1. List of contents List of contents ......................2 Information for your safety..................... 3 Marking of safety instructions in the operating manual ..........3 Variants of control heads ASi-Bus ES/ABSL..............4 Double seat valve (pneum. Lifting valve) ............4 Single seat valve (pneum. Lifting valve).............. 4 Butterfly valve / Ball valve (pneum.
2. Information for your safety We are pleased that you have decided for a high-class KIESELMANN product. With correct application and adequate maintenance, our products provide long time and reliable operation. Before installation and initiation, please carefully read this instruction manual and the security advices contained in it.
5. Safety instructions 5.1 Field of application The control heads are used to pilot valves of production systems of the beverage and foodstuff industry, pharmaceutical industry, bio-technology, and chemical industry. They contain the complete actuator, sensory, and electronic technology for connection and integration to up-dated and efficient control systems.
ES way. Encoding takes place from the Kieselmann society. The counter is sealed after the choice. A suitable mark of the type of the manage- ment is indicated on the frame.
= Butterfly / Ball valve air open/air closed LED 5 Red Valve closed = Butterfly / Ball valve air closed/spring open = reserved KIESELMANN LED 6 Green Valve open = reserved KIESELMANN LED 5 / LED 6 Flashing alternately indicates...
11.4 Electrical connection design of control head ASi-Bus ES/ABSL = Valve selector switch for valve type see Tab.1 = Selector switch: Position 1 Standard Position 2 ES-mode = Plug electrical connection for solenoid valve (MV) P1 = JTAG Interface (Onbord programming) P2 = Plug ASi-Bus 24V (+) braun/brown...
12. Position control and position indication 12.1 Lifting valve The repeat signal message ‘valve opened‘ or ‘valve closed‘ occurs contactless through the magnet field of the pulse initiator‘s toric magnets at coverage of the Hall sensors on the board. NOTE The installation position of the pulse generator is characterized by a marking in the spindle.
12.2 Rotary valve The stop position feedback signal valve "OPEN" or "CLOSED" is carried out contactlessly over the magnetic field of the bar magnets in the pulse generator during overlap with the hall sensors on the printed circuit board. Valve Position Indicator ➣...
13.2 Valve piloting - Lifting valve Valve selector Valve function Solenoid valve (MV) switch position (D) air open / spring closed MV 1 air closed / spring open MV 1 air open / air closed MV1 / MV3 Bit-assignment Valve function Solenoid valve Pneum.
13.3 Valve piloting - Rotary valve Valve selector Valve function Solenoid valve (MV) switch position (D) air open / spring closed MV 2 air closed / spring open MV 2 air open / air closed MV2 / MV3 Bit-assignment Valve function Solenoid valve Pneumatic INPUT...
14. Disassembly and assembly 14.1 Disassembly • Disconnect the compressed-air pipe, control air pipe and elec- trical lines from the control head. • Unlock the cab (21) by rotary movement and lift it (bayonet socket). 1) - when replacing the valve actuator •...
16. Technical data Bus-system: Control of valve position Principle of effectiveness: 1 - 62 AB-Slave Function of evaluation: -10°C to +50°C Range of address: II (Control head with cap transparent) I (Control head with cap stainless steel) Operating temperature: IP 67 (Control head with cap transparent) IP 65 (Control head with cap stainless steel) Appliance classes: 22 - 30V DC...
Need help?
Do you have a question about the ASi-Bus ES/ABSL 5630 010-000 Series and is the answer not in the manual?
Questions and answers