power Supply Port name L+, N-, G(Earth Ground) Connector type Screw-type terminal (pluggable) Wire specification 2.1 – 4.0 mm (14 – 12 AWG), copper or aluminum Rated temperature of the Above 70 ˚C...
Page 238
Line-to-neutral/Line-to-line voltage unbalance as per the NEMA standard Voltage unbalance according to symmetrical components(negative-/zero-sequence components) General Number of temperature 1 (located at the rear of the device) sensors Weight 550 g Page 238 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 239
(26 AWG). It is recommended to keep a distance of over 5 mm from the power lines generating high levels of noise. 5. It indicates the maximum length of the 6C telephone line used to connect Accura 2300S to all Accura 2350 modules with each port(RJ12-1 or RJ12-2) on Accura 2300S.
Page 240
Accura 2350-1PSH-30A-35 Ф9.0 mm 71 g Internal Communication Dedicated Connected with Accura 2300S or other Accura 2350 modules with the 6C telephone line communication Number of communication ports 2 (RJ12A, RJ12B) Measurement Frequency 50/60 Hz, 42 – 69 Hz...
Page 241
The value can be set to the rated current(default) or peak demand current(only available via communication). 7. The data are unavailable on the LCD screen of Accura 2300S and are only available via communication. ∑ ( ...
Page 242
188 g Accura 2350-1PSC-60A-50 13.0 x 31.7 mm 158 g Internal Communication Dedicated Connected with Accura 2300S or other Accura 2350 modules with the 6C telephone line communication Number of communication ports 2 (RJ12A, RJ12B) Measurement Frequency 50/60 Hz, 42 – 69 Hz...
Page 243
The value can be set to the rated current(default) or peak demand current(only available via communication). 9. The data are unavailable on the LCD screen of Accura 2300S and are only available via communication. ∑ ( ...
Page 244
Single-hole Accura 2350-1PSCSH-400A 33.5 x 41.2 mm 383 g Internal Communication Dedicated Connected with Accura 2300S or other Accura 2350 modules with the 6C telephone line communication Number of communication ports 2 (RJ12A, RJ12B) Measurement Frequency 50/60 Hz, 42 – 69 Hz...
Page 245
The value can be set to the rated current(default) or peak demand current(only available via communication). 5. The data are unavailable on the LCD screen of Accura 2300S and are only available via communication. ∑ ( ...
Page 246
-20 to 60 C (-4 to 149 ℉) Storage temperature -40 to 85 C (-40 to 185 ℉) Operating humidity 5 – 95 % (non-condensing) Operating altitude Up to 2,000 m 1. Compliant with UL 61010-1(3rd edition) Page 246 ⓒ 2011 Rootech Inc. All Rights Reserved...
IEC 61000-4-11 Voltage dips, short interruptions and voltage variations Certification UL 61010-1 3rd edition, IEC 61010-2-030 EN 61326-1, EN 61326-2-1, EN 61010-1 KN 22, KN 24 General Warranty period 2 years ⓒ 2011 Rootech Inc. All Rights Reserved Page 247...
Page 248
Crest Factor Class 0.2 Class 0.5 (Harmonic) PMD Sx 10 % In – Imax 45 Hz to 15 times ±0.2 % ±0.5 % rated frequency PMD Dx 20 % Ib – Imax Page 248 ⓒ 2011 Rootech Inc. All Rights Reserved...
Page 249
PMD Sx 50 % Un – Umax 20 % Ib – Imax 10 % In – Imax 0.5 inductive – ±0.005 0.8 capacitive 1. There is no unit for the value. ⓒ 2011 Rootech Inc. All Rights Reserved Page 249...
1. It is the value measured by externally installing CTs. 2. The Imin value for Class 1S is 1 % In, and the Imin value for Class 1 is 2 % In. Page 250 ⓒ 2011 Rootech Inc. All Rights Reserved...
5. It indicates the measuring range and minimum measured value for Accura 2350-3PSC/1PSC modules. 6. The data are not displayed on the LCD screen of Accura 2300S and provided only via communication. 7. It indicates the measurement accuracy for when the error of the external ZCT is zero.
Immunity to conducted disturbances, induced by 10 V radio-frequency fields IEC 61000-4-8 Power frequency magnetic field immunity test 30 A/m IEC 61000-4-11 Voltage dips, short interruptions and voltage 0.5 cycles, variations each polarity 100 % Page 252 ⓒ 2011 Rootech Inc. All Rights Reserved...
Appendix E Ordering Information Accura 2300S/2350 User Guide Appendix E Ordering Information Accura 2300S Distribution Panel Digital Power Meter Accura 2300S Accura 2300S Accura 2350-3P/1P/1PSH Three-phase/Single-phase/Single-phase Single-hole Power Measuring Module Accura 2350 Type Basic Current Size[mm] Accura 2350 250A Accura 2350...
Page 255
IDC(DC Current Input) module Accura 2350 - 50V VDC(DC Voltage Input) module Accura 2350 - 50V - 80A DCM module(DC 50 V/80 A) Accura 2350 - 500V - 80A DCM module(DC 500 V/80 A) ⓒ 2011 Rootech Inc. All Rights Reserved Page 255...
Page 256
Accura 2300/2350, Accura 2300S/2350, Accura 2700/2750, Accura 3000, Accura 3300E, Accura 3300S/3300, Accura 3500S/3500, Accura 3550S/3550, Accura 3700, Accura 5500, and Accura 7500 are trademarks of Rootech Inc. Contact us for detailed product specifications and ordering information. Information contained herein is subject to change without notice.
Need help?
Do you have a question about the ACCURA 2300S and is the answer not in the manual?
Questions and answers