6. OPERATION
Temperature
Plus/minus
fig.1
6.1.
SET UP
6.1.1.
Select your cleaning solution and fill 2/3rds of the tank. DO NOT exceed the filling line. Be aware of the displacement volume of the
objects being treated to avoid overspill.
DANGER! DO NOT use alcohol, gasoline or flammable solutions. Doing so could cause a fire or explosion. Use only water-based
solvents.
6.1.2.
Place the items into the basket, Slowly lower the basket into tank. DO NOT allow items to contact the tank bottom and always use the
basket to immerse items. The solution should cover the items - see section 6.1.1.
6.1.3.
A: Plug the cleaner into (earthed) mains supply.
B: Turn mains supply on and turn on the power switch on rear side of the machine.
NOTE:
After turning power on, the value you see on the temperature display is the actual temperature. To see set temperature of the
solution, press the temperature button. The current time settings in minutes and seconds is shown the double width window.
6.2.
TIMER
6.2.1.
Press
or
Time is shown in minutes and seconds (fig.1). Maximum timer setting is 30 minutes.
NOTE:
6.3.
HEATING
6.3.1.
to start/stop heating. Press
Press
6.3.2.
To get the best cleaning result, the solution's temperature should be 40° to 60°C. Warm water and dish washing liquid can soften
grease and improve cleaning results. Heating range is from 5
6.3.3.
When setting the temperature, if you want the temperature of the bath to be higher than the current temperature, press
'Heat' button. The heating will come on. If the required temperature is below the ambient temperature, the heating will not come on.
Heating does shut off automatically, if timer is used, when the timer reaches zero.
6.4.
DEGAS MODE
6.4.1.
To degas a fresh solution, use the degas mode. Press the degas button 3 times within 3 seconds.
6.4.2.
The unit will cycle through 6 second and 3 second periods until the time reaches zero.
6.5.
NORMAL MODE
6.5.1.
After timer and temperature setting, press
'normal mode': continuously working with full ultrasonic power and countdown display.
6.6.
SOFT MODE
6.6.1.
Set the timer and temperature, press
to another mode, press
turn on; To stop working, press
off.
© Jack Sealey Limited
Temperature
Current/Set
Heat
On / Off
Degas
to set the cleaning time. The timer will count down to 00:00, the tank will switch off.
or
'Normal' button, the Ultrasonic LED (fig.1) will turn on and the device will work in
, 'soft mode', the button light will turn on and the device will work in soft mode. To transfer
'Degas' or
'normal', the 'soft mode' light will turn off and indicator light of 'degas' or 'normal' will
'soft' again, then both heating and ultrasonic will stop and the corresponding button light will turn
Original Language Version
Set Time
Set Time
Minutes
Seconds
Normal
On / Off
Soft Mode
to set the temperature (displayed in °C)
C to 80
o
o
C.
SCT27.V2, SCT09.V2, SCT03.V2 Issue 2 (2) 07/04/22
Time
Plus / minus