Disposal And Warranty; Discharge Curves - Tecate TPLC Series User Manual

Table of Contents

Advertisement

shipping requirements. Hybrid capacitors are regulated for transportation according to UN
 
3508, we recommend that you consult your local logistics authority for specific requirements.
 

8. Disposal and Warranty:

federal and national requirements. In most jurisdictions the cell can be disposed of by
industrial waste organizations. You will need to insulate the terminals to avoid any short
 
circuit possibility. Our product warranty may be found under our standard Terms and
Conditions for sale. This product warranty and is limited to the actual product and does not
 
constitute any liability for damages that may be a direct result from improper use or defects
in our products.
 
9. Discharge Curves: Representative constant current discharge curves for select cells.
4
3.5
3
2.5
2
1.5
1
0.5
0
0
100
7520 Mission Valley Road ● San Diego, CA 92108-4400 ● USA ● Tel: 619.398.9700 ● Fax: 619.398.9777 ● www.tecategroup.com
9101840000.f.docx.INSERT DOC #DOCX
When disposing of the product comply with all local, regional,
 
TPLC‐3R8/30MR10X16
Discharge Curve @ 25
200
300
 
°
C
400
500
600
Sec
700
800
900
 
50 mA
100 mA
150 mA
200 mA
300 mA
500 mA
700 mA
1 Amp
1.5 Amp
2 Amp
PAGE 6

Advertisement

Table of Contents
loading

Table of Contents