(including but not limited to improper maintenance and storage), accidents, improper installation, modifications (included but not limited to the use of non-original parts or accessories not authorized by Renova), improper adjustment or repair. All parts subject to normal wear are excluded from the guarantee.
The manufacturer’s instructions must be read and completely understood before the installation and use of the product and, in the case of breakdown, before any check intervention or recourse at the Renova’s technical assistance. The operator must understand the manufacturer’s instructions and be aware of the dangers. ...
ASSEMBLY The assembly is made through rapid and simple operations. 1. Initial situation after the removal from the box (fig.1) 2. Insert the supply pipe into the pipe fitting of the motor (fig.2) 3. Place the fastener in its fixing position paying attention to the correct alignment of the handle in relation to the mechanical lock for the rotation (fig.3) 4.
fig. 3 fig. 4 fig. 5 USE WITHOUT COUNTER SPRINGS Counter springs are mounted on the device. They allow the rollers to get into contact between them. The springs are designed and calibrated to guarantee the contact between the 3 rollers only when compressed by the roll weight.
INSTALLATION Below please find some simple steps and devices to better use this quality product. The pneumatic motor air supply is essential for the correct functioning of the moviroll. You need to follow small but essential measures in order to achieve maximum performance without loss of power or machine malfunctions The pneumatic motor on moviroll needs treated compressed, filtered and lubricated air at bar.
Page 9
Connect a pipe with an internal diameter of at least 12 mm and a length depending on the distances need cover. Spiral pipe 15 mt. 12X15 mm pressure rating up to 10 bar. Connect the end of the tube to a pipe-fitting as shown in the picture.
OPERATING PRESSURE moviroll correctly works in a pressure range that goes from 6 to 7 bar. It is important to verify that the input pressure does not drop under 6 bar when running motor. In the case the pressure drops under this value, increase the pressure that supplies the moviroll to obtain a work pressure of about 6 bar continuously.
The non-compliance with the above parameters may cause damage to the internal components of the motor. In this case Renova srl disassociates itself from any responsibility. Any foreign matter that gets into the motor such as dirt, metallic powder or other, may cause a permanent damage and the subsequent seizure of it. The greatest attention must be paid to the methods of air filtering.
CONNECTION SCHEME PREASSURE AIR LINE Clean the filter Fill with oil INSTRUCTIONS FOR A PROPER USE moviroll versions MR100S and MR200S with curved handle must be used with the handle in their appropriate locations (see the drawing). Any other position or use of the handle doesn’t guarantee the integrity of the handle itself.
(improper use of the moviroll as brake). Renova’s moviroll is provided with its original air supply kit (code MVRK001) in order to ensure the maximum performance and durability of moviroll. If supplying moviroll with untreated air, a power reduction of up to 70% is possible and the premature wear of its internal parts may occur.