NK TECHNOLOGIES APS Series Instructions

Ac power transducer

Advertisement

Quick Links

Specifi cations
Output
4-20mA
Output Limit
22mA
Accuracy
1% FS
Response Time
100 mS (to 90% of step change)
Frequency Range
10-400 Hz
Power Supply
24VDC Nominal Loop Powered 36 VDC
Maximum
Power Inputs Expressed as:
Amps
2-120A
kW
0.5 kW to 100 kW
HP
1/4HP@120 VAC to 150 HP@480 VAC
Voltage Input
120, 240 or 480 VAC Nominal
Voltage Variation
+/- 25% of nominal
Amperage Over-range
150% FS indefi nitely
300% FS 10 Seconds
600% FS 5 Seconds
Output Terminals
Finger-safe captive screw, 14-22 AWG
Torque to 9.0 inch pounds
Voltage Input
Up to 14AWG wire, 600V max.
Fusing
External fusing of voltage input
recommended
Indication
Power LED
Input Conditions
Across the line motors and VFDs
Environmental
-4 to 140 Deg F, -20 to 60 Deg C
Power Supply
V
= 12VDC + (R
x .020A)
L
L
Where: V
= Minimum Loop Power
L
32 V
R
= Total Loop Resistance
L
(Ohms)
LOOP
22 V
POWER
(VDC)
12 V
0
250
500
Total Loop Impedance (Ohms)
Model Number Key
Example: APS4-420-24L-9.0
Single Phase watt transducer, 480VAC Input, 4-20mA output
with 24VDC Loop powered, 9.0kW max input. Input may be
wired with two opposite current wire passes.
APS
Voltage
1
120 VAC
2
240 VAC
4
480 VAC
Note:
for each voltage input.
Know Your Power
Other NK Technologies Products Include:
AC & DC Current Switches
Ground Fault Sensors
Voltage & Power Transducers
Current Transformers (CTs)
Operating
Range
750
1000
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
4 2 0
2 4 L
Output
Power Supply
420 4-20 mA
24L 24VDC Loop-
Powered
Full scale kW
0.5
0.75
1
5
10
20
Not all kW ranges are available
50
75
100
INSTRUCTIONS
APS Series
AC Power Transducer
True Power of 1φ or 3φ Balanced Loads
Quick "How To" Guide
1. Route wire to be monitored through aperture. For
480VAC and/or 3 phase installations, ensure wires
are routed through the aperture in a two-pass con-
fi guration as shown on reverse side.
2. Mount the sensor to a surface if needed.
3. Connect voltage and output wiring to appropriate
terminals. Ensure voltage is derived from same
line that runs through the aperture. Use fi eld sup-
plied fuse or circuit breaker per standard wiring
practice.
A. Use up to 14 AWG copper wires, tighten ter-
minals to 9.0 inch-pounds torque.
B. Make sure loop power meets specifi cations.
APS Inst. Rev 4, 10/11 P/N 790180010

Advertisement

loading

Summary of Contents for NK TECHNOLOGIES APS Series

  • Page 1 fi guration as shown on reverse side. Input Conditions Across the line motors and VFDs Other NK Technologies Products Include: Environmental -4 to 140 Deg F, -20 to 60 Deg C 2. Mount the sensor to a surface if needed.
  • Page 2 Wiring Details and Output Calibration (con’t) Description APS Series are single phase power transducers. They provide an analog signal proportional to the true power consumed by the monitored load. They can be applied on single phase loads and on balanced three phase loads.

This manual is also suitable for:

Aps4-420-24l-9.0