6)
NOTICES
(1)
Charge the battery through removing the
battery connector and connecting the
charging connector of the stationary
charger to the battery connector.
(2)
Be sure to open the battery cover during
charging.
(3)
Check specific gravity and electrolyte level
once a week. Specific gravity at a
temperature of 20
C is as follows :
At charged(completion of charge) : 1.280
At discharged(Charging required) : 1.17
(4)
Check electrolyte level, and if it is
insufficient, refill distilled water to the
specified level.
Distilled water should be refilled to get the
red color ring the stopper or come the red
color float support out.
St
1,300
1,250
1,200
1,150
-10
Red color float support
Red color ring
Float
4-5
Charger
BATTERY CHARGER
BATTERY CHARGER MONITOR
AC IN
CHARGE LEVEL
FLOAT
EQUAL
END
ERROR
RESET
EQUAL S/W
MANUAL STOP
SWITCH
BP157OM21
Battery
cover
BP157OM22
S20
1,300
1,250
1,200
1,150
10 20 30 40 50
t( C)
BP157OM23
Normal level
BP157OM24