Advertisement

Quick Links

contact@pdx.gold
503.783.6550
@pdx.gold
www.pdx.gold
20209 SW 95th Ave. Tualatin, OR 97062

Advertisement

Table of Contents
loading

Summary of Contents for PDX.GOLD STAR-150

  • Page 1 503.783.6550 @pdx.gold www.pdx.gold 20209 SW 95th Ave. Tualatin, OR 97062...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WELCOME PRECAUTIONS & SAFETY SPECIFICATIONS INSPECTION & RECEIVING SYMBOLS & WARNINGS PRODUCT OVERVIEW EVAPORATION PRESSURES FILTER DRYER INSTALLATION OPERATION MAINTENANCE CERTIFICATION WARRANTY...
  • Page 3: Welcome

    WELCOME Hello and welcome to the PDX.GOLD family. We understand there are a lot of choices in the marketplace for botanical recovery systems, so we are delighted you have chosen to invest in us. We designed our Solvent Transfer and Recovery pumps with you in mind and sincerely hope you notice the difference in quality and safety standards that set us apart from our competitors.
  • Page 4: Precautions & Safety

    PRECAUTIONS & SAFETY WARNING: THE STAR-150 IS DESIGNED FOR HIGH VOLUME RECOVERY AT PRESSURES BELOW 150PSI. IT HAS SAFETY PRESSURE VALVING TO LIMIT THE SYSTEM PRESSURE TO 150 PSI. DEADHEADING YOUR PUMP FOR ANY SIGNIFICANT TIME AGAINST PRESSURES AT OR ABOVE 150PSI GENERATES EXCESSIVE HEAT AND WILL DAMAGE THE PUMP OVER TIME.
  • Page 5: Specifications

    SPECIFICATIONS Specifications Maximum Output Pressure 150 PSI Motor Size 2 HP (single phase / 3-phase) 6.18 In. Pump Displacement Noise Level 78 dB Free Air Displacement 20 lbs/hr Maximum Recovery Rate 15 CFM Pressure Relief Valve 150 PSI Applicable Media Butane, Propane, Propane / Blends.
  • Page 6: Inspection & Receiving

    Once visual inspection has verified no obvious damage has occurred during shipment, carefully uncrate the unit. If the unit looks damaged, stop at once and call PDX.GOLD Customer Service. Remove the unit from the pallet. Use two people to lift the unit off the pallet, and position near the extractor.
  • Page 7: Symbols & Warnings

    Protective clothing: Fire resistant coveralls or jumpsuit is highly recommended. Although working with a CLE (closed loop extractor) drastically cuts down the risk of an explosive environment, we strongly suggest anyone operating the STAR-150 wear fire resistant clothing due to the flammable nature of butane and propane.
  • Page 8: Product Overview

    This solvent transfer and recovery system transfers solvent gas within a closed loop extractor and returns it, under pressure (up to 150 psi), to a recovery tank for isolation and storage. The STAR-150 requires 230v power which must be connected to a power source by a licensed electrician. The internal components are all food grade and are comprised of aluminum, stainless steel, iron, and Viton and Buna-N elastomers.
  • Page 9 PRODUCT OVERVIEW Component Overview When viewing the top of the STAR-150, the input connection is located nearest to the belt guard. The unit is shipped with a tag identifying this “INPUT”. The input connection is ½” tube fitting (Swagelock compatible).
  • Page 10: Evaporation Pressures

    EVAPORATION PRESSURES Vapor Pressure (psig) Propane MIXTURE Butane º 11.5 17.5 24.5 20.5 12.3 17.8 10.2 36.5 24.5 15.4 32.4 21.5 28.5 36.5 11.5...
  • Page 11: Filter Dryer

    / solvent filter-dryer in the system before the input of the pump. The STAR-150 is a high-performance solvent transfer and recovery pump and may overwhelm many types of filter-dryers. PDX.Gold has designed our own filter dryer, the CycloneDry, which may be configured for ANY size extraction system.
  • Page 12: Installation

    Protect your pump from air-borne dust and debris that can impede ventilation. Installation Location Requirements The STAR-150 is intended to be used indoors on a flat surface. The laboratory environment should comply with all local and state regulations and safety standards. Prior to installation, consider the power source, location of other equipment and operator comfort and efficiency.
  • Page 13 STAR-150. Power Source Continued STAR-150 may be fitted with a NEMA 7 plug, connected to a NEMA 7 receptacle and switch that has been installed according to your state / county safety regulations within your extraction room.
  • Page 14: Operation

    VALVES CLOSED. Power-Up Once you have verified the installation and checked out the system, it is time to power up. Depending on your installation, simply plug in your STAR-150 to its designated outlet or activate the power switch if installed. Power-Down Close the output valve on the extractor.
  • Page 15: Maintenance

    MAINTENANCE WARNING: Disconnect the unit from power supply prior to doing any maintenance on the STAR-150. General Maintenance When cared for and operated properly according to this manual, the unit is essentially maintenance free and will provide years of dependable service.
  • Page 16: Certification

    If you have purchased a certified unit, your STAR-150 will have a serial tag provided by 3PCertz attesting to the fact your machine has been reviewed and held to the utmost standards in cannabis extraction technology.
  • Page 17 CERTIFICATION Electrical Part Manufacturer Description Motor Leeson NEMA 7, 2 HP, single phase, 1725 rpm. standard Marathon NEMA 7, 2 HP, 3-phase, 1725 rpm. Motor optional Fittings & Hoses Part Manufacturer Description Fittings Swagelok / SSP ¼” & ½” 2600 psi working pressure dual ferrule fittings.
  • Page 18: Warranty

    – PDX.GOLD warrants products sold against defects in material or workmanship as follows: PDX.GOLD, at its option, unless otherwise agreed, will replace or repair any defective product unit or defective part of the product unit at no charge, provided that: 1.