SCG-5608 User Manual Ver. 1.0 Overview 1.1 Introduction SCG-5608 is an industrial Console server with 8 RS232 ports. Users can remotely access 8 serial devices via this product. 1.2 Features ⚫ 8 RS232 ports ⚫ Support TLS v1.2 ⚫ Support frame delimiter function ⚫...
Page 5
SCG-5608 User Manual Ver. 1.0 ⚫ 8:8 on a local area network Figure 1-2 8:8 on a local area network ⚫ Serial tunnelling on a local area network Figure 1-3 Serial tunnelling on a local area network ⚫ 1:8 on the Internet Figure 1-4 1:8 on the Internet https://www.eztcp.com...
SCG-5608 User Manual Ver. 1.0 1.5 Interfaces Figure 1-5 Interfaces 1.5.1 Power The product's power is supplied through the PWR1 port or PWR2 port, and it is not a problem to connect both ports at the same time. ⚫ PWR1 port The input voltage is DC 8.5V to 38V.
SCG-5608 User Manual Ver. 1.0 1.5.2 Function Button This button is used to implement a factory reset. 1.5.3 SETUP Port This port is for administrative use only. 1.5.4 Ethernet SIG-5608 provides 10/100Mbps Ethernet. The pin assignment is as follows: Figure 1-7 Ethernet ⚫...
SCG-5608 User Manual Ver. 1.0 1.5.5 RS232 Port This port is a 1 X 8 RJ45 connector. Figure 1-8 RS232 Port ⚫ RS232 pin assignment Name Description Wiring Request To Send Optional Data Terminal Ready Optional Transmit Data Required Ground...
SCG-5608 User Manual Ver. 1.0 1.5.6 LED LED operations by device status are as follows: When the supplied power is stable: PWR When the supplied power is NOT stable: PWR When an IP address is NOT assigned: LINK & ACT When a network is connected with and IP address assignment: LINK &...
SCG-5608 User Manual Ver. 1.0 Preparation 2.1 Installing the Setting Tool You need a program which is called spFinder to use this product. Download the program on our web site and install it on your PC. Functions of the spFinder are as follows: ⚫...
SCG-5608 User Manual Ver. 1.0 Settings 3.1 Network 3.1.1 Obtain an IP address automatically This product can automatically obtain an IP address by DHCP. A DHCP server is required to use this. Figure 3-1 Obtain an IP address automatically ⚫ Select the [Obtain an IP address automatically].
SCG-5608 User Manual Ver. 1.0 3.1.2 Use a Static IP address You can set a static IP address to this product. Figure 3-2 Use a static IP address ⚫ Select the [Use static IP address]. ⚫ Set the [Local IP address], [Subnet mask], [Gateway IP address] and [DNS IP address].
SCG-5608 User Manual Ver. 1.0 3.2 General Figure 3-3 General 3.2.1 Comment This setting is for storing the product description. The maximum setting size of this item is 32 bytes. 3.2.2 TCP/IP ⚫ Connection Mode This item selects the TCP connection method. The default is TCP Server.
SCG-5608 User Manual Ver. 1.0 ⚫ Peer Port This item is to set the destination port number of the device for TCP connection and UDP data transmission. It can be set from 0 to 65535, and the default values are 14700 to 14707.
Page 16
SCG-5608 User Manual Ver. 1.0 ⚫ Option: Secure(TLS) This function implements a secure communication on a TCP session via TLS(v1.2). The counterpart should also support the TLS to implement secure communication by this function. ⚫ Option: TCP No Delay This function does not add a delay of about 40 milliseconds added by default when creating a TCP segment.
SCG-5608 User Manual Ver. 1.0 3.2.4 Serial Port Parameter Option Default Value Serial Type RS232 RS232 Baudrate 1200 ~ 230400 19200 Parity NONE, EVEN, ODD, MARK, SPACE NONE Data Bits 8, 7(required to use a parity bit) Stop Bits 1, 2...
SCG-5608 User Manual Ver. 1.0 3.3 Security Figure 3-4 Security 3.3.1 Password Both ID and password are required to access this product. Note that changing the default password to another is highly recommended for security. The password should be longer than 8 characters.
SCG-5608 User Manual Ver. 1.0 ⚫ Remote access If this item is checked, the product can be connected from the remote network. The port number for this connection is TCP 57457. For security, this item is unchecked by default. 3.3.4 Client ID This is NOT available for this product.
SCG-5608 User Manual Ver. 1.0 Management 4.1 Checking Status This is a function to view the current status of the product. Information in the [Status] window is automatically updated every second. After searching and connecting the product with spFinder, press the [Status] button to display this window. When you open this window, the spFinder connects to the product and keeps the connection until you close the window or time out.
SCG-5608 User Manual Ver. 1.0 ⚫ Product Information List Item Description Product name Product name Pkgware Model name, package version, Firmware version File name File name Uptime Elapsed time since it boots up (day / hour:min:sec) IPv4 Assigned IPv4 address...
SCG-5608 User Manual Ver. 1.0 ⚫ TCP/IP STATE Status Description TCP LISTEN Waiting for a TCP connection TCP CLOSED A TCP session is disconnected A TCP session is connected TCP CONNECTED (shows IP address and port number of connected host)
SCG-5608 User Manual Ver. 1.0 4.2 Changing Firmware New firmware can be released when adding functions or fixing bugs. If you are using old firmware, you can upgrade it to the latest version. Firmware can be upgraded online or manually via spFinder.
SCG-5608 User Manual Ver. 1.0 4.2.2 Manual Upgrade 그림 4-1 Manual Upgrade ⚫ Download a Firmware file to your PC. ⚫ Search and connect to your product by spFinder. ⚫ Click [Advanced] > [Firmware Change] menu. ⚫ Select to [Manual upgrade] on the [Firmware Upgrade] window.
SCG-5608 User Manual Ver. 1.0 4.3 Console The console function analyzes and displays the Modbus frames sent and received by the product. After searching and connecting the product with spFinder, click [Console] in the [Advanced] menu to display the console window. When you open this window, the spFinder connects to the product and keeps the connection until you close the window or time out.
SCG-5608 User Manual Ver. 1.0 ⚫ dump on Pressing this button starts printing communication data out on the network to the Output tab. ⚫ dump off Pressing this button stops printing communication data out on the network to the Output tab.
SCG-5608 User Manual Ver. 1.0 4.4 Export/Import Setting Values The [Export setting values] menu saves all setting values of the product as a file except for the password. The [Import setting values] menu loads setting values from a file which is saved by the [Export setting values] menu. Note that you need to click the [Save] button to apply the setting to your product.
SCG-5608 User Manual Ver. 1.0 4.5 Factory Reset Performing the Factory Reset, you can restore all the settings to the default including the password. Follow the procedure below by checking the status of RUN LED. 1. Press and immediately release the function button.
Technical Support and Warranty 5.1 Technical Support If you have any question regarding operation of the product, visit Customer Support FAQ corner and the message board on Sollae Systems’ web site or send us an email at the following address: ⚫ E-mail: support@eztcp.com...
(including, without limitation, damages for loss of profit, operating cost for commercial interruption, loss of information, or any other financial loss) from the use or inability to use the SIG-5608 even if Sollae Systems Co., Ltd. or its distributors have been informed of such damages.
à leur propriétaire et Fabricant respectif. ⚫ Conditions d’utilisations et limite de responsabilité En aucun cas Sollae Systems Co., Ltd. ou un de ses distributeurs ne pourra être tenu responsable de dommages quels qu'ils soient (intégrant, mais sans limitation, dommages...
Page 32
Sollae Systems Co., Ltd. et ses distributeurs de toute responsabilité et de toute demande de dédommagement. En cas de litige, l'entière responsabilité de Sollae Systems Co., Ltd. et de ses distributeurs vis-à-vis de votre recours durant la période de garantie se limitera exclusivement selon le choix de Sollae Systems Co., Ltd.
Need help?
Do you have a question about the SCG-5608 and is the answer not in the manual?
Questions and answers