BKT Elektronik BPS2000v2 Operating Instructions Manual

BKT Elektronik BPS2000v2 Operating Instructions Manual

Monitoring power distribution

Advertisement

O O pera ng Instruc ons
BPS2000v2 Monitoring Power Distribu on
Ver.01.22
Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit
a ng Instruc ons - BPS2000v2 Moni
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BPS2000v2 and is the answer not in the manual?

Questions and answers

Summary of Contents for BKT Elektronik BPS2000v2

  • Page 1 O O pera ng Instruc ons BPS2000v2 Monitoring Power Distribu on Ver.01.22 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit a ng Instruc ons - BPS2000v2 Moni...
  • Page 2: Table Of Contents

    .......35 13. Technical parameters of BPS2000 unit ………………………………………………….………………………………..……….40 13.1 Control module specifica on …..…….…………………..……………………………………………………...…………41 13.2 Addi onal accessories ……….…………….…………………………………...…………………………………...…………41 14. Warranty .……………………………….………………………………………………………………….………………………….………..42 15. BPS2000 unit so ware update……………………..…………………………………………………….……….…….…..…..46 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 3: Safety Precau Ons

    The BPS2000 units are used in IT, ICT, Data Center and power distribu on environments. In addi on, they allow monitoring of electrical parameters at the power input of the PDU along with monitoring of environ- mental condi ons in the server rack. Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 4: Installa On Of Bps2000 Unit

    PDU brackets for BKT SRS/SSRS racks (ordered separately) Index: 111SA200018.3 Example of moun ng the unit in 4DC rack cabinet, moun ng to the 19" profile front and side view Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 5: Unit Bps2000 General Characteris Cs

    The web interface is available from any web browser in Polish and English. Communica on is carried out using built-in network and communica on protocols: • SNMPv1/v2c/v3, Modbus RTU, Modbus TCP/IP • HTTP, SMTP, Telnet • IPv4/IPv6 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 6: View Of The Control Module, Including A Descrip On Of The Connectors

    8. SB - Sensor Box environmental condi ons module connec on port 9. OUT - serial communica on output port RS485 (Modbus RTU/SNMP) 10. IN - serial communica on input port RS485 (Modbus RTU/SNMP) 11. LCD screen Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 7: Lcd Display Interface For 250V Single Phase Version

    Press UP Press 0.00A 0.00A 168 000 237.6V 0.0kW 237.6V 0.0kW 000012.5kWh PF-0.00 Screen 1 Screen 2 Screen 3 Screen 4 Press 250 V 44 °C 99 % Screen 5 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 8: Lcd Display Interface For 400V Three Phase Version

    Read/write*: Se ng of threshold values, maximum Phase(L2) / Load(16A) / Voltage(276.0V) / Temperature(40°C) / Humidity(99%) Screen 11 Read/write*: Se ng of threshold values, maximum Phase(L3) / Load(16A) / Voltage(276.0V) / Temperature(40°C) / Humidity(99%) Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 9 235.0V 0.0kW 234.9V 0.0kW PF-0.00 PF-0.00 000019.1kWh Screen 4 Screen 5 Screen 6 Screen 7 Press Press Press Press 40°C 40°C 40°C Screen 8 Screen 9 Screen 10 Screen 11 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 10: Managing The Bps2000 Unit

    T T he default username is admin with the password admin. 3. A er logging in, the web interface is available in two language versions (Polish and English). Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 11 3. Configura on of alarm thresholds for the module SensorBox environmental condi ons temperature and humidity from port 1 of the SensorBox module temperature and humidity from port 2 of the SensorBox module Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 12 Community write: set to public by default Account (required for SNMPv3 only) Password (required only for SNMPv3) Private key (required for SNMPv3 only) IP address of trap 1 IP address of trap 2 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 13 BPS2000v2 web interface Telnet 1. Telnet se ngs Telnet: choose Enable or Disable Telnet account: enter account name Telnet password: enter account password Telnet Port: default is Port 23 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 14 Date (YYYY-MM-DD): enter year, month and day Time (hh:mm:ss): enter hour, minute, second „Get local date/ me” Allows to download the current date and me from your local device (computer). Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 15 Contains informa on about ac ons performed by the user such as: logging in, changing alarm thresholds, etc. The event log buffer will be cleared when 500 entries are exceeded. Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 16 Disable: Update locked An addi onal TFTP applica on is required to perform the update. Details of how to perform the update are available in the so- ware update chapter. Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 17: Se Ng The Unit Bps2000 To The Factory Configura On

    Remove the control modu- Hold down the Menu the unit housing rand elease the Menu le from the PDU housing bu on for 6 seconds bu on a er 6 seconds Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 18: Access Via Telnet Protocol

    When all steps are successfully completed, access to the Telnet console window will be enabled. A er connec ng to the PDU, enter the username (default: admin) and the password (default: admin). Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 19 To select one of the commands, enter master or slave (depending on the unit opera on mode) and a com- mand, e.g. To display the current load, execute the mas- ter load command Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 20 Users - allows you to change the user and password for access. BPS2000v2 cmd interface 4. Network Se ngs Network Se ngs Adress IPv4, Subnet masks IPv4, Gates, DNS. Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 21 7. SMTP Se ngs Read/se ngs for: account, password, SMTP server and port, number of no fica ons, cyclic no fica ons (from 1 to 10 sec), recipient e-mail. Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 22 • temperature and humidity • PDU supply voltage for each phase BPS2000v2 cmd interface 9. Clear energy Phase Clear energy Phase - reading/rese ng current load for each phase. Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 23 Restart - restar ng the unit Restart to factory default - restar ng the unit and restoring factory defaults. cmd interface 11. Logout Logout - logging out of the command line (Telnet). Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 24: Access Via Snmp Protocol

    We connect subsequent units in an iden cal manner. Connect the NET port of the MASTER unit to the network port of the computer/network switch. LAN network Slave5 Master Slave1 Slave2 ….. Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 25: Oid Table

    Master Line 3, frequency L3 .1.3.6.1.4.1.47394.1.2.24.0 masterAc veEnergyL3 Master Line 3, ac ve energy L3 .1.3.6.1.4.1.47394.1.2.25.0 masterApparentEnergyL3 Master Line 3, apparent energy L3 .1.3.6.1.4.1.47394.1.2.26.0 masterPFL3 Master Line 3, power factory L3 .1.3.6.1.4.1.47394.1.2.27.0 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 26 Slave 1, votage L3 slaveOneVoltageL3 .1.3.6.1.4.1.47394.1.3.20.0 Slave 1, ac ve power L3 slaveOneAc vePowerL3 .1.3.6.1.4.1.47394.1.3.21.0 slaveOneReac vePowerL3 .1.3.6.1.4.1.47394.1.3.22.0 Slave 1, reac ve power L3 slaveOneApparentPowerL3 .1.3.6.1.4.1.47394.1.3.23.0 Slave 1, apparent power L3 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 27 .1.3.6.1.4.1.47394.1.4.18.0 Slave 2, power factor L2 slaveTwoCurrentL3 .1.3.6.1.4.1.47394.1.4.19.0 Slave 2, total current L3 slaveTwoVoltageL3 .1.3.6.1.4.1.47394.1.4.20.0 Slave 2, total votage L3 slaveTwoAc vePowerL3 .1.3.6.1.4.1.47394.1.4.21.0 Slave 2, ac ve power L3 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 28 .1.3.6.1.4.1.47394.1.5.16.0 Slave 3, ac ve energy L2 slaveThreeApparentEnergyL2 .1.3.6.1.4.1.47394.1.5.17.0 Slave 3, apparent energy L2 slaveThreePFL2 .1.3.6.1.4.1.47394.1.5.18.0 Slave 3, power factor L2 Slave 3, total current L3 slaveThreeCurrentL3 .1.3.6.1.4.1.47394.1.5.19.0 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 29 Slave 4, ac ve power L3 slaveFourAc vePowerL3 .1.3.6.1.4.1.47394.1.6.21.0 Slave 4, reac ve power L3 slaveFourReac vePowerL3 .1.3.6.1.4.1.47394.1.6.22.0 slaveFourApparentPowerL3 .1.3.6.1.4.1.47394.1.6.23.0 Slave 4, apparent power L3 slaveFourFrequencyL3 .1.3.6.1.4.1.47394.1.6.24.0 Slave 4, frequency L3 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 30 Slave 5, apparent energy L2 slaveFivePFL2 .1.3.6.1.4.1.47394.1.7.18.0 Slave 5, power factor L2 slaveFiveCurrentL3 .1.3.6.1.4.1.47394.1.7.19.0 Slave 5, total current L3 slaveFiveVoltageL3 .1.3.6.1.4.1.47394.1.7.20.0 Slave 5, total votage L3 Slave 5, power L3 slaveFiveAc vePowerL3 .1.3.6.1.4.1.47394.1.7.21.0 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 31 Slave 5, humidity1 slaveFiveHumidity1 .1.3.6.1.4.1.47394.1.7.32.0 Slave 5, humidity2 slaveFiveHumidity2 .1.3.6.1.4.1.47394.1.7.33.0 slaveFiveSmoke .1.3.6.1.4.1.47394.1.7.34.0 Slave 5, smoke slaveFiveWater .1.3.6.1.4.1.47394.1.7.35.0 Slave 5, water slaveFiveDoor1 .1.3.6.1.4.1.47394.1.7.36.0 Slave 5, door1 slaveFiveDoor2 .1.3.6.1.4.1.47394.1.7.37.0 Slave 5, door2 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 32: Access Via Modbus Tcp Protocol

    This port can be changed to any port in the management interface of the power unit available in the Ne- twork tab of Modbus TCP/IP. Diagram of connec on of power units using Modbus TCP protocol. Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 33: Access Via Modbus Rtu Protocol

    Blue RS485 -A Rx+ White and blue RS485 -B Rx- Diagram of the connec on of the BPS2000 strip to the ModBusRTU Slave32 Slave3 Slave1 Slave2 ….. ModBus gateway Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 34 Slave address: (Slave1-Slave32) Baud rate : 4800 bps, 9600 bps, 19200 bps, 38400 bps Parity: : NONE, ADD, EVEN Data bits (8 lub 9) Stop bits (1 lub 2) Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 35: Modbus Rtu/Tcp Memory Map

    Apparent power L3 00014 0x000E =register/10 2 Bytes Frequency L1 00015 0x000F =register/100 2 Bytes Frequency L2 00016 0x0010 =register/100 2 Bytes Frequency L3 00017 0x0011 =register/100 2 Bytes Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 36 =register/10 2 Bytes Humidity 00056 0x0039 =register/10 2 Bytes Humidity 00057 0x003A =register/10 2 Bytes Door 1 1=Open 0x003B 2 Bytes 2=Closed Door 2 1=Open 0x003C 2 Bytes 2=Closed Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 37 2 Bytes High Alarm Temperature1 00078 0x004C ᵒ =register 2 Bytes Low Alarm Temperature2 00079 0x004F ᵒ =register 2 Bytes High Alarm Temperature2 00080 0x0050 ᵒ =register 2 Bytes Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 38 16= High Alarm Temperature 2 alarm 00095 0x005F 2 Bytes Humidity alarm 00096 0x0060 2 Bytes Humidity 1 alarm 00097 0x0061 2 Bytes Humidity 2 alarm 00098 0x0062 2 Bytes Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 39 R24 - register value 24 Example Phase 1 ac ve energy meter readings: 1800.12 kWh Reading the values of registers R21-R24 of the ac ve energy meter Phase 1 R21=0 R22=27 R23=119 R24=184 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 40: Technical Parameters Of Bps2000 Unit

    Moun ng Ver cal moun ng or horizontal depending on models 1U 19” or 0U Temperature 0°C ÷ 60°C Environment Rela ve humidity 10% ÷ 95% Storage -20°C ÷ 70°C Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 41: Control Module Specifica On

    DIN49440/IEC 320 C14 — 11480798.03 DIN49440/IEC 320 C19 — 11480799.03 Flood sensor* (1134CWS01) *Required connec on of SensorBox environmental monitoring module to SB port of BPS2000 strip control module Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 42: Warranty

    The following provisions rela- ng to the device also apply to the components thereof. BKT ELEKTRONIK may decide to replace the de- fec ve device with a defect-free one instead of repairing it. Replacement will also be carried out under the following condi ons.
  • Page 43 The completed complaint form with a copy of the invoice must be sent to the address: reklamacja@bkte.pl The claimed device should be delivered to: BKT ELEKTRONIK Sp. z o.o., Ul.Lochowska 69, 86-006 Biale Blota Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 44 Buyer/Repor ng Person. 14.5.3 If the device is to be delivered to BKT ELEKTRONIK, it shall be delivered in original or subs tute packaging ensuring safe transport and storage condi ons similar to those provided by the origi- nal packaging.In the absence of factory packaging, the risk of damage to the device during trans-...
  • Page 45 The Buyer loses the rights under this warranty in case of: 12.6.1 any repair or modifica on of the device on its own or by a third party, or entrus ng the perfor- mance of the repair to a person other than an authorized BKT ELEKTRONIK service technician;...
  • Page 46: Bps2000 Unit So Ware Update

    15.2 Log in to the BPS2000/BPS2500 PDU by entering the unit's current IP address in a web browser, or via the default IP address: 192.168.0.163 Default login creden als User name: admin Password: admin Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 47 Field: Enter the current IP address of the BPS2000/BPS2500 strip or the default IP address: 192.168.0.163 Port Field: 69 Local File: Enter the path of the update file: e.g.: BPS2500-3.bin key : Will start uploading the update file to the unit BPS2000/BPS2500 Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...
  • Page 48 2. a stable network connec on (Ethernet) between the computer and the unit BPS2000/BPS2500. Failure to maintain any of the above points will result in erroneous so ware upload and loss of communica on and management over the unit. Opera ng Instruc ons - BPS2000v2 Monitoring Power Distribu on Unit...