TESTING AND ADJUSTING
ADJUSTING
Adjusting LS valve
a If the LS differential pressure is abnormal, adjust
LS valve (4) according to the procedure shown
below.
a The figure shows the hydraulic pump seen from
the front side of the machine.
1. Loosen hose sleeve nut (4).
2. Fixing plug (5), loosen locknut (6).
3. Turn plug (5) to adjust the differential pressure.
a If the plug is
turned to the right, the differential pres-
sure rises.
turned to the left, the differential pressure
lowers.
a Quantity of adjustment (LS differential pres-
sure) per turn of plug:
a Tighten the hose sleeve nut (4) temporarily
and turn the plug, while checking the LS dif-
ferential pressure.
3 Locknut: 98 – 122.5 Nm {10 – 12.5 kgm}
4. Fixing plug (5), tighten locknut (6).
5. Tighten hose sleeve nut (4).
20-132
(1)
2
1,304 kPa {13.3 kg/cm
}
TESTING AND ADJUSTING OIL PRESSURE
IN PUMP LS CONTROL CIRCUIT
6. After finishing adjustment, check that the pres-
sure is normal according to the above described
procedure.
PC130-7