CopperOptics PairGain PG-FLEX PLUS PRL-770 List 2E Manual

Indoor remote terminal enclosure

Advertisement

Quick Links

PG-F
- F l
P G
M O
R E
R M
T E
P
G
AIR
AIN
E
S
NGINEERING
ERVICES
™950-779-115-020¨
S
ECTION
P
LUS
LEX
Indoor Remote Terminal
s
P l u
e x
Enclosure
T E
L
I N A
PRL-770 List 2E
PRL-779 List 1E
Part Number:
CLEI Code:
T
, I
ECHNOLOGIES
NC
T
ECHNICAL
950-779-115-02
150-1670-52
150-1679-51
S9MSBA0A
S9MSEH0A
.
P
RACTICE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PairGain PG-FLEX PLUS PRL-770 List 2E and is the answer not in the manual?

Questions and answers

Summary of Contents for CopperOptics PairGain PG-FLEX PLUS PRL-770 List 2E

  • Page 1 PG-F Indoor Remote Terminal P l u - F l Enclosure I N A PRL-770 List 2E PRL-779 List 1E Part Number: 150-1670-52 150-1679-51 CLEI Code: S9MSBA0A S9MSEH0A ECHNOLOGIES NGINEERING ERVICES ECHNICAL RACTICE ™950-779-115-020¨ 950-779-115-02 ECTION...
  • Page 2 950-779-115-02, Revision 02 Revision History of This Manual Revision Release Date Revisions Made December 13, 1999 Initial release. March 17, 2000 Add 4 POTS support information and change reference label graphics. ©Copyright 2000 PairGain Technologies, Inc. Plus PairGain and PG-Flex are registered trademarks, and PG-Flex , The Power Behind DSL Access and the PairGain logo design are trademarks of PairGain Technologies, Inc.
  • Page 3 950-779-115-02, Revision 02 Using This Technical Practice SING ECHNICAL RACTICE Three types of icons appear in the text. Notes indicate information about special circumstances. Cautions indicate the possibility of equipment damage or the possibility of personal injury. The ESD Susceptibility symbol indicates that a device or assembly is susceptible to damage from electrostatic discharge.
  • Page 4 Inspecting Your Shipment 950-779-115-02, Revision 02 March 17, 2000 PRL-770 and PRL-779 List 1E and 2E...
  • Page 5: Table Of Contents

    950-779-115-02, Revision 02 Table of Contents ABLE OF ONTENTS Overview ____________________________________________________________________________ 1 Integrated Channel Testing ........................1 Metallic Fallback..........................2 Specifications .............................2 Installation and Turn-up _______________________________________________________________ 4 Required Tools and Test Equipment....................4 Preparing the RT ..........................5 Mounting the RT..........................5 Wall Mounting........................5 Line-up Mounting........................7 Wiring the RT ............................9 Turn up and Testing .........................12 Fault Isolation _______________________________________________________________________ 12...
  • Page 6 Table of Contents 950-779-115-02, Revision 02 March 17, 2000 PRL-770 and PRL-779 List 1E and 2E...
  • Page 7: Overview

    950-779-115-02, Revision 02 Overview VERVIEW ® Plus The PairGain PG-Flex ™ PRL-770 List 2 E and PRL-779 List 1 E, provides interfaces for LS/GS POTS subscribers. The PRL-779 supports Loop Start and Ground Start (LS/GS) POTS, allows Tip and Ring polarity reversal for support of Millennium pay phones, and implements TR-08 channel testing.
  • Page 8: Metallic Fallback

    Overview 950-779-115-02, Revision 02 ETALLIC ALLBACK Metallic fallback provides a direct connection from the CO to subscriber number one under fault conditions. The metallic fallback feature is a provisionable item. You can disable this feature through the user screens. Service is provided to the subscriber assigned to the LS/GS line in the affected COLU. At the RT, the system exits metallic fallback and attempts to synchronize if either LS/GS number one or the HDSL Tip to Ring pair is shorted for at least 3 seconds, and then released for at least 3 seconds.
  • Page 9 950-779-115-02, Revision 02 Overview LS/GS Interface Analog Impedance RT supervisory range p lus 430 f or handset; or 3.5 kft on 26 AWG; 5.7 kft on 24 AWG;    9.2 kft on 22 AWG Detection of Loop Open >10 k Idle State Voltage -48 V minimum...
  • Page 10: Installation And Turn-Up

    Installation and Turn-up 950-779-115-02, Revision 02 NSTALLATION AND The PRL-770 List 2 E and PRL-779 List 1 E are a listed accessory to be used only with PairGain Model PLL-729 or PLL-735 List 1 or equivalent. Installation and maintenance to be performed by qualified service personnel only. This RT is to be installed in a restricted access location.
  • Page 11: Preparing The Rt

    950-779-115-02, Revision 02 Installation and Turn-up REPARING THE HDSL and subscriber wiring are threaded through the Insulation Displacement Contact (IDC) connector located on the right-hand side of the RT. Use either the wall mounting or the line-up template provided in the Mounting Kit for the RT wall positioning.
  • Page 12 Installation and Turn-up 950-779-115-02, Revision 02 Use the two No. 6 x 1-inch wood screws provided in the Mounting Kit to attach the RT to the wall of the restricted access area (see Figure P l u - F l Figure 3.
  • Page 13: Line-Up Mounting

    950-779-115-02, Revision 02 Installation and Turn-up Line-up Mounting Use the back panel of the enclosure, or the enclosed hole pattern drawing as a template for marking the locations of mounting holes as shown in Figure Figure 4. Line-up Mounting Dimensions PRL-770 and PRL-779 List 1E and 2E March 17, 2000...
  • Page 14 Installation and Turn-up 950-779-115-02, Revision 02 Use the two No. 6 x 1-inch wood screws provided in the Mounting Kit to attach the RT to the side of the restricted access area (see Figure P l u - F l Figure 5.
  • Page 15: Wiring The Rt

    950-779-115-02, Revision 02 Installation and Turn-up IRING THE Wiring the RT consists of three major steps: • attaching the frame ground wire • attaching the HDSL Tip and Ring wires • attaching the subscriber line wires Before setting up the equipment, select a location that will allow sufficient access to wiring connections from the telco access door.
  • Page 16 Installation and Turn-up 950-779-115-02, Revision 02 Attaching the Frame Ground, HDSL and Subscriber Line Wires To install the RT wires, do the following: This RT does not provide primary protectors on the HDSL or subscriber pairs. The primary protection for HDSL pairs must be an integral part of the premises wiring. If the subscriber wiring is routed outside of the premises for any reason, then primary protection for subscriber pairs must also be an integral part of the premise wiring.
  • Page 17 950-779-115-02, Revision 02 Installation and Turn-up For the FGND and Subscriber Line wires, pivot the IDC connector upward, then insert the wire pair through the tip and ring holes (see Figure 8). Each wire entry hole accepts one unstripped solid copper wire 22-24 American Wire Gauge (AWG) with a maximum insulation diameter of 1.52 mm.
  • Page 18: Turn Up And Testing

    Fault Isolation 950-779-115-02, Revision 02 URN UP AND ESTING To continue the installation of your PRL-770 and PRL-779 for readiness: Plus Ensure that at least one COLU is installed into the PG-Flex COT shelf. Refer to the appropriate COLU Technical Practice for verifying the COLU installation. Locate the HDSL Tip and Ring on the protector block or punchdown, apply a short between the HDSL Tip and Ring conductors for at least 3 seconds.
  • Page 19: Subscriber Reported Faults

    950-779-115-02, Revision 02 Fault Isolation Table 1. COLU LED Fault Isolating (Cont.) Mode Condition Procedure argin Flashing • distance limitation exceeded 1 Initial installation, check engineering records for distance between COT shelf and RT. • fault in HDSL line 2 If existing installation, measure loss of HDSL line to ensure that the maximum attenuation value has not been exceeded.
  • Page 20 Fault Isolation 950-779-115-02, Revision 02 Table 2. Subscriber Fault Isolating (Cont.) Conditions Causes Procedures Phone does • faulty subscriber station 1 If phone stops ringing when using a butt set at the subscriber location, the subscriber's station internal resistance is too high. Replace phone. not stop instrument ringing...
  • Page 21: Abbreviations

    950-779-115-02, Revision 02 Abbreviations BBREVIATIONS American Wire Gauge Central Office COLU Central Office Line Unit Central Office Terminal Electrostatic Discharge HDSL High-bit-rate Digital Subscriber Line Insulation Displacement Contact Light-emitting Diode LS/GS Loop Start and Ground Start Mechanized Loop Test PG-Plus Alarm Unit PG-Plus Management Unit POTS Plain Old Telephone Service...
  • Page 22: Product Support

    Product Support 950-779-115-02, Revision 02 RODUCT UPPORT ECHNICAL UPPORT PairGain Technical Assistance is available 24 hours a day, 7 days a week by contacting PairGain Customer Service Engineering group at: 800.638.0031 or 714.730-3222 Telephone: 714.832.9924 Fax: support@pairgain.com Email: During normal business hours (7:30 AM to 5:30 PM, Pacific Time, Monday - Friday, excluding holidays), technical assistance calls are normally answered directly by a Customer Service Engineer.
  • Page 23: Advance Replacement

    950-779-115-02, Revision 02 Product Support PAIRGAIN DISCLAIMS ALL OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO ITS PRODUCTS AND ANY ACCOMPANYING WRITTEN MATERIALS. FURTHER, PAIRGAIN DOES NOT WARRANT THAT SOFTWARE WILL BE FREE FROM BUGS OR THAT ITS USE WILL BE UNINTERRUPTED OR REGARDING THE USE, OR THE RESULTS OF THE USE, OF THE SOFTWARE IN TERMS OF CORRECTNESS, ACCURACY, RELIABILITY OR OTHERWISE.
  • Page 24: Fcc Compliance

    Product Support 950-779-115-02, Revision 02 Include the following information, in writing, along with the equipment you are returning: • Company name and address. • Contact name and telephone number. • The shipping address to which PairGain should return the repaired equipment. •...
  • Page 25 950-779-115-02, Revision 02 Product Support FCC C OMPLIANCE This unit complies with the limits for Class B digital devices pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 26 Corporate Office 14402 Franklin Avenue Tustin, CA 92780 Tel: 714.832.9922 Fax: 714.832.9924 For Technical Assistance: 800.638.0031 714.730.3222...