INSTRUCTION SHEET
ESE REMOTE TESTER for RT models, (SIREMOTETESTER)

Description and Purpose

Remote detection of the operation status for Early Streamer Emission RT Terminal (ESE RT) models by luminous
information. Easily test the state of an nVent ERICO System 1000 Early Streamer Emission Terminal while on-site.

Instructions for Use

The SIREMOTETESTER works only in sunlight (minimum of 3300 lux of luminosity) and a minimum power load.
View the bottom of the device up to 100m away for a maximum of two minutes until LED light flashes, then proceed
according to the color indication.

Function of Indicators

1
3 4 5
2

Electrical Specifications

Self-powered with an included photovoltaic cell
Does not include a battery, increasing the device's lifespan
Tested with Impulse Current (I

Features

Waterproof: IP68
Dimensions: Length 80 mm, Depth 84 mm, Height 180 mm.
Weight: 1.25 Kg

Inspection Schedule Guidelines

To ensure proper maintenance, follow the required test schedule in section 8 of NFC 17-102 standard, on Table 7
(periodicity of inspection regarding the protection level).
Lightning Protection
Level
I and II
III and IV
NOTE:
Please adapt to the local regulations if more restrictive.
Electrical testing of the installation should be performed once a year.
TECHNICAL SUPPORT:
www.nVent.com
1.
Connection terminal for cables connecting to the ESE RT (ex. SI60I316RT).
2.
Conection to mast SIM28A2 or SIM28A2316.
3.
Red
LED (2 flashes at 1 second, every 2 minutes max) indicates:
ESE RT is out of service and needs to be replaced
4.
Green
LED (2 flashes at 1 second, every 2 minutes max) indicates:
ESE RT is operational
5.
Yellow
LED (2 flashes at 1 second, every 2 minutes max) indicates:
SIREMOTESTER operating problem is detected and requires attention or replacement*
*Note 1: Excludes charging issue or an insufficient charge level.
*Note 2: Immediately after assembly of the ESE RT and SIREMOTETESTER it will take up to 30 minutes
with sufficent sunlight for the tester to be operational, or 10 minutes with a high lumen flashlight.
*Note 3: A test cycle of the ESE RT is made every 3 hours after the SIREMOTETESTER is fully charged
and has sufficient sunlight.
Note 4: We recommend assembly 1 day before any job site installation, placing the assembly in sufficient
*
sunlight, so at least 1 test cycle can be completed.
) 100 kA, 10/350 µs.
imp
Visual
Complete
inspection
inspection
1 year
2 years
2 years
4 years
IP9021_A
Critical systems
In case of structures
complete inspection
with a risk of explosion
1 year
6 months
1 year
N/A
1 of 6
2022 nVent All Rights Reserved
Inspection after a
lightning event in
the structure
Complete
Visual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ESE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for nvent ESE

  • Page 1 10 minutes with a high lumen flashlight. *Note 3: A test cycle of the ESE RT is made every 3 hours after the SIREMOTETESTER is fully charged and has sufficient sunlight.
  • Page 2 TMCSS316 WARNING: 1. nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Inst ruction sheets are available at www.nVent.com and from your nVent customer service representative. 2. nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
  • Page 3 Description et objectif Détection à distance de l'état de fonctionnement des Paratonnerres à Dispositif d'Amorçage, (modèles RT) par information lumineuse. Vérifier facilement à une distance de 100 m l'état du PDA RT faisant partie du System 1000 nVent ERICO. Mode d'emploi Le SIREMOTETESTER fonctionne avec la lumière du soleil, un minimum de 3300 lux de luminosité...
  • Page 4 TMCSS316 WARNING: 1. nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Inst ruction sheets are available at www.nVent.com and from your nVent customer service representative. 2. nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that excee ds specified load ratings.
  • Page 5 Descripción y objetivo Detección remota del estado de funcionamiento de Pararrayos con Dispositivo de Cebado (modelos RT) mediante información lumínica. Compruebe fácilmente el estado de un PDC nVent ERICO System 1000 RT desde 100 m. Modo de empleo El SIREMOTETESTER funciona con luz solar, brillo mínimo de 3300 lux y una carga eléctrica mínima. Mire la parte inferior del dispositivo desde una distancia de hasta 100 m durante un máximo de dos minutos hasta que la luz LED...
  • Page 6 TMCSS316 WARNING: 1. nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Instruction sheets are available at www.nVent.com and from your nVent customer service representative. 2. nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.

Table of Contents