  • Page 2 Accura 2300/2350 Setup Procedure Step 1 Step 2 Accura 2350 Accura 2300...
  • Page 3 Accura 2350 Button Operation Button Move to the next menu item Short press /Change value. Select the menu item to change* Long press /Save the changed value. *Makes menu item changeable(blinking)
  • Page 4 Accura 2350 Setup Menu Displays menu item in the following order when short pressing th SET button. 3P Module(Three Phase) ID * Phase Sequence Load Load Phase CT ratio * (CT5A Module only) /Load Direction * Connection Selection Rated Current LCD Display Leakage Direction...
  • Page 5 Accura 2350-3P CT5A Setup CT Ratio Setup range (0~999) Setup range ex) Primary Rated Current = 100A and (0~39) Secondary Rated Current = 5A, then CT ratio = 100A/5A = 20 Phase Sequence/Load Direction ex) Three Phase 3-wire/4-wire 3CT Through-hole Wiring Setup range Load Direction SHORTING...
  • Page 6 Accura 2350- Setup Setup range (0~39) Phase Sequence/Load Direction ex) Three Phase 4-wire/3-wire Through-hole Wiring Setup range Load Direction L1(A) LOAD L1(A) LOAD L2(B) L3(C) L2(B) LOAD L3(C) L3(C) L2(B) L1(A)
  • Page 7 Accura 2350- Setup Wiring/Load Direction Load Direction Setup range Setup range (0~39) (Line to Neutral) (Line to Line) Phase Sequence ex) Single Phase LN(Line to Neutral) Through-hole Wiring Setup range Load Direction N L1 L1(A) LOAD L1(A) LOAD LOAD L1(A) L3(C)
  • Page 8 Accura 2350- 1PSCSH Setup Setup range (0~39) Wiring/Load Direction Setup range Load Direction (Line to Neutral) (Line to Line)
  • Page 9 Accura 2350- 1PSCSH Setup Phase Sequence(Three Phase 3-wire/4-wire, with 3 Modules) L1(A) L2(B) L3(C) Load Direction Phase Sequence(Three Phase 3-wire, with 2 Modules) Load Direction LOAD Setup range LOAD...
  • Page 10 Accura 2300 Button Operation Long press setup button to enter setup mode Button Short Move to the next menu item Press /Change value. Do not save Long Enter Enter Select /Exit Setup Mode Event Mode Press Save Setup mode *Makes menu item changeable(blinking)
  • Page 11 Accura 2300 Setup Menu Select the menu item by short pressing buttons. ※ Refer to the User Guide for details A2350 Meter Event Information Module ID Voltage Wiring * DIP Event Module ID * Serial Number PT Rating * Swell Event...
  • Page 12 Setup (Three Phase (Three Phase (Single Phase (Single Phase (Three Phase range 3-wire 4-wire) 3-wire) 3-wire) 2-wire) Open-delta)* *Some old Accura 2300 that does not support 3P3W connection operates as " ", even if it is set to " "...
  • Page 13 Accura 2300 Wiring(Three Phase) Three Phase 4-wire Three Phase 3-wire Direct Connection Direct Connection Fuse Fuse Three Phase 4-wire Three Phase 3-wire 3PT Connection 2PT Connection Fuse Fuse Fuse Fuse...
  • Page 14 Accura 2300 Wiring(Single Phase) Single Phase 3-wire Single Phase 2-wire Direct Connection Direct Connection Fuse Fuse Single Phase 3-wire Single Phase 2-wire 2PT Connection 1PT Connection Fuse Fuse Fuse Fuse...
  • Page 15 Accura 2300 PT Rating PT Rating Secondary Primary (PT Secondary (PT Primary line-to-line line-to-line voltage rating) voltage rating) 001 ~ 999 000001 ~ 999999 Setup Setup range range For direct connection without PTs, set the same value for both primary and secondary line-to-line voltage ratings.
  • Page 16 Accura 2350-1PSCSH Three Phase Group Assignment Three Phase 3-wire/4-wire with 3 Modules Three Phase 3-wire with 2 Modules How to Setup Long Press Short Press Short Press Long Press Move to the Select next digit Complete setup one of blinks. /Change value...
  • Page 17 Number of communicable IDs (Communication) Number of conflict/ standby IDs (Conflict) Total number of Accura 2350s connected (Total) to Accura 2300 Update module ID information (ID update) How to Setup Long Press Long Press Long Press Return to Stops blinking.