  • Page 1 5.5 cu.ft. Undercounter Refrigerator Premier Plus Series Installation and Operation 328277H09 • Revision A • April 2018...
  • Page 2 Cardinal Health makes no representations or warranties with respect to this manual. In no event shall Cardinal Health be held liable for any damages, direct or incidental, arising from or related to the use of this manual.
  • Page 3: Table Of Contents

    Contents Product Specifications ........1 Models ..............1 General Specifications and Features......1 Physical Dimensions..........2 Agency Approvals ............ 2 Data Monitoring and Lodging ........2 Environmental Operating Conditions......3 ENERGY STAR® Certification ........3 Safety Precautions ..........4 Wiring Diagram ..........6 Unpacking the Premier Plus Refrigerator ....7 Inspecting for Damage ..........
  • Page 4 Preset Alarms/Alerts..........10 Set Point Temperature ..........11 Loading Products for the First Time......11 Tips for Managing Door Openings ......11 Automatic Defrost Cycles ......... 11 Getting To Know Your Product ......12 Product Exterior - Front..........12 Product Exterior - Rear..........13 Product Interior ............
  • Page 5: Product Specifications

    Product Specifications Models Model Description CA505SA Premier Plus Under-Counter Solid Door Refrigerator, NEMA 5-15P CA505GA Premier Plus Under-Counter Glass Door Refrigerator, NEMA 5-15P CA505SD Premier Plus Under-Counter Solid Door Refrigerator, NEMA 6-15P CA505GD Premier Plus Under-Counter Glass Door Refrigerator, NEMA 6-15P General Specifications and Features Model Style...
  • Page 6: Physical Dimensions

    Physical Dimensions Weight Solid Door unit: 125 lbs./56.8 Kg Glass Door unit: 135 lbs./61.5 Kg Outer Dimensions 600 mm W x 686 mm D x 813 mm H 23.6" W x 27" D x 32" H Internal Dimensions 496 mm W x 521 mm D x 585 mm H 19.5"...
  • Page 7: Environmental Operating Conditions

    Environmental Operating Conditions Operating ambient temperature 15°C–32°C Operating Humidity No more than 65% RH non-condensing. Product approved for indoor use only. Warranty 2 years on all parts and labor, 7 years on thermoelectric heat pumps part Altitude For Operation of up to 2,000 m Pollution Degree Ingress Protection IP3X...
  • Page 8: Safety Precautions

    Safety Precautions All electrical appliances present some risk of injury. Your Before installing, using or maintaining this product, be sure to Premier Plus refrigerator is designed to meet safety read the manual and product warning labels carefully. Failure standards. to follow these instructions may cause the product to malfunction, which could result in injury or damage.
  • Page 9 WARNING: Hazardous voltages are present: To reduce the risk of electric shock DO NOT remove the rear cover on this product. There are no user serviceable parts inside. Please refer service to qualified personnel. CAUTION: Cells/batteries shall be tested and pass applicable regulations based on type and use such as: •...
  • Page 10: Wiring Diagram

    Wiring Diagram Figure 1. Wiring diagram for Premier Plus 5.5 cu.ft. Undercounter Refrigerator Wiring Diagram 5.5 cu.ft. Undercounter Refrigerator...
  • Page 11: Unpacking The Premier Plus Refrigerator

    Unpacking the Premier Plus Refrigerator Inspecting for Damage Identifying all Parts Please take a moment to inspect your new refrigerator for damages that may have occurred during shipping. For any damage done to the refrigerator, please contact the delivery carrier directly. Do not call the Premier Plus service line to report shipping damages.
  • Page 12: Installation

    Installation Leveling The fans on your product will run at intervals of Adjust the leveling feet located underneath the refrigerator by variable speeds and may turn off completely. turning clockwise to extend the feet, counter clockwise to They do not run constantly. If the fans run shorten them.
  • Page 13: Uninterruptable Power Supply (Ups)

    Note: The electrical safety of this product may become impaired if you chooses to disregard this power safety steps listed above. Be careful not to plug into a wall outlet controlled by a wall switch to avoid accidentally switching off the refrigerator.
  • Page 14: Operation

    Operation 2. The sample bottle is securely mounted in the clip LED Indicator provided. 3. The level of the propylene glycol in the bottle is full. When you turn on your refrigerator, verify that the LED indicator is working. The LED indicator appears on the front In the event that the bottle has broken during shipping, control panel next to the upper corner of the display.
  • Page 15: Set Point Temperature

    Set Point Temperature Tips for Managing Door Openings When you first turn on the unit, the fan will run and the refrigerator will work to reach the default set point temperature. Once set point is reached, the fan speed will When a refrigerator door is opened, warmer ambient air reduce to conserve energy.
  • Page 16: Getting To Know Your Product

    Getting To Know Your Product inserting the USB drive (not included) and looking for the USB Product Exterior - Front icon in the icon bar at the top of the LCD display. Data Monitoring Backup Battery Activating the Battery: The included battery is shipped with a protective tab so that its power doesn’t drain.
  • Page 17: Product Exterior - Rear

    Door Lock Product Exterior - Rear The 5.5 cu.ft. refrigerator door locking mechanism is password protected. A user, sub-admin or admin password or PIN is required to unlock the refrigerator and gain access to stored product. A Universal Password/Pin is provided with the unit and must be entered upon the first/initial login.
  • Page 18: Product Interior

    Product Interior Interior Components • Glycol temperature sensor port and sample bottle • Air temperature sensors (2) • External pass-through port • Adjustable shelving • Adjustable LED lighting Adjustable Shelving Your Premier Plus undercounter refrigerator is shipped with wire ties holding the shelves in place. Remove the wire ties before using the refrigerator.
  • Page 19: Navigating Premier Plus 5.5 Cu.ft. Refrigerator Controls

    Navigating Premier Plus 5.5 cu.ft. Refrigerator Controls System Icons System Alerts Alert Icons Air Temperature Range Glycol Temperature Range Door Ajar Loss of Power Battery Low Memory Low System Prompts System Error System Alert Value Alarm Factory Setting Icon Temperature Range min 2°C - max 8°C Alarm Door Ajar Alarm...
  • Page 20: Reading The Lcd (Temperature) Display

    Reading the LCD (Temperature) Display The Temperature Display is preset to show the Glycol Sensor reading, measured in Celsius and to the tenth of a degree. The current temperature, date and time are displayed in every screen in the graphic user interface with the exception of the screen where an administrator, sub-administrator or user enters their password to unlock the door.
  • Page 21 Alarms Data Log Data log is part of the local temperature monitoring accessory Active Alarms and can be added to any Premier Plus refrigerator. The Active Alarms screen displays a list of active alarms and is Min/Max Temperatures one of the ways that an alarm can be cleared. Tap Active Alarms to access the Active Alarms display.
  • Page 22 Reviewing / Adjusting Data Log If the user sees the Error saving Data Log screen, there is a compatibility issue with the USB drive OR the USB drive may Settings have other files on the USB drive that interfere with the download.
  • Page 23 Settings Defrost Temperature Set Point Selecting Defrost from the Settings menu will prompt the user Temperature Set Point is where the user selects the desired to set-up and run a manual defrost. The Defrost screen also unit set point. Using the up and down arrows allow the user to shows when the unit ran a defrost function last.
  • Page 24 Lighting Firmware Select Lighting to adjust the brightness level, lighting on with door open and the duration of the lighting to remain on after closing the door. System Information Selecting System Information from the Settings menu enables the user to view the key system information on the unit such as the product Serial Number and battery health.
  • Page 25 When Calibrating, it is recommended to Calibrate the Control sensor first and allow time for the system to equilibrate before making any adjustments to Glycol. An example of calculating an offset value: Your NIST certified temperature reading is 3.7°C, the unit reading is 4.2°C, the offset would be -0.5°C. 5.5 cu.ft.
  • Page 26: Periodic Product Maintenance

    Periodic Product Maintenance Use of cloth to wipe interior: With cold wall refrigerators, condensation may form on the interior of the cabinet and may require periodic wipe-down with an absorbent cloth. Suitable products for cleaning interior/exterior: The unit may be cleaned, when needed, using a mild detergent and a damp cloth.
  • Page 27: Frequently Asked Questions

    What is the product warranty? performance of the refrigerator. We recommend adequate Cardinal Health offers a 2-year product warranty on parts and ventilation at the front of the cabinet to dissipate heat outside labor.
  • Page 28: Troubleshooting

    Download data and clear the data log. If light remains red Data logging error but unit is operating normal there may be another issue with the internal data log; download data and contact Cardinal Health Customer Care. Flashing Red Download data and clear the data log. If continues flashing Data logging error during power failure mode red, possibly there’s an issue with the backup battery power...
  • Page 29 Troubleshooting Problems Customer Resolution I hear more fan noise than normal Has the temperature risen recently? Is the front free & clear for proper ventilation? If you've recently held the door open for an extended period of time or you put warmer product in the refrigerator then the unit is likely recovering to its set point temperature.
  • Page 30 Troubleshooting Problems Customer Resolution I got a system error code Call Customer Care for assistance, 866-984-3766 Did you remove the red tab to activate the battery contacts? If the battery strength is low, it needs to be replaced. Why does my screen image invert? In the case of a power failure, system operates on Battery Mode: The LCD will remain functional through the use of a back-up...
  • Page 31: Product Warranty And Service

    Cardinal Health are not covered by this warranty. 4. Cardinal Health may require any parts covered under this warranty be returned to Cardinal Health freight prepaid, and this warranty shall apply only if Cardinal Health verifies the applicable defect upon examination.
  • Page 32 Important For your future reference and when contacting the factory, please have the following information readily available: Model Number: Serial Number: Date Purchased: The above information can be found on the dataplate attached to the equipment. If available, please provide the date purchased, the source of purchase (manufacturer or specific agent/rep organiza- tion), and purchase order number.
  • Page 33 United States cardinalhealth.com Find out more at cardinalhealth.com © 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH and the Cardinal Health LOGO are trademarks of Cardinal Health and may be registered in the US and/or in other countries. 328277H09 0418...