FH-EXT
Measuring system
Measuring range [Max]:
Overload protection (of [Max]):
Precision (of [Max]):
Readout [d]:
Test frequency:
Display
Display digit height:
Functions
Data hold function:
Function to set limits:
Obtaining average:
Peak function:
Statistical function:
Environmental conditions
Maximum operating temperature:
Minimum ambient temperature:
Power supply
Charging time:
Input voltage:
n/a:
n/a:
Power supply
Operating time (Backlight off):
Service
DAkkS Calibration certificate
(Pressure):
X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com
X-SENSORS GmbH
Magstadt, Deutschland l Tel: +49 7159/49697-0
info@sensorshop.com l www.sensorshop.com
500 N
150 %
0,005
0,100 N
2000 Hz
1 cm
yes
yes
yes
yes
yes
O
40
C
O
10
C
4 h
100 V - 240 V
CH EURO
Mains adapter external
12 h
963-261
Kompetenz in Messtechnik und Kundenbetreuung
DAkkS Calibration certificate
(Tensile):
DAkkS Calibration certificate
(Tensile/Pressure):
DAkkS Certificate:
ISO calibration certificate:
ISO Calibration certificate (Pressure): 961-261
ISO Calibration certificate (Tensile):
ISO Calibration certificate (Ten-
sile/Pressure):
Category
Brand:
Category:
Product Group:
Packaging & shipping
Delivery:
Dimensions packaging (WxDxH):
Gross weight:
Net weight:
Shipping method:
UN number:
Construction
Cable length:
Dimensions of display device
(WxDxH):
Overall dimensions mounted
(WxDxH):
963-161
963-361
963-161
961-361
961-161
961-361
Sauter
Force gauges
Electronic force-measuring
device
24 h
325 x 185 x 165 mm
2,308 kg
1,137 kg
Parcel service
3496
2,500 m
230 x 66 x 36 mm
230 x 66 x 36 mm
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the FH 10-500 EXT and is the answer not in the manual?

Questions and answers

Summary of Contents for X-SENSORS FH 10-500 EXT

  • Page 1 100 V - 240 V n/a: CH EURO n/a: Mains adapter external Power supply Operating time (Backlight off): 12 h Service DAkkS Calibration certificate 963-261 (Pressure): X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 2 Standard attachments, 5 pieces. M3x 8 screws Sensor Outside Dimensions in mm for the instruments FH 10 EXT up to FH 500 EXT: FH_10-500-BA-e-1213 X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 3 Saves a setting (in SET mode Rechargeable batteries charged simultaneously Rechargeable battery pack for mobile applications: Type: Ni 8.4V / 600 mAh Charging time: approx. 1 hour FH_10-500-BA-e-1213 X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 4 - STAND: Pressing SET three times: sending a signal to the Test Stand to stop its movement (in version U 5.1) Peak-Hold Function (Peak Mode) Please press: Back Light: FH_10-500-BA-e-1213 X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 5: Output Protocol

    SUB-D 9pm Do not use the instrument for dynamic measuring. In the event that small quantities are removed or added to the FH_10-500-BA-e-1213 X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 6 Test weights and instruments can be adjusted quickly and at a reasonable price in KERN’s accredited DKD calibration laboratory (return to national normal). FH_10-500-BA-e-1213 X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 7 9 Attach the Press ZERO weight to the instrument instrument changes to (by hanging) operation mode. Adjustment procedure is finished FH_10-500-BA-e-1213 X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 8 Zeichen beschreibt das Vorzeichen (0 = minus = Druck; 1 = plus = Zug) > oder: 1021.15 bedeutet +21,15 N (Zugkraft) 17.05.2016 FH-SCHNITTSTELLEN BESCHREIBUNG X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 9 (0 = minus = comprehension; 1 = plus = Tension) 1021.15 means +21,15 N 17.05.2016 FH-SCHNITTSTELLEN BESCHREIBUNG X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 10 ASCII Commands to manage the test stands TVM-N Start movement UP ASCII TVM-N Start movement DOWN ASCII TVM-N STOP ASCII 17.05.2016 FH-SCHNITTSTELLEN BESCHREIBUNG X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 11 L x B x H: 76 x 65 x 22 mm Cable length: 2 m 100 mm External Sensor with accessories for push tests. FH_10-500_EXT-dimensions X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 12 Ca. 3m 20 kN 76,2x50,8x28,2 mm M12 x 1,75 50 kN 108x76,2x25,4 mm M18 x 1,5 100 kN 177,8x125,0x50,8 mm M30 x 2,0 FH-ZB-d-1410 X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 13 Ca. 3m 20 kN 76,2x50,8x28,2 mm M12 x 1,75 50 kN 108x76,2x25,4 mm M18 x 1,5 100 kN 177,8x125,0x50,8 mm M30 x 2,0 FH-ZB-d-1410 X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 14 L x B x H: 76 x 65 x 22 mm G: Gewinde M6 Kabellänge: 2 m 100 mm Externer Sensor mit Zubehör für Drucktests. FH-ZB-d-1410 X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...
  • Page 15 76 x 65 x 22 mm G: Thread M6 Cable length: 2 m 100 mm External sensor with accessories for push tests. FH-ZB-d-1410 X-SENSORS GmbH l Steinbrechstr. 9, 71106 – Magstadt, Deutschland l Tel: +49 7159/49697-0 l info@sensorshop.com l www.sensorshop.com...