Summary of Contents for Arada Stoves Farringdon 16
Page 1
Arada Stoves LTD Project # 035-S-075-1 Model: Farringdon 16 Type: Free Standing Residential Catalytic Wood Fired Heater February 24, 2017 (Dirigo) Revised: July 11, 2022, August 30, 2022 EPA Test Method 28R for Certification and Auditing of Wood Heaters Contact: Mr.
Page 2
Project # 035-S-075-1 Model: Farringdon 16 Revision: July 11, 2022 • Changed CO from g/hr to g/min • Updated Summary Table for clarity. • Added 1 hour emissions in g/hr for all runs. • Added train precision criteria table. •...
Affidavit: Dirigo Laboratories, Inc. was contracted by Arada Stoves Ltd. to provide testing services for the Farringdon 16 catalytic wood fired heater per EPA Method 28R for Certification and Auditing of Wood Heaters. All testing and associated procedures were conducted at Dirigo Laboratories, Inc. beginning on 2/14/2017 and ending on 2/17/2017.
Introduction: Arada Stoves Ltd. of Axminster, United Kingdom, contracted with Dirigo Laboratories, Inc. to perform EPA certification testing for their Model Farringdon 16 catalytic wood heater. All testing was performed at Dirigo Laboratories, Inc. Testing was performed by Mr. Ben Nelke.
Project # 035-S-075-1 Model: Farringdon 16 Test Procedures and Equipment: All Sampling and analytical procedures were performed by Ben Nelke. All procedures used are directly from EPA Method 28R, ASTM E2780-10 and ASTM E2515-11. See the list below for equipment used. See Appendix D for calibration data.
Model: Farringdon 16 Results: For the Farringdon 16 wood heater, the weighted average emission rate is 1.5 g/hr with a weighted average efficiency of 77.2% and a weighted average CO of 0.91 g/min. The Arada Stoves Ltd. Model Farringdon 16 catalytic free standing wood heater meets the 2020 PM emission standard of ≤...
Project # 035-S-075-1 Model: Farringdon 16 Summary Table: Run 1 Run 2 Run 3 Run 4 Run 5 Date 2/14/17 2/15/17 2/16/17 2/17/17 2/17/17 Run Number Emission Rate (g/hr) 0.91 1.06 1.99 1.53 1.68 Burn Rate (kg/hr) 0.59 0.77 0.98 1.29...
Page 14
Project # 035-S-075-1 Model: Farringdon 16 Run 3: Run 3 was an attempt at a category II burn rate performed on 2/16/17, resulting in a 0.98 kg/hr burn rate. The test duration was 4 hours 10 minutes. The fuel weight was 10.7 lbs.
Project # 035-S-075-1 Model: Farringdon 16 Precision: Dual Train Comparison (ASTM E2515 11.7 - If either criterion (7.5% of average or 0.5 g/kg difference) is met, the run is valid. <0.5 g/kg Train A % Train B % <7.5% of...
Project # 035-S-075-1 Model: Farringdon 16 Filter Catch: Run 1: Project # 035-S-075-1 Arada Run # Model Farringdon 16 Date 2/21/17 Train A Front Rear Filter # Tare Final Train B Front Rear Filter # Tare Final First Hour 3028 0.1175...
Project # 035-S-075-1 Model: Farringdon 16 Run 3: Project # 035-S-075-1 Arada Run # Model Farringdon 16 Date 2/21/17 Train A Front Rear Filter # Tare Final Train B Front Rear Filter # Tare Final First Hour 3040 0.1181 0.1234 0.0053...
Page 18
Project # 035-S-075-1 Model: Farringdon 16 Run 5: Project # 035-S-075-1 Arada Run # Model Farringdon 16 Date 2/21/17 Train A Front Rear Filter # Tare Final Train B Front Rear Filter # Tare Final First Hour 3052 0.1172 0.1202 0.0030...
Project # 035-S-075-1 Model: Farringdon 16 Test Condition Summary: All testing conditions for all runs fell within allowable specifications of EPA Method 28R, ASTM E2780-10 and ASTM E2515-11. A summary of facility conditions, temperature averages, fuel burned and run times is listed below.
Project # 035-S-075-1 Model: Farringdon 16 Process Operations and Description: The appliance was operated according to procedures as described in the Operations Manual. Detailed run information can be found in corresponding digital folders submitted with this report. Settings & Run Notes...
Project # 035-S-075-1 Model: Farringdon 16 Test Fuel Properties: Fuel consisted of 2”x4”x17.5” and 4”x4”x17.5” Green, Douglas fir. Detailed fuel load specifications for each run can be found in the corresponding digital folders submitted with this report. Pre-burn Configuration: Page | 27...
Project # 035-S-075-1 Model: Farringdon 16 Sampling Locations and Descriptions: Sample ports are located 16.5 feet downstream from any disturbances and 1 foot upstream from any disturbances. Flow rate traverse data was collected 12 feet downstream from any disturbances and 5.5 feet upstream from any disturbances. (See...
Project # 035-S-075-1 Model: Farringdon 16 Sampling Methods: EPA ASTM E2515-11 was used in collecting particulate samples. The dilution tunnel is 6 inches in diameter. All sampling conditions per ASTM E2515-11 were followed. No alternate procedures were used. Analytical Methods Description: All sample recovery and analysis procedures followed EPA ASTM E2515-11 procedures.
Project # 035-S-075-1 Model: Farringdon 16 Sampling and Analytical Procedures All Sampling and analytical procedures were performed by Ben Nelke. All procedures used were directly from EPA Method 28R, ASTM 2515-11 and ASTM E2780-10. No alternative procedures were used for this test series.
Project # 035-S-075-1 Model: Farringdon 16 List of Appendices: The following appendices have been submitted electronically in conjunction with this report: Appendix A – Test Run Data, Technician Notes, and Sample Analysis Appendix B – Labels and Manuals Appendix C –Equipment Calibration Records Appendix D –...
Page 39
Project # 035-S-075-1 Model: Farringdon 16 Appendix A: Test Run Data Page | 38...
Page 40
Client ARADA Model FARRINGDON 16 Run # BRK2 Project # 00000 Tracking # Date 12_5_16 Notes:Medium Burn rate setting Time FLUE CAT CH 3 CH 4 CH 5 CH 6 CH 7 SCALE CH 9 CH 10 CH 11 CH 12...
Page 42
Client ARADA Model FARRINGDON 16 Run # BRK3 Project # 00000 Tracking # Date 12_6_16 Notes:Medium Burn rate setting Time FLUE CAT SCALE 9:10:59 AM 9:20:59 AM 9:30:59 AM 9:40:59 AM 9:50:59 AM 10:00:59 AM 10:10:59 AM 10:20:59 AM 10:30:59 AM...
Page 44
Client ARADA Model FARRINGDON 16 Run # BRK4 Project # 00000 Tracking # Date 12_7_16 Notes:Medium Burn rate setting Time FLUE CAT SCALE 9:10:27 AM 9:20:27 AM 9:30:27 AM 9:40:27 AM 9:50:27 AM 10:00:27 AM 10:10:27 AM 10:20:27 AM 10:30:27 AM...
Page 48
Client ARADA Model FARRINGDON 16 Run # BRK7 Project # 00000 Tracking # Date 12_13_16 Notes:Medium Burn rate setting Time FLUE CAT SCALE 11:08:01 AM 11:18:01 AM 11:28:01 AM 11:38:01 AM 11:48:01 AM 11:58:01 AM 12:08:01 PM 12:18:01 PM 12:28:01 PM...
Page 49
Client ARADA Model FARRINGDON 16 Run # BRK8 Project # 00000 Tracking # Date 12_14_16 Notes:Medium Burn rate setting Time FLUE CAT SCALE 9:14:31 AM 9:24:31 AM 9:34:31 AM 9:44:31 AM 9:54:31 AM 10:04:31 AM 10:14:31 AM 10:24:31 AM 10:34:31 AM...
Page 51
1:44:31 AM 1:54:31 AM 2:04:31 AM 2:14:31 AM 2:24:31 AM 2:34:31 AM 2:44:31 AM 2:54:31 AM 3:04:31 AM 3:14:31 AM 3:24:31 AM 3:34:31 AM 3:44:31 AM 3:54:31 AM 4:04:31 AM 4:14:31 AM 4:24:31 AM 4:34:31 AM 4:44:31 AM 4:54:31 AM 5:04:31 AM 5:14:31 AM 5:24:31 AM...
Page 56
1st hr 035-S-075-1_Run # EPA5_2_17_17_report.xls BOX A 7/6/2022 JOB # 035-S-075-1 71.4 TECHNICIAN: ROOM TEMP (F) DATE: BAROMETRIC PRESSURE ( In.Hg.) 29.60 2_17_17 29.60 29.60 29.60 RUN #: EPA5 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.01 FRONT FILTER #: 3052&3057 REAR FILTER #:...
Page 57
1st hr 035-S-075-1_Run # EPA5_2_17_17_report.xls BOX A 7/6/2022 TEST START TIME: 17:24 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP...
Page 58
1st hr 035-S-075-1_Run # EPA5_2_17_17_report.xls BOX A 7/6/2022 TEST START TIME: 17:24 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP...
Page 59
1st hr 035-S-075-1_Run # EPA5_2_17_17_report.xls RESULTS JOB NUMBER 035-S-075-1 RUN # EPA5 2_17_17 DATE: SAMPLE A SAMPLE B INFORMATION INFORMATION BURN RATE 8.48 0.00 4.01 KG/HR DRY Total Sample Volume - Vm 14.42 14.42 Average Gas Velocity in Dilution Tunnel - vs feet/second feet/second 8845.50...
Page 62
1st hr 035-S-075-1_Run # EPA4_2_17_17_report.xls BOX A 7/6/2022 JOB # 035-S-075-1 68.0 TECHNICIAN: ROOM TEMP (F) DATE: BAROMETRIC PRESSURE ( In.Hg.) 29.60 2_17_17 29.60 29.60 29.60 RUN #: EPA4 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.01 FRONT FILTER #: 3046&3051 REAR FILTER #:...
Page 63
1st hr 035-S-075-1_Run # EPA4_2_17_17_report.xls BOX A 7/6/2022 TEST START TIME: 12:54 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP...
Page 64
1st hr 035-S-075-1_Run # EPA4_2_17_17_report.xls BOX A 7/6/2022 TEST START TIME: 12:54 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP...
Page 65
1st hr 035-S-075-1_Run # EPA4_2_17_17_report.xls RESULTS JOB NUMBER 035-S-075-1 RUN # EPA4 2_17_17 DATE: SAMPLE A SAMPLE B INFORMATION INFORMATION BURN RATE 8.42 0.00 4.09 KG/HR DRY Total Sample Volume - Vm 13.94 13.94 Average Gas Velocity in Dilution Tunnel - vs feet/second feet/second 8931.40...
Page 68
1st hr 035-S-075-1_Run # EPA3_2_16_17_report.xls BOX A 7/6/2022 JOB # 035-S-075-1 69.9 TECHNICIAN: ROOM TEMP (F) DATE: BAROMETRIC PRESSURE ( In.Hg.) 29.56 2_16_17 29.56 29.56 29.56 RUN #: EPA3 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.01 FRONT FILTER #: 3040&3045 REAR FILTER #:...
Page 69
1st hr 035-S-075-1_Run # EPA3_2_16_17_report.xls BOX A 7/6/2022 TEST START TIME: 12:53 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP...
Page 70
1st hr 035-S-075-1_Run # EPA3_2_16_17_report.xls BOX A 7/6/2022 TEST START TIME: 12:53 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP...
Page 71
1st hr 035-S-075-1_Run # EPA3_2_16_17_report.xls RESULTS JOB NUMBER 035-S-075-1 RUN # EPA3 2_16_17 DATE: SAMPLE A SAMPLE B INFORMATION INFORMATION BURN RATE 8.43 0.00 4.07 KG/HR DRY Total Sample Volume - Vm 13.93 13.93 Average Gas Velocity in Dilution Tunnel - vs feet/second feet/second 9156.29...
Page 74
1st hour 035-S-075-1_Run # EPA2_2_15_17_report.xls BOX A 7/6/2022 JOB # 035-S-075-1 70.0 TECHNICIAN: ROOM TEMP (F) DATE: BAROMETRIC PRESSURE ( In.Hg.) 29.72 2_15_17 29.72 29.72 29.72 RUN #: EPA2 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.01 FRONT FILTER #: 3034&3039 REAR FILTER #:...
Page 75
1st hour 035-S-075-1_Run # EPA2_2_15_17_report.xls BOX A 7/6/2022 TEST START TIME: 13:39 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP...
Page 76
1st hour 035-S-075-1_Run # EPA2_2_15_17_report.xls BOX A 7/6/2022 TEST START TIME: 13:39 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP...
Page 77
1st hour 035-S-075-1_Run # EPA2_2_15_17_report.xls RESULTS JOB NUMBER 035-S-075-1 RUN # EPA2 2_15_17 DATE: SAMPLE A SAMPLE B INFORMATION INFORMATION BURN RATE 8.45 0.00 4.00 KG/HR DRY Total Sample Volume - Vm 13.40 13.40 Average Gas Velocity in Dilution Tunnel - vs feet/second feet/second 8842.48...
Page 78
1st hour 035-S-075-1_Run # EPA1_2_14_17_report.xls PREBURN PREBURN 035-S-075-1 ARADA_FARRINGDON16 Model Designation 2_14_17 EPA1 Tunnel Traverse Information NG INTERVAL: Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 0.038 0.032 0.036 0.042 0.040 0.035 0.040 0.043 0.036 Temperature 100.000 TEMPERATURES SCALE FLUE LEFT RIGHT BACK...
Page 80
1st hour 035-S-075-1_Run # EPA1_2_14_17_report.xls BOX A 7/6/2022 JOB # 035-S-075-1 70.0 TECHNICIAN: ROOM TEMP (F) DATE: BAROMETRIC PRESSURE ( In.Hg.) 30.06 2_14_17 30.06 30.06 30.06 RUN #: EPA1 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.01 FRONT FILTER #: 3028&3033 REAR FILTER #:...
Page 81
1st hour 035-S-075-1_Run # EPA1_2_14_17_report.xls BOX A 7/6/2022 TEST START TIME: 15:18 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP...
Page 82
1st hour 035-S-075-1_Run # EPA1_2_14_17_report.xls BOX A 7/6/2022 TEST START TIME: 15:18 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP...
Page 83
1st hour 035-S-075-1_Run # EPA1_2_14_17_report.xls BOX B 7/6/2022 JOB # 035-S-075-1 TECHNICIAN: DATE: 2_14_17 RUN #: EPA1 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.002 FRONT FILTER #: 3030 REAR FILTER #: 3031 FINAL LEAK RATE (CFM): FINAL LEAK RATE (CFM): <0.01 IN-HG...
Page 84
1st hour 035-S-075-1_Run # EPA1_2_14_17_report.xls BOX B 7/6/2022 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE Dirigo Laboratories, Inc. Page 7 of 9...
Page 85
1st hour 035-S-075-1_Run # EPA1_2_14_17_report.xls BOX B 7/6/2022 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE #DIV/0! #DIV/0! 0.000 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #N/A #DIV/0!
Page 86
1st hour 035-S-075-1_Run # EPA1_2_14_17_report.xls RESULTS JOB NUMBER 035-S-075-1 RUN # EPA1 2_14_17 DATE: SAMPLE A SAMPLE B INFORMATION INFORMATION BURN RATE 8.35 0.00 4.10 KG/HR DRY Total Sample Volume - Vm 13.12 13.12 Average Gas Velocity in Dilution Tunnel - vs feet/second feet/second 8796.55...
Page 87
Client: Arada (kg/hr) (g/hr) Model: Farringdon 16 Run Number Burn Rate Emmisions Rate Tracking No.: 0.59 Project No.: 035-S-075-1 0.77 Test Dates: 2/14/17 - 2/17/17 0.98 1.29 2.01 Total Runs:...
Page 94
035-S-075-1_Run # EPA5_2_17_17_report.xls BOX A 3/15/2017 JOB # 035-S-075-1 71.4 TECHNICIAN ROOM TEMP (F) DATE: BAROMETRIC 29.60 2_17_17 29.60 29.60 29.60 RUN #: EPA5 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.01 FRONT FILTER #: 3052&3057 REAR FILTER # REAR FILTER #: 3053 FINAL LEAK RATE (CFM):...
Page 95
035-S-075-1_Run # EPA5_2_17_17_report.xls BOX A 3/15/2017 TEST START TIME: 17:24 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP TEMP TEMP...
Page 96
035-S-075-1_Run # EPA5_2_17_17_report.xls BOX A 3/15/2017 TEST START TIME: 17:24 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP TEMP TEMP...
Page 97
035-S-075-1_Run # EPA5_2_17_17_report.xls BOX B 3/15/2017 JOB # 035-S-075-1 TECHNICIAN DATE: 2_17_17 RUN #: EPA5 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.002 FRONT FILTER #: 3054 REAR FILTER #: 3055 FINAL LEAK RATE (CFM): FINAL LEAK RATE (CFM): <0.01 IN-HG <0.01...
Page 98
035-S-075-1_Run # EPA5_2_17_17_report.xls BOX B 3/15/2017 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE Dirigo Laboratories, Inc. Page 2 of 3...
Page 99
035-S-075-1_Run # EPA5_2_17_17_report.xls BOX B 3/15/2017 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE 16.857 0.140 100.301 -0.057 1.984167 1.599231 TOTAL Dirigo Laboratories, Inc. Page 3 of 3...
Page 100
Ambient Sample Results: JOB NUMBER: 035-S-075-1 TECHNICIAN: DATE: 2_17_17 RUN NUMBER: EPA5 METER Y FACTOR: 0.997 Sample Volume (L) Meter Temp °F ΔH ΔP Start 633.178 SAMPLE INFORMATION 633.178 Total Sample Volume - Vm Liters 22.360 ft³ Total Sample Volume - Vm 0.19 Average Sample Rate ft³/min...
Page 101
035-S-075-1_Run # EPA5_2_17_17_report.xls RESULTS JOB NUMBER 035-S-075-1 RUN # EPA5 DATE: 2_17_17 SAMPLE A SAMPLE B INFORMATION INFORMATION BURN RATE 17.08 16.86 2.01 KG/HR DRY Total Sample Volume - Vm 14.34 14.34 Average Gas Velocity in Dilution Tunnel - vs feet/second feet/second 8897.26...
Page 102
035-S-075-1_Run # EPA4_2_17_17_report.xls PREBURN PREBURN 035-S-075-1 ARADA_FARRINGDON16 JOB # Model Designation TECHNICIAN DATE: 2_17_17 RUN #: EPA4 Tunnel Traverse Information READING INTERVAL: Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 0.041 0.037 0.045 0.040 0.041 0.042 0.046 0.042 0.035 120.000 Temperature Run Time: TEMPERATURES...
Page 104
035-S-075-1_Run # EPA4_2_17_17_report.xls BOX A 3/15/2017 JOB # 035-S-075-1 68.0 TECHNICIAN ROOM TEMP (F) DATE: BAROMETRIC 29.60 2_17_17 29.60 29.60 29.60 RUN #: EPA4 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.01 FRONT FILTER #: 3046&3051 REAR FILTER # REAR FILTER #: 3047 FINAL LEAK RATE (CFM):...
Page 105
035-S-075-1_Run # EPA4_2_17_17_report.xls BOX A 3/15/2017 TEST START TIME: 12:54 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP TEMP TEMP...
Page 106
035-S-075-1_Run # EPA4_2_17_17_report.xls BOX A 3/15/2017 TEST START TIME: 12:54 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP TEMP TEMP...
Page 107
035-S-075-1_Run # EPA4_2_17_17_report.xls BOX B 3/15/2017 JOB # 035-S-075-1 TECHNICIAN DATE: 2_17_17 RUN #: EPA4 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.002 FRONT FILTER #: 3048 REAR FILTER #: 3049 FINAL LEAK RATE (CFM): FINAL LEAK RATE (CFM): <0.01 IN-HG <0.01...
Page 108
035-S-075-1_Run # EPA4_2_17_17_report.xls BOX B 3/15/2017 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE Dirigo Laboratories, Inc. Page 2 of 3...
Page 109
035-S-075-1_Run # EPA4_2_17_17_report.xls BOX B 3/15/2017 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE 26.665 0.140 100.246 -0.043 1.990526 1.6855 TOTAL Dirigo Laboratories, Inc. Page 3 of 3...
Page 110
Ambient Sample Results: JOB NUMBER: 035-S-075-1 TECHNICIAN: DATE: 2_17_17 RUN NUMBER: EPA4 METER Y FACTOR: 0.997 Sample Volume (L) Meter Temp °F ΔH ΔP Start 80.5 1003.027 SAMPLE INFORMATION 1003.027 Total Sample Volume - Vm Liters 35.422 ft³ Total Sample Volume - Vm 0.19 Average Sample Rate ft³/min...
Page 111
035-S-075-1_Run # EPA4_2_17_17_report.xls RESULTS JOB NUMBER 035-S-075-1 RUN # EPA4 DATE: 2_17_17 SAMPLE A SAMPLE B INFORMATION INFORMATION BURN RATE 27.04 26.67 1.29 KG/HR DRY Total Sample Volume - Vm 13.88 13.88 Average Gas Velocity in Dilution Tunnel - vs feet/second feet/second 8971.59...
Page 112
035-S-075-1_Run # EPA3_2_16_17_report.xls PREBURN PREBURN 035-S-075-1 ARADA_FARRINGDON16 JOB # Model Designation TECHNICIAN DATE: 2_16_17 RUN #: EPA3 Tunnel Traverse Information READING INTERVAL: Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 0.042 0.041 0.043 0.041 0.044 0.043 0.046 0.040 0.035 105.000 Temperature Run Time: TEMPERATURES...
Page 114
035-S-075-1_Run # EPA3_2_16_17_report.xls BOX A 3/15/2017 JOB # 035-S-075-1 69.9 TECHNICIAN ROOM TEMP (F) DATE: BAROMETRIC 29.56 2_16_17 29.56 29.56 29.56 RUN #: EPA3 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.01 FRONT FILTER #: 3040&3045 REAR FILTER # REAR FILTER #: 3041 FINAL LEAK RATE (CFM):...
Page 115
035-S-075-1_Run # EPA3_2_16_17_report.xls BOX A 3/15/2017 TEST START TIME: 12:53 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP TEMP TEMP...
Page 116
035-S-075-1_Run # EPA3_2_16_17_report.xls BOX A 3/15/2017 TEST START TIME: 12:53 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP TEMP TEMP...
Page 117
035-S-075-1_Run # EPA3_2_16_17_report.xls BOX B 3/15/2017 JOB # 035-S-075-1 TECHNICIAN DATE: 2_16_17 RUN #: EPA3 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.002 FRONT FILTER #: 3042 REAR FILTER #: 3043 FINAL LEAK RATE (CFM): FINAL LEAK RATE (CFM): <0.01 IN-HG <0.01...
Page 118
035-S-075-1_Run # EPA3_2_16_17_report.xls BOX B 3/15/2017 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE 0.141 32.280 -0.01 1.99 1.54 0.142 33.695 -0.02 1.99 0.141 35.108 -0.02 1.99 1.56...
Page 119
035-S-075-1_Run # EPA3_2_16_17_report.xls BOX B 3/15/2017 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE 35.108 0.140 100.249 -0.026 1.9864 1.651923 TOTAL Dirigo Laboratories, Inc. Page 3 of 3...
Page 120
Ambient Sample Results: JOB NUMBER: 035-S-075-1 TECHNICIAN: DATE: 2_16_17 RUN NUMBER: EPA3 METER Y FACTOR: 0.997 Sample Volume (L) Meter Temp °F ΔH ΔP Start 1403.742 Total Sample Volume - Vm Total Sample Volume - Vm Average Sample Rate Sample Time Average Meter Temperature Total Sample Volume (Standard Conditions) - Vmstd Total Particulates...
Page 122
035-S-075-1_Run # EPA3_2_16_17_report.xls RESULTS JOB NUMBER 035-S-075-1 RUN # EPA3 DATE: 2_16_17 SAMPLE A SAMPLE B INFORMATION INFORMATION BURN RATE 35.65 35.11 0.98 KG/HR DRY Total Sample Volume - Vm 13.92 13.92 Average Gas Velocity in Dilution Tunnel - vs feet/second feet/second 9165.43...
Page 123
035-S-075-1_Run # EPA2_2_15_17_report.xls PREBURN PREBURN 035-S-075-1 ARADA_FARRINGDON16 JOB # Model Designation TECHNICIAN DATE: 2_15_17 RUN #: EPA2 Tunnel Traverse Information READING INTERVAL: Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 0.039 0.036 0.043 0.040 0.040 0.042 0.041 0.040 0.033 105.000 Temperature Run Time: TEMPERATURES...
Page 125
035-S-075-1_Run # EPA2_2_15_17_report.xls BOX A 3/15/2017 JOB # 035-S-075-1 70.0 TECHNICIAN ROOM TEMP (F) DATE: BAROMETRIC 29.72 2_15_17 29.72 29.72 29.72 RUN #: EPA2 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.01 FRONT FILTER #: 3034&3039 REAR FILTER # REAR FILTER #: 3035 FINAL LEAK RATE (CFM):...
Page 126
035-S-075-1_Run # EPA2_2_15_17_report.xls BOX A 3/15/2017 TEST START TIME: 13:39 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP TEMP TEMP...
Page 127
035-S-075-1_Run # EPA2_2_15_17_report.xls BOX A 3/15/2017 TEST START TIME: 13:39 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP TEMP TEMP...
Page 128
035-S-075-1_Run # EPA2_2_15_17_report.xls BOX B 3/15/2017 JOB # 035-S-075-1 TECHNICIAN DATE: 2_15_17 RUN #: EPA2 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.002 FRONT FILTER #: 3036 REAR FILTER #: 3037 FINAL LEAK RATE (CFM): FINAL LEAK RATE (CFM): <0.01 IN-HG <0.01...
Page 129
035-S-075-1_Run # EPA2_2_15_17_report.xls BOX B 3/15/2017 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE 0.142 32.294 -0.01 1.98 1.98 0.141 33.706 -0.01 1.67 0.142 35.123 -0.01 1.98 0.141...
Page 130
035-S-075-1_Run # EPA2_2_15_17_report.xls BOX B 3/15/2017 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE 43.609 0.141 100.262 -0.021 1.991613 1.735313 TOTAL Dirigo Laboratories, Inc. Page 3 of 3...
Page 131
Ambient Sample Results: JOB NUMBER: 035-S-075-1 TECHNICIAN: DATE: 2_15_17 RUN NUMBER: EPA2 METER Y FACTOR: 0.997 Sample Volume (L) Meter Temp °F ΔH ΔP Start 1736.481 98.5 SAMPLE INFORMATION 1736.481 Total Sample Volume - Vm Liters 61.323 ft³ Total Sample Volume - Vm 0.20 Average Sample Rate ft³/min...
Page 132
035-S-075-1_Run # EPA2_2_15_17_report.xls RESULTS JOB NUMBER 035-S-075-1 RUN # EPA2 DATE: 2_15_17 SAMPLE A SAMPLE B INFORMATION INFORMATION BURN RATE 44.28 43.61 0.77 KG/HR DRY Total Sample Volume - Vm 13.37 13.37 Average Gas Velocity in Dilution Tunnel - vs feet/second feet/second 8861.02...
Page 133
035-S-075-1_Run # EPA1_2_14_17_report.xls PREBURN PREBURN 035-S-075-1 ARADA_FARRINGDON16 Model Designation 2_14_17 EPA1 Tunnel Traverse Information NTERVAL: Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 0.038 0.032 0.036 0.042 0.040 0.035 0.040 0.043 0.036 100.000 Temperature TEMPERATURES SCALE FLUE LEFT RIGHT BACK BOTTOM STOVE READING...
Page 135
035-S-075-1_Run # EPA1_2_14_17_report.xls BOX A 3/15/2017 JOB # 035-S-075-1 70.0 TECHNICIAN ROOM TEMP (F) DATE: BAROMETRIC 30.06 2_14_17 30.06 30.06 30.06 RUN #: EPA1 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.01 FRONT FILTER #: 3028&3033 REAR FILTER # REAR FILTER #: 3029 FINAL LEAK RATE (CFM):...
Page 136
035-S-075-1_Run # EPA1_2_14_17_report.xls BOX A 3/15/2017 TEST START TIME: 15:18 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP TEMP TEMP...
Page 137
035-S-075-1_Run # EPA1_2_14_17_report.xls BOX A 3/15/2017 TEST START TIME: 15:18 TEMPERATURES GAS METER SAMPLE TUNNEL ORIFICE FILTER TUNNEL VEL Proportional Scale Weight TUNNEL FLUE FILTER FB REAR METER AMBIENT VOLUME DELTA P DELTA H FT/SEC Rate (%) Weight TEMP TEMP TEMP TEMP TEMP...
Page 138
035-S-075-1_Run # EPA1_2_14_17_report.xls BOX B 3/15/2017 JOB # 035-S-075-1 TECHNICIAN DATE: 2_14_17 RUN #: EPA1 READING INTERVAL: SAMPLE BOX : PROBE MATERIAL: METER Y FACTOR: 1.002 FRONT FILTER #: 3030 REAR FILTER #: 3031 FINAL LEAK RATE (CFM): FINAL LEAK RATE (CFM): <0.01 IN-HG <0.01...
Page 139
035-S-075-1_Run # EPA1_2_14_17_report.xls BOX B 3/15/2017 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE 0.141 32.054 -0.02 1.98 1.34 0.141 33.459 -0.01 1.97 1.53 0.140 34.863 -0.01 1.99...
Page 140
035-S-075-1_Run # EPA1_2_14_17_report.xls BOX B 3/15/2017 TEMPERATURES GAS METER SAMPLE FLUE ORIFICE FILTER LEFT RIGHT STOVE PROPORTIONAL FILTER METER VOLUME DRAFT DELTA H SIDE SIDE AVG T RATE(FT3/MIN) RATE 58.78 0.140 100.280 -0.011 1.986905 1.673023 TOTAL Dirigo Laboratories, Inc. Page 3 of 3...
Page 141
Ambient Sample Results: JOB NUMBER: 035-S-075-1 TECHNICIAN: DATE: 2_14_17 RUN NUMBER: EPA1 METER Y FACTOR: 0.997 Sample Volume (L) Meter Temp °F ΔH ΔP Start 2305.638 SAMPLE INFORMATION 2305.638 Total Sample Volume - Vm Liters 81.423 ft³ Total Sample Volume - Vm 0.19 Average Sample Rate ft³/min...
Page 142
035-S-075-1_Run # EPA1_2_14_17_report.xls RESULTS JOB NUMBER 035-S-075-1 RUN # EPA1 DATE: 2_14_17 SAMPLE A SAMPLE B INFORMATION INFORMATION BURN RATE 59.73 58.78 0.59 KG/HR DRY Total Sample Volume - Vm 13.08 13.08 Average Gas Velocity in Dilution Tunnel - vs feet/second feet/second 8823.54...
Page 143
Client: Arada (kg/hr) Model: Farringdon 16 Run Number Burn Rate Overall Efficiency Tracking No.: 0.59 81.1 Project No.: 035-S-075-1 0.77 83.4 Test Dates: 2/14/17 - 2/17/17 0.98 79.5 1.29 75.0 2.01 71.7 Total Runs:...
Page 147
VERSION: 2.4 4/15/2010 (Cat, Non-Cat, Pe Manufacturer: Appliance Type: Arada Model: Farringdon 16 (F or C) 2/21/2017 Date: Temp. Units (kg or lb) Run: Weight Units 035-S-075-1 Control #: est Duration: urn Category Fuel Data 19.9 Wood Moisture (% DRY): D.
Page 154
SUMS AVERAGE 4893.32 4928.96 3597.41 32054.24 504.53 23278.28 7474.39 5902.39 Energy Losses (kJ/kg of Dry Fuel) Total Flue Gas Constituent Loss H2O Comb H2O Fuel MC Rate 346.90 785.41 296.51 3855.51 -42.26 1779.53 568.34 7589.94 450.10 5.80 964.66 1347.39 434.40 1817.07 598.59 5618.00...
Page 155
SUMS 22484 2551 19932.91 57727 2551 183.05 12.60 Total Chemical Sensible and Total Chem Grams Produced Loss Loss 1 Latent Loss Output Loss 2 0.00 0.00 0.00 7334 1782 5552.58 18528 1782 120.96 10.05 3888 3321.53 11105 38.40 3.20 2778 2769.28 7717 1.99...
Page 156
Dirigo Laboratories, Inc. Manufacturer: Arada Model: Farringdon 16 Date: 2/21/2017 Run: Control #: 035-S-075-1 Test Duration: Output Category: HHV Basis LHV Basis Overall Efficiency 71.7% 77.5% Combustion Efficiency 96.8% 96.8% Heat Transfer Efficiency 74.1% 80.1% HHV Output Rate (kJ/h) 28,489...
Page 157
Default Fuel Values D. Fir 19,810 19,887 HHV (kJ/kg) 48.73 6.87 43.9 42.9 %Ash...
Page 158
VERSION: 2.4 4/15/2010 (Cat, Non-Cat, Pe Manufacturer: Appliance Type: Arada Model: Farringdon 16 (F or C) 2/21/2017 Date: Temp. Units (kg or lb) Run: Weight Units 035-S-075-1 Control #: est Duration: urn Category Fuel Data 19.7 Wood Moisture (% DRY): D.
Page 165
SUMS AVERAGE 5116.20 4732.37 6167.93 32354.99 1262.24 34089.28 10853.87 4728.84 Energy Losses (kJ/kg of Dry Fuel) Total Flue Gas Constituent Loss H2O Comb H2O Fuel MC Rate 225.05 654.20 191.41 3042.04 -137.94 1701.09 534.52 6210.37 268.90 151.21 211.46 1341.55 52.49 1712.83 544.86 4283.30...
Page 166
SUMS 20306 3430 16876.78 61541 3430 244.76 17.18 Total Chemical Sensible and Total Chem Grams Produced Loss Loss 1 Latent Loss Output Loss 2 0.00 0.00 0.00 2760 2592.54 10005 13.25 0.60 3271 1156 2115.16 8368 1156 78.59 6.50 3878 1941 1936.95 7010...
Page 167
Dirigo Laboratories, Inc. Manufacturer: Arada Model: Farringdon 16 Date: 2/21/2017 Run: Control #: 035-S-075-1 Test Duration: Output Category: HHV Basis LHV Basis Overall Efficiency 75.0% 81.0% Combustion Efficiency 95.8% 95.8% Heat Transfer Efficiency 78.3% 84.6% HHV Output Rate (kJ/h) 19,197...
Page 168
Default Fuel Values D. Fir 19,810 19,887 HHV (kJ/kg) 48.73 6.87 43.9 42.9 %Ash...
Page 169
VERSION: 2.4 4/15/2010 (Cat, Non-Cat, Pe Manufacturer: Appliance Type: Arada Model: Farringdon 16 (F or C) 2/21/2017 Date: Temp. Units (kg or lb) Run: Weight Units 035-S-075-1 Control #: est Duration: urn Category Fuel Data 19.3 Wood Moisture (% DRY): D.
Page 170
Manufacturer: Arada Model: Farringdon 16 Date: 2/21/2017 Run: Control #: 035-S-075-1 Test Duration: 79.5% 85.9% Comb Eff 96.0% 96.0% Ultimate CO2 HT Eff 82.8% 89.5% CO2-ult 19.64 Output 15,379 kJ/h Burn Rate 0.98 kg/h 1.063 Grams CO Input 19,348 kJ/h MC wet 16.18...
Page 171
Air Fuel Ratio (A/F) Overall Heating Efficiency: 79.5% Dry Molecular Weight (Md) 30.15 Combustion Efficiency: 96.0% Dry Moles Exhaust Gas (Nr): 340.28 Heat Transfer Efficiency: 82.8% Air Fuel Ratio (A/F) 9.75 0.88 Heat Output: 14,589 Btu/h 15,379 kJ/h Heat Input: 18,353 Btu/h 19,348...
Page 172
Combustion Efficiency: 96.0% Total Input (kJ): 80,615 76,459 (Btu) Total Output (kJ): 64,081 60,778 (Btu) Efficiency: 79.5% Total CO (g): 231.11 Load Weight (kg): Fuel Heating: Value in kJ/kg - CV: 81368 4.06 6.87 2.74 19810.00 16.18 79.64 21.12 2.87 Fuel Properties Mass Balance Total...
Page 175
SUMS AVERAGE 3859.17 2488.38 6694.72 20688.68 1701.01 42254.92 13182.66 3494.98 Energy Losses (kJ/kg of Dry Fuel) Total Flue Gas Constituent Loss H2O Comb H2O Fuel MC Rate 140.17 270.03 40.18 1400.75 -130.83 1636.45 503.99 3860.74 156.66 261.20 36.45 1416.62 -112.74 1646.72 507.74 3912.65...
Page 176
SUMS 16534 3231 13302.71 64835 3231 231.11 16.09 Total Chemical Sensible and Total Chem Grams Produced Loss Loss 1 Latent Loss Output Loss 2 0.00 0.00 0.00 1414 1441.18 5744 1.29 -0.73 736.39 3412 0.87 -0.25 588.30 2798 1.05 -0.13 692.19 3443 1.32...
Page 177
Dirigo Laboratories, Inc. Manufacturer: Arada Model: Farringdon 16 Date: 2/21/2017 Run: Control #: 035-S-075-1 Test Duration: Output Category: HHV Basis LHV Basis Overall Efficiency 79.5% 85.9% Combustion Efficiency 96.0% 96.0% Heat Transfer Efficiency 82.8% 89.5% HHV Output Rate (kJ/h) 15,379...
Page 178
Default Fuel Values D. Fir 19,810 19,887 HHV (kJ/kg) 48.73 6.87 43.9 42.9 %Ash...
Page 179
VERSION: 2.4 4/15/2010 (Cat, Non-Cat, Pe Manufacturer: Appliance Type: Arada Model: Farringdon 16 (F or C) 2/21/2017 Date: Temp. Units (kg or lb) Run: Weight Units 035-S-075-1 Control #: est Duration: urn Category Fuel Data 20.3 Wood Moisture (% DRY): D.
Page 193
SUMS 13165 12642.26 66406 49.06 0.49 Total Chemical Sensible and Total Chem Grams Produced Loss Loss 1 Latent Loss Output Loss 2 0.00 0.00 0.00 1492 1500.60 5979 2.66 -0.64 742.81 3742 0.79 -0.19 702.75 3410 0.78 -0.21 719.14 3768 0.48 -0.17 1297...
Page 195
Dirigo Laboratories, Inc. Manufacturer: Arada Model: Farringdon 16 Date: 2/21/2017 Run: Control #: 035-S-075-1 Test Duration: Output Category: HHV Basis LHV Basis Overall Efficiency 83.4% 90.1% Combustion Efficiency 99.3% 99.3% Heat Transfer Efficiency 83.9% 90.7% HHV Output Rate (kJ/h) 12,781...
Page 196
Default Fuel Values D. Fir 19,810 19,887 HHV (kJ/kg) 48.73 6.87 43.9 42.9 %Ash...
Page 197
VERSION: 2.4 4/15/2010 (Cat, Non-Cat, Pe Manufacturer: Appliance Type: Arada Model: Farringdon 16 (F or C) 2/21/2017 Date: Temp. Units (kg or lb) Run: Weight Units 035-S-075-1 Control #: est Duration: urn Category Fuel Data 20.6 Wood Moisture (% DRY): D.
Page 213
SUMS 15357 4063 11293.84 66253 4063 285.48 21.16 Total Chemical Sensible and Total Chem Grams Produced Loss Loss 1 Latent Loss Output Loss 2 0.00 0.00 0.00 972.72 4633 0.87 -0.45 565.86 3163 0.67 -0.16 605.81 3494 0.63 -0.12 654.50 3817 0.64 -0.10...
Page 215
Dirigo Laboratories, Inc. Manufacturer: Arada Model: Farringdon 16 Date: 2/21/2017 Run: Control #: 035-S-075-1 Test Duration: Output Category: HHV Basis LHV Basis Overall Efficiency 81.1% 87.7% Combustion Efficiency 95.0% 95.0% Heat Transfer Efficiency 85.4% 92.3% HHV Output Rate (kJ/h) 9,411...
Page 216
Default Fuel Values D. Fir 19,810 19,887 HHV (kJ/kg) 48.73 6.87 43.9 42.9 %Ash...
Page 217
Arada Farringdon16 Filter Catch Run#5.xlsm Project # 035-S-075-1 Arada Run # Model Farringdon 16 Date 2/21/17 Train A Front Rear Filter # Tare Final Train B Front Rear Filter # Tare Final First Hour 3052 0.1172 0.1202 0.0030 3054 3053 3055 0.2354...
Page 218
Arada Farringdon16 Filter Catch Run#4.xlsm Project # 035-S-075-1 Arada Run # Model Farringdon 16 Date 2-21-2-17 Train A Front Rear Filter # Tare Final Train B Front Rear Filter # Tare Final First Hour 3046 0.1174 0.1216 0.0042 3048 3047 3049 0.2357...
Page 219
Arada Farringdon16 Filter Catch Run#3.xlsm Project # 035-S-075-1 Arada Run # Model Farringdon 16 Date 2/21/17 Train A Front Rear Filter # Tare Final Train B Front Rear Filter # Tare Final First Hour 3040 0.1181 0.1234 0.0053 3042 3041 3043 0.2361...
Page 220
Arada Farringdon16 Filter Catch Run#2.xlsm Project # 035-S-075-1 Arada Run # Model Farringdon 16 Date 2/21/17 Train A Front Rear Filter # Tare Final Train B Front Rear Filter # Tare Final First Hour 3034 0.1179 0.1212 0.0033 3036 3035 3037 0.2354...
Page 221
Arada Farringdon16 Filter Catch Run#1.xlsm Project # 035-S-075-1 Arada Run # Model Farringdon 16 Date 2/21/17 Train A Front Rear Filter # Tare Final Train B Front Rear Filter # Tare Final First Hour 3028 0.1175 0.1206 0.0031 3030 3029 3031 0.2341...
Page 234
Weather History for Portland Troutdale, OR | Weather Underground Troutdale, OR History Weather History for KTTD - February, 2017 February 2017 View February 2017 Friday, February 17, 2017 Daily WeeklyMonthly Custom Actual Average Record 49 °F 43 °F 55 °F 50 °F 66 °F (1948) 43 °F...
Page 235
Weather History for Portland Troutdale, OR | Weather Underground T = Trace of Precipitation, MM = Missing Value Source: NWS Daily Summary Daily Weather History Graph | why ads? report this ad Search for Another Location Airport or City: KTTD Submit Trip Planner Search our weather history database for the weather conditions in past years.
Page 236
Weather History for Portland Troutdale, OR | Weather Underground | why ads? report this ad Astronomy Feb. 17, 2017 Rise Actual Time 7:07 AM PST 5:40 PM PST Civil Twilight 6:37 AM PST 6:10 PM PST Nautical Twilight 6:02 AM PST 6:45 PM PST Astronomical Twilight 5:28 AM PST...
Page 237
Weather History for Portland Troutdale, OR | Weather Underground 43.0 °F 38.8 °F 41.0 °F 29.74 in 10.0 mi 6.9 mph Partly Cloudy 43.0 °F 36.0 °F 39.9 °F 29.72 in 10.0 mi East 13.8 mph Clear 43.0 °F 38.2 °F 39.9 °F 29.70 in 10.0 mi...
Page 238
Weather History for Portland Troutdale, OR | Weather Underground Troutdale, OR History Weather History for KTTD - February, 2017 2017 View February 2017 Thursday, February 16, 2017 Daily WeeklyMonthly Custom Actual Average Record 46 °F 43 °F 51 °F 50 °F 63 °F (1981) 40 °F 35 °F...
Page 239
Weather History for Portland Troutdale, OR | Weather Underground T = Trace of Precipitation, MM = Missing Value Source: NWS Daily Summary Daily Weather History Graph | why ads? report this ad Search for Another Location Airport or City: KTTD Submit Trip Planner Search our weather history database for the weather conditions in past years.
Page 240
Weather History for Portland Troutdale, OR | Weather Underground | why ads? report this ad Astronomy Feb. 16, 2017 Rise Actual Time 7:09 AM PST 5:38 PM PST Civil Twilight 6:38 AM PST 6:09 PM PST Nautical Twilight 6:04 AM PST 6:43 PM PST Astronomical Twilight 5:29 AM PST...
Page 241
Weather History for Portland Troutdale, OR | Weather Underground 41.0 °F 35.8 °F 39.0 °F 29.50 in 4.0 mi East 8.1 mph 0.11 in Rain Rain 41.0 °F 34.7 °F 39.0 °F 29.49 in 4.0 mi East 10.4 mph 0.02 in Rain Rain 42.1 °F...
Page 242
Weather History for Portland Troutdale, OR | Weather Underground 44.1 °F 42.1 °F 29.80 in 10.0 mi Calm Calm Overcast https://www.wunderground.com/history/airport/KTTD/2017/2/16/DailyHistory.html?req_city=Clackamas&req_state=OR&req_statename=Oregon&reqdb.zip=97015&reqdb.magic=1&reqdb.wmo=99999[3/15/2017 5:39:51 PM]...
Page 243
Weather History for Portland Troutdale, OR | Weather Underground Troutdale, OR History Weather History for KTTD - February, 2017 2017 View February 2017 Wednesday, February 15, 2017 Daily WeeklyMonthly Custom Actual Average Record 41 °F 42 °F 43 °F 50 °F 63 °F (1981) 38 °F 35 °F...
Page 244
Weather History for Portland Troutdale, OR | Weather Underground Rain T = Trace of Precipitation, MM = Missing Value Source: NWS Daily Summary Daily Weather History Graph | why ads? report this ad https://www.wunderground.com/history/airport/KTTD/2017/2/15/DailyHistory.html?req_city=Clackamas&req_state=OR&req_statename=Oregon&reqdb.zip=97015&reqdb.magic=1&reqdb.wmo=99999[3/15/2017 5:37:57 PM]...
Page 245
Weather History for Portland Troutdale, OR | Weather Underground Search for Another Location Airport or City: KTTD Submit Trip Planner Search our weather history database for the weather conditions in past years. The results will help you decide how hot, cold, wet, or windy it might be! Date: Submit February...
Page 246
Weather History for Portland Troutdale, OR | Weather Underground | why ads? report this ad Hourly Weather History & Observations Temp. Windchill Dew Point Humidity Pressure Visibility Wind Dir Wind Speed Gust Speed Precip Events Conditions 42.1 °F 31.3 °F 30.0 °F 29.87 in 10.0 mi...
Page 247
Weather History for Portland Troutdale, OR | Weather Underground Troutdale, OR History Weather History for KTTD - February, 2017 2017 View February 2017 Tuesday, February 14, 2017 Daily WeeklyMonthly Custom Actual Average Record 43 °F 42 °F 47 °F 50 °F 62 °F (1977) 38 °F 35 °F...
Page 248
Weather History for Portland Troutdale, OR | Weather Underground 10 miles Rain T = Trace of Precipitation, MM = Missing Value Source: NWS Daily Summary Daily Weather History Graph | why ads? report this ad https://www.wunderground.com/history/airport/KTTD/2017/2/14/DailyHistory.html?req_city=Clackamas&req_state=OR&req_statename=Oregon&reqdb.zip=97015&reqdb.magic=1&reqdb.wmo=99999[3/15/2017 5:32:32 PM]...
Page 249
Weather History for Portland Troutdale, OR | Weather Underground Search for Another Location Airport or City: KTTD Submit Trip Planner Search our weather history database for the weather conditions in past years. The results will help you decide how hot, cold, wet, or windy it might be! Date: February Submit...
Page 250
Weather History for Portland Troutdale, OR | Weather Underground Hourly Weather History & Observations Temp. Windchill Dew Point Humidity Pressure Visibility Wind Dir Wind Speed Gust Speed Precip Events Conditions 39.9 °F 29.2 °F 27.0 °F 30.19 in 10.0 mi East 25.3 mph 35.7 mph...
Page 252
Operating & Installation Manual Farringdon 16 Wood Stove BK685 Rev 11 UL 1482-11 or ULC S627-00 July 2022...
Page 253
Install and operate this stove only in accordance with these instruction Applicable standards: UL 1482-11, ULC S627-00 This manual describes the installation and operation of the Arada, Farringdon 16 catalytic equipped wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2020.
Page 254
Contents Page No. Page No. INTRODUCTION SERVICE & MAINTENANCE Warning Notice Maintenance Safety Notices Cleaning The Principle Of The Stove Chimney Sweeping Check List Door Glass Data Label Plate A Outer Finish Data Label Plate B (Common) Fire Door Rope Replacement Technical data Fire Door Glass Replacement 24-25...
Page 255
DO NOT CONNECT THIS STOVE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE Installation of wood burning stoves must be safe and legal. The Farringdon 16 is designed for installation in main living areas of your home only. If your Farringdon stove is not installed correctly, it may cause a house fire.
When lifting always keep your back straight, Grate Bars bend your legs not your back The Farringdon 16 wood stove is fitted with a Avoid twisting at the waist. It is better to riddling grate system to support the fuel above reposition your feet.
CHECK LIST Inside the appliance body you should find the following: Part Description & Visual Aid (not to scale) Farringdon 16 1. Fuel Retainer 2. Throat Plate 3. Ash Pan 4. Throat Plate Insulation Blanket 5. Instruction Manual Arada Farringdon Stoves...
Page 258
CHECK LIST Inside the appliance you should find the following : Description & Visual Aid (not to scale) Farringdon 16 6. Back Side Liners 7. Front Side Liners 8. Rear Liner 9. Grate Bars 10. Stove Mitten ( Hot Glove) 11.
WARNINGS - ATTENTION Do NOT burn with the grate system removed Model Name, Modèle Farringdon 16 Catalyst Stove Ne pas utiliser sans la grille Tested To, Mis à l’épreuve selon la norme:- Do NOT overfire, If the chimney connector glows you are overfiring. (See Manual) UL1482-11, ULC S627-00 Ne pas surchauffer.
Page 260
U.S ENVIROMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate emission stand- Model Name, Modèle Farringdon 16 Catalyst Stove ards using crib wood per EPA Method 28R at 1.5 g/hr. This wood heater needs periodic inspection and repair for proper opera- Tested To, Mis à...
TECHNICAL DATA TECHNICAL DATA Farringdon 16 Maximum / Nominal Heat Output Kw Mean Flue Gas Temperature °C Height mm/inch 696/27.4 (Canopy To Base Feet) Width mm/inch 615/24.2 (Across Canopy) Depth mm/inch (Rear Heat Shield To Handle Boss—Handle 509/20 Removed )
Fire proof board spaced 13mm (0.5”) off the sur- ASBESTOS face with strips of non combustible material. Make All Arada stoves contain no asbestos in their man- sure that there is a gap between an ufacture or construction. If there is a possibility of...
INSTALLATION FITTING THE FLUE OUTLET AND FLUES AND CHIMNEYS HOT PLATE (Where Provided) The flue draw is critical on any installation and should be checked to ensure that it matches what Note: is specified. If it is higher than recommended, Not applicable for units supplied with a fixed provision must be made to correct the over draw.
Page 264
INSTALLATION If the stove appears to be working hard but produc- The flue and chimney installation must be carefully es very little output to the room it is likely that ex- checked by a competent person before fitting the cess draw is present in the chimney, and that heat stove to ensure it is suitable and will work safely.
Page 265
INSTALLATION Typical Factory built chimney installation in a single family residence General. Factory built chimneys and chimney units must be installed in accordance with the temperature and pressure conditions detailed in the manufacturers instructions. Temperature and pressure limits. Flue gas temperature and static pressure within the chimney must not exceed the limits used during listing tests Arada Farringdon Stoves...
Page 266
INSTALLATION Typical Metal Insulated Chimney System Installed To The Chimney Manufactures Instructions A HT type factory-built chimney approved UL103 or ULC 629 with 6 inches diameter (15.24 cm) A code-approved masonry chimney with a flue liner with a 6 inches diameter (15.24cm) PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES...
Page 267
INSTALLATION Masonry Chimney High Temperature prefabricated chimney cap High Temperature top plate Insulated High Temperature 6'' (150mm) diameter Flue liner, rigid or flexible. Minimum 16 feet high. (4.8 metres) Connector, rigid or flexible (between flue collar of stove and flue liner) of insert and flue liner) Sample installation into existing chimney.
Page 268
INSTALLATION Floor Protection The stove must be installed on a non-combustible material plate to protect the floor and possible fire caused by Ejection of sparks and hot ashes when the stove door is opened for refuelling etc. Radiated heat caused by stove over firing ...
Page 269
INSTALLATION Stove clearances on floor protection plate The floor protection plate must be of Non-Combustible Material Minimum dimensions listed may be increased C (USA) D (Canada) 203mm 203mm 406mm 458mm 8ins. 8ins. 16ins. 18ins. Floor Protection material R Values R Value 1.49 Thermal protection of is required 16 inches (406mm) in front of the stove when installed directly onto the floor or a step lower than 7 inches (178mm) See...
Page 270
INSTALLATION Stove clearances to combustible material. Minimum dimensions listed may be increased. Clearances may only be reduced by means approved by the regulatory authority. Straight Installation clearances Corner Installation clearances Standard Rear Heat shield and Single Wall flue pipe 685mm 457mm 432mm 356mm...
INSTALLATION Overall View Of Liners & Throat Plate Assembly FIREBOX LINER PANELS Throat plate sat correctly on air tube and rear air bar. The Arada Farringdon stove uses firebox liner Note: Insulation panels to the sides and back. The throat plate sits blanket not shown on top of the perforated air tube at the front and into two slots in the rear air bar.
INSTALLATION Catalyst Replacement The catalyst in your Farringdon 16 wood stove should be replaced after approximately 12000 hours of burning, or if you notice a darkening of the smoke omitted from your chimney. The catalyst should be replaced every 5 to 6 years irrespective of hours burned.
The following details must be checked and completed in full by the installer at the time of installation. Please answer all questions as fully as possible. Arada stoves cannot be held responsible for the chimney or installation. Arada Farringdon Stoves...
SERVICE & MAINTENANCE MAINTENANCE The whole flue way including the outlet must be swept at least twice per burning season. It is It is important that your appliance is regularly important that the flue ways, flue pipe and chimney serviced in accordance with these instructions. be cleaned prior to lighting the fire after a prolonged shut down period.
SERVICE & MAINTENANCE FIRE DOOR ROPE FIRE DOOR GLASS REPLACEMENT REPLACEMENT Periodically, visually check over the fire door rope seal for any damage, cuts or tears and any In the event of the door glass being broken it can detached sections. It is important to maintain these easily be replaced.
Page 276
SERVICE & MAINTENANCE Please Note: This should be carried out when the stove is cold and unlit. Fig. 10. Positioning The Glass Fig. 11. Tightening The Glass Clip The images used on pages 24 and 25 illustrating the door rope and glass replacement are generic images and may differ from the stove you have, but the procedure is identical.
SERVICE & MAINTENANCE Service Record Date of Visit Company Work Carried Out Signature Should you have any questions about your Arada Farringdon stove that have not been covered in this manual please contact your Arada dealer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits so they can complete the service record chart.
ALWAYS WEAR SUITABLE PROTECTIVE FIRE GLOVES WHEN REFUELLING YOUR STOVE. highly toxic Monoxide, a gas. DO NOT OPERATE THE STOVE WITH CRACKED OR BROKEN DOOR GLASS. The Farringdon 16 is NOT designed to burn any type of coal Arada Farringdon Stoves...
OPERATING INSTRUCTIONS BURNING WOOD Please Note : To avoid chimney problems your appliance should not be burnt at a reduced burn Set the fire by using rolled up newspaper and rate without a period of fast burning. place a layer of dry kindling wood on top of this. Smoke Detectors: ...
OPERATING INSTRUCTIONS OVER FIRING & CHIMNEY FIRES Ash Disposal. DO NOT OVER FIRE THIS HEATER. Using Ashes should be placed in a metal container with a flammable liquids or too much wood or firing the tight fitting lid. The closed container of ashes stove at maximum for prolonged periods or should be placed on a non-combustible floor or on operating with fire doors open may result in...
OPERATING INSTRUCTIONS The exact position of the air control will vary AIR INLET CONTROL according to installation factors and some experimentation will be required to acquire the The Arada Farringdon 16kw stove air inlet control. optimum position for burning The primary air control (Left) should be used to The primary air inlet provides the main air supply to the fuel and the airwash system through the control slider vary the burn rate.
OPERATING INSTRUCTIONS Catalyst Stove thermometer The stove thermometer indicates when the The Arada Farringdon 16kw stove is fitted with a ceramic stove is at the correct temperature to close the catalyst to aid clean burning. by-pass door for normal running, and re-open The catalyst should be inspected for damage annually and for re-fueling and/or lighting, See Fig 16.
OPERATING INSTRUCTIONS MAIN FIRE DOOR HANDLE A stove mitten is supplied with your Arada Farringdon stove, this is provided for the operation of the fire door handle whilst the stove is in use. Care must be taken when opening and closing the fire door as any surrounding areas of the stove will be very hot.
The warranty policy applies to wood-burning products identified by the Arada and Aarrow trade names only. Arada Stoves warrants that each stove body will be free of material defect for a period of 10-years from the date of original purchase. If a product is proved to contain a defective component, Arada Stoves will, at its sole discretion authorise repair or replace the defective part at Arada Stoves expense.
Page 286
Glass is warranted against damage resulting from thermal shock only, for a 12 month period from date of purchase. In no event shall Arada Stoves be liable for incidental or consequential damages, injury to persons, property, or any other consequential loss.
Arada, disponible Combustible: chez votre revendeur agrée. Adresses et détails sont disponibles sur www.aradastoves.com. Le Farringdon 16 est conçu pour ne brûler que du bois. Utiliser du bois non-traité et séché avec un Checking your combustor: pourcentage d’humidité inférieur à 20%.
Page 288
A USER QUICK REFERENCE GUIDE Cont.:- Replacement: Remplacement : If the stove is operated in accordance with the Si le poêle est utilisé conformément aux instructions instructions within this manual you combustor dans cette notice, votre chambre de combustion should last 5 to 6 years, (or approximately 12000 doit pouvoir être utilisée pendant 5 ou 6 ans.
Page 289
CATALYST ADDITIONAL INFORMATION It is important to periodically monitor the operation of the catalytic combustor to ensure that it is functioning properly and to determine when it needs to be replaced. A non-functioning combustor will result in a loss of heating efficiency, and an increase in creosote and emissions. Following is a list of items that should be checked on a periodic basis: Combustors should be visually inspected at least three times during the heating season to determine if physical degradation has occurred.
Final Factory Check list Stove Model …………….……………… Serial No. ………………………………. Quality / Finish I’ve checked it Grate bars (14) and its O.K ! Fuel Retainer Firebox Liners (8) Throat Plate Throat Plate Insulation Blanket Assembled By………………………. Door / Riddle Handle Ash Pan Checked by…………………………..
Page 292
Manufactured by, Fabriqué par Arada Ltd Certified to comply with 2020 particulate emission standards using crib wood per EPA Method Model Name, Modèle Axminster, Devon Farringdon 16 Catalyst Stove 28R at 1.5 g/hr. United Kingdom EX13 5HU Ne pas utiliser dans les maisons mobiles Tested To, Mis à...