Summary of Contents for PDX.GOLD VaporSmartz iQ 150

  • Page 1 @pdx.gold contact@pdx.gold 503.783.6550 www.pdx.gold 20209 SW 95th Ave. Tualatin, OR 97062...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WELCOME PRECAUTIONS & SAFETY SPECIFICATIONS INSPECTION & RECEIVING SYMBOLS & WARNINGS PRODUCT OVERVIEW EVAPORATION PRESSURES THE FILTER DRYER INSTALLATION OPERATION MAINTENANCE CERTIFICATION WARRANTY...
  • Page 3: Welcome

    WELCOME Hello and welcome to the PDX.GOLD family. We understand there are a lot of choices in the marketplace for botanical recovery systems, so we are delighted you have chosen to invest in us. We designed our Solvent Transfer and Recovery pumps with you in mind and sincerely hope you notice the difference in quality and safety standards that set us apart from our competitors.
  • Page 4: Precautions & Safety

    PRECAUTIONS & SAFETY WARNING: THE VaporSMARTZ iQ150 IS DESIGNED FOR HIGH VOLUME RECOVERY AT PRESSURES BELOW 150PSI (VaporSMARTZiQ120 BELOW 120PSI). IT HAS SAFETY PRESSURE SWITCHES TO LIMIT THE SYSTEM PRESSURE TO 150 / 120 PSI. DEADHEADING YOUR PUMP FOR ANY SIGNIFICANT TIME AGAINST PRESSURES AT OR ABOVE 150PSI (120PSI for iQ120) GENERATES EXCESSIVE HEAT AND WILL DAMAGE THE PUMP OVER TIME.
  • Page 5: Specifications

    SPECIFICATIONS General Specifications Maximum Output Pressure (VaporSmartz iQ150) 150 PSI Maximum Output Pressure (VaporSmartz iQ120) 120 PSI Motor Size (VaporSmartz iQ150) 2 Hp Motor Size (VaporSmartz iQ120) 1 HP Noise Level 78 dB Free Air Displacement (VaporSmartz iQ150) 6.5 CFM Free Air Displacement (VaporSmartz iQ120) 5.2 CFM Pressure Shut off Valve (VaporSmartz iQ150)
  • Page 6: Inspection & Receiving

    Once visual inspection has verified no obvious damage has occurred during shipment, carefully uncrate the unit. If the unit looks damaged, stop at once and call PDX.GOLD Customer Service. Remove the unit from the pallet. Use two people to lift the unit off the pallet, then roll it into position and lock wheels in place.
  • Page 7: Symbols & Warnings

    SYMBOLS & WARNINGS This recovery system pumps Butane and Propane, both flammable gases. This machine must be kept in an explosion- proof lab that meets environmental, safety and other regulations. Explosion Hazard: NO smoking, NO open flames, NO sparks Do not use VaporSmartz iQ150 / VaporSmartz iQ120 without proper ventilation.
  • Page 8: Product Overview

    Power Cord Theory of Operation The PDX.GOLD VaporSmartz iQ150 / VaporSmartz iQ120 is a single-switch operation. This solvent transfer and recovery system transfers solvent gas within a closed loop extractor and returns it, under pressure (up to 150 psi / 120psi), to a recovery tank for isolation and storage. The...
  • Page 9 PRODUCT OVERVIEW Component Overview The main power switch is pictured here in the OFF position. When the switch is in the “ON” position, the pump will be fully engaged and operational. There are no other switches or valves to manage. The Input Connection is located on the back of the unit labeled “input”.
  • Page 10: Evaporation Pressures

    EVAPORATION PRESSURES Vapor Pressure (psig) Propane MIXTURE Butane ˚F 11.5 17.5 24.5 20.5 12.3 17.8 10.2 36.5 24.5 15.4 32.4 21.5 28.5 36.5 11.5...
  • Page 11: The Filter Dryer

    The VaporSmartz series are high-performance solvent transfer and recovery pumps and may overwhelm many types of filter dryers. PDX.Gold has designed our own filter dryer, the CycloneDry, which may be configured for ANY size extraction system. CycloneDry is a modular system - simply daisy-chain any number of CycloneDrys to your recovery system (via stainless steel braided hoses) to keep up with your level of processing.
  • Page 12: Installation

    INSTALLATION Lifting & Handling The VaporSmartz iQ150 / VaporSmartz iQ120 is a precision machine that should be handled with care and respect. Except for initial removal from the pallet, do not lift the VaporSmartz iQ150 / VaporSmartz iQ120. Utilize the installed casters to roll the unit into place. *** Highly recommended that you use two people to lift from pallet *** Lock the casters once in place.
  • Page 13 INSTALLATION The VaporSmartz iQ150 / VaporSmartz iQ120 does not have any manually adjustable valves. Use the valves on your extractor to control the flow of gas. Connecting to the Extractor Follow all instructions in this manual closely. Follow all instructions associated with your closed loop extractor closely. Close the Input and Output Valves on the Extractor.
  • Page 14: Operation

    OPERATION The following operation instructions assume the unit has been properly installed in accordance with all applicable municipal safety, regulatory and legal compliance. Do not proceed until proper installation has been completed. Pre-Flight Check Verify all fittings and connections between your extractor and VaporSmartz have been tightened appropriately.
  • Page 15 Reconnect the unit to the power supply. Turn the control switch to “ON” and observe unit. Continuing auto shut-off events NOT associated with pressures near the operating limits may indicate pump contamination and / or motor damage. Contact PDX.GOLD for assistance.
  • Page 16: Maintenance

    MAINTENANCE WARNING: Disconnect the unit from power supply prior to doing any maintenance on the VaporSmartz. General Maintenance When cared for and operated properly according to this manual, the unit is essentially maintenance free and will provide years of dependable service. THE MOST IMPORTANT THING THE USER CAN DO TO REALIZE A LONG, TROUBLEFREE PUMP LIFE IS TO TRANSFER CLEAN AND DRY SOLVENT.
  • Page 17: Certification

    3PCertz attesting to the fact your machine has been reviewed and held to the utmost standards in cannabis extraction technology. PDX.GOLD and 3PCertz offer certification for 14 states and the District of Columbia in the United States. If your location is not listed, give us a call and we can review getting your location added...
  • Page 18 CERTIFICATION Electrical Part Manufacturer Description Motor Leeson NEMA 7, 2 HP, 1725 rpm. VaporSmartz iQ150 Motor Leeson NEMA 7, 1 HP, 1725 rpm. VaporSmartz iQ120 Switch Enclosure Sprecher-Schuh NEMA 7 switch housing, includes motor controller and shunt circuit. Pressure Switches Ashcroft NEMA 7, 1/4”...
  • Page 19: Warranty

    – PDX.GOLD warrants products sold against defects in material or workmanship as follows: PDX.GOLD, at its option, unless otherwise agreed, will replace or repair any defective product unit or defective part of the product unit at no charge, provided that: 1.