HAINKE FIW 202 Operation Manual

Electronic solenoid valve control

Advertisement

Quick Links

Operation manual
Electronic solenoid valve control
FIW 202
Version V1.0 · 04/2022

Advertisement

Table of Contents
loading

Summary of Contents for HAINKE FIW 202

  • Page 1 Operation manual Electronic solenoid valve control FIW 202 Version V1.0 · 04/2022...
  • Page 2 ​ Hainke Filteranlagen GmbH An der Imbäke 7 27798 Hude Germany Tel: +49 4408 8077-0 Fax: +49 4408 8077-100 Email: info@hainke.de Internet: www.hainke.de Electronic solenoid valve control · V1.0 · 04/2022 Operation manual...
  • Page 3: Table Of Contents

    Notes on particular conditions for safe use in hazardous area Zone 22  ... 2 Intended use ......................3 Technical data  ...................... 4 Assembly and installation ..................Electrical connection  ..................Dimension plan FIW 202  ................Connection plan FIW 202  ................5 Start-up  ......................... Operation manual Electronic solenoid valve control · V1.0 · 04/2022...
  • Page 4: Safety

    • EN 55014-1:2012 • EN 60204-1:2012 • EN 60079-0:2014 • EN 60079-31:2014 The named standards and directives can be examined at HAINKE Filteranlagen GmbH . Marking electrical equipment for potentially explosive atmospheres Marking according to Dir- ective 2014/34/EU: II 3D...
  • Page 5: Operation Of The Control In The Mounting Enclosure

    2 | Intended use Areas of use Category 3 Zone 22 non-conductive dust Equipment group II Cat- Equipment designed to be capable of functioning in conformity egory 3D with the operating parameters established by the manufacturer and ensuring a normal level of protection. Electrical equipment for use Equipment in this category is intended for use in areas in which ex- in areas with combustible...
  • Page 6: Technical Data

    1.6 A medium lag Quiescent current in- typically 40 mA typically 80 mA typically 60 mA Type FIW 202 E in the polycarbonate mounting en- closure Output data 2 solenoid valve outputs 24 VDC, output power max. 24 W / 1 A Pulse time approx. 50 −  500 ms settable Pause time approx.
  • Page 7: Assembly And Installation

    Target group Unless assigned otherwise, the assembly and installation are carried out by skilled per- sonnel of HAINKE Filteranlagen GmbH . Work on the electrical installation is only carried out by electrically skilled personnel. Work on live parts is not planned.
  • Page 8: Electrical Connection

    4 | Assembly and installation Electrical connection NOTICE Property damage due to wrong supply voltage The connection of 115 VAC or 230 VAC to a control for 24 VDC supply voltage leads to ir- reparable damage to the whole control. –...
  • Page 9: Dimension Plan Fiw 202

    4 | Assembly and installation Dimension plan FIW 202 Operation manual Electronic solenoid valve control · V1.0 · 04/2022...
  • Page 10: Connection Plan Fiw 202

    4 | Assembly and installation Connection plan FIW 202 Electronic solenoid valve control · V1.0 · 04/2022 Operation manual...
  • Page 11: Start-Up

    5 | Start-up Start-up WARNING Risk of injury due to the escape of a potentially explosive atmosphere consisting of dust/air mixtures ü Operation with the cover open is prohibited. 1. Before opening the cover, ensure that no potentially explosive atmosphere exists. 2.
  • Page 12 Keeping the World Flowing for Future Generations...