1. Description

The Digalox
®
DPM72 devices via XBEE radio technology (2.4 GHz mesh network). In this way,
measured values from remote devices can be integrated into a display as remote
values. Using the radio interface the devices can also be configured individually.
The mesh network offers a robust connection that ensures continued operation even
if a single radio node fails. Each additional node acts as a router, increasing the
range of the network.

2. Specification

• 2.4 GHz (IEEE 802.15.4) mesh network
• Radio module: XB3-24Z8UM-J
(Digi XBee 3 Zigbee 3.0, 2.4GHz, Micro, U.FL Ant, MMT)
• Antenna connector: SMA
• Range between two radio nodes: up to 60 m indoors, up to 1200 m outdoors
with a clear line of sight

3. Connections

Digalox
Instruction manual (Rev-2022-08)
DPM72 devices with XBEE interface can communicate with other
®
DPM72 XBEE interface
----- 1 / 4 -----

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Digalox DPM72 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TDE Instruments Digalox DPM72

  • Page 1 Digalox ® DPM72 XBEE interface Instruction manual (Rev-2022-08) 1. Description The Digalox ® DPM72 devices with XBEE interface can communicate with other DPM72 devices via XBEE radio technology (2.4 GHz mesh network). In this way, measured values from remote devices can be integrated into a display as remote values.
  • Page 2 4. Configuration To configure a device, plug the XBEE stick into the computer. The driver of the stick is installed automatically if the computer is connected to the Internet. If the XBEE connection settings of the device should be reset, short-circuit connector J8 and open it again.
  • Page 3 6. Status LEDs There are three LEDs on the back of the device that indicate the device status. Description Status Power (green) shines Device on Assoc (orange) shines Device not connected Assoc (orange) flashes Device connected Act (rot) shines Device sends data 7.
  • Page 4 11 = Device busy 12 = Gateway path unavailable 13 = Gateway target device failed to respond 9. Contact details TDE Instruments GmbH, Gewerbestraße 8, D-71144 Steinenbronn Phone: +49 7157 20801 E-mail: info@tde-instruments.de Internet: www.tde-instruments.de, www.digalox.com ----- 4 / 4 -----...